70 research outputs found
Levosimendan Administration in Limb Ischemia: Multicomponent Signaling Serving Kidney Protection
AIMS AND OBJECTIVES: Acute renal failure is a severe complication of lower extremity major arterial reconstructions, which could even be fatal. Levosimendan is a dual-acting positive inotropic and vasodilatory agent, which is suspected to have protective effects against cardiac ischemia. However, there is no data available on lower limb or remote organ ischemic injuries therefore the aim of the study was to investigate the effect of levosimendan on lower limb ischemia-reperfusion injury and the corollary renal dysfunction. METHODS: Male Wistar rats underwent 180 min bilateral lower limb ischemia followed by 4 or 24 hours of reperfusion. Intravenous Levosimendan was administered continuously (0.2mug/bwkg/min) throughout the whole course of ischemia and the first 3h of reperfusion. Results were compared with sham-operated and ischemia-reperfusion groups. Hemodynamic monitoring was performed by invasive arterial blood pressure measurement. Kidney and lower limb muscle microcirculation was registered by a laser Doppler flowmeter. After 4h and 24h of reperfusion, serum, urine and histological samples were collected. RESULTS: Systemic hemodynamic parameters and microcirculation of kidney and the lower limb significantly improved in the Levosimendan treated group. Muscle viability was significantly preserved 4 and 24 hours after reperfusion. At the same time, renal functional laboratory tests and kidney histology demonstrated significantly less expressive kidney injury in Levosimendan groups. TNF-alpha levels were significantly less elevated in the Levosimendan group 4 hours after reperfusion. CONCLUSION: The results claim a protective role for Levosimendan administration during major vascular surgeries to prevent renal complications
Update of complications and functional outcome of the ileo-pouch anal anastomosis: overview of evidence and meta-analysis of 96 observational studies
Item does not contain fulltextOBJECTIVE: The objective of this study is to provide a comprehensive update of the outcome of the ileo-pouch anal anastomosis (IPAA). DATA SOURCES: An extensive search in PubMed, EMBASE, and The Cochrane Library was conducted. STUDY SELECTION AND DATA EXTRACTION: All studies published after 2000 reporting on complications or functional outcome after a primary open IPAA procedure for UC or FAP were selected. Study characteristics, functional outcome, and complications were extracted. DATA SYNTHESIS: A review with similar methodology conducted 10 years earlier was used to evaluate developments in outcome over time. Pooled estimates were compared using a random-effects logistic meta-analyzing technique. Analyses focusing on the effect of time of study conductance, centralization, and variation in surgical techniques were performed. RESULTS: Fifty-three studies including 14,966 patients were included. Pooled rates of pouch failure and pelvic sepsis were 4.3% (95% CI, 3.5-6.3) and 7.5% (95% CI 6.1-9.1), respectively. Compared to studies published before 2000, a reduction of 2.5% was observed in the pouch failure rate (p = 0.0038). Analysis on the effect of the time of study conductance confirmed a decline in pouch failure. Functional outcome remained stable over time, with a 24-h defecation frequency of 5.9 (95% CI, 5.0-6.9). Technical surgery aspects did not have an important effect on outcome. CONCLUSION: This review provides up to date outcome estimates of the IPAA procedure that can be useful as reference values for practice and research. It is also shows a reduction in pouch failure over time.1 juli 201
Attenuation of Skeletal Muscle and Renal Injury to the Lower Limb following Ischemia-Reperfusion Using mPTP Inhibitor NIM-811.
INTRODUCTION: Operation on the infrarenal aorta and large arteries of the lower extremities may cause rhabdomyolysis of the skeletal muscle, which in turn may induce remote kidney injury. NIM-811 (N-metyl-4-isoleucine-cyclosporine) is a mitochondria specific drug, which can prevent ischemic-reperfusion (IR) injury, by inhibiting mitochondrial permeability transition pores (mPTP). OBJECTIVES: Our aim was to reduce damages in the skeletal muscle and the kidney after IR of the lower limb with NIM-811. MATERIALS AND METHODS: Wistar rats underwent 180 minutes of bilateral lower limb ischemia and 240 minutes of reperfusion. Four animal groups were formed called Sham (receiving vehicle and sham surgery), NIM-Sham (receiving NIM-811 and sham surgery), IR (receiving vehicle and surgery), and NIM-IR (receiving NIM-811 and surgery). Serum, urine and histological samples were taken at the end of reperfusion. NADH-tetrazolium staining, muscle Wet/Dry (W/D) ratio calculations, laser Doppler-flowmetry (LDF) and mean arterial pressure (MAP) monitoring were performed. Renal peroxynitrite concentration, serum TNF-alpha and IL-6 levels were measured. RESULTS: Less significant histopathological changes were observable in the NIM-IR group as compared with the IR group. Serum K+ and necroenzyme levels were significantly lower in the NIM-IR group than in the IR group (LDH: p<0.001; CK: p<0.001; K+: p = 0.017). Muscle mitochondrial viability proved to be significantly higher (p = 0.001) and renal function parameters were significantly better (creatinine: p = 0.016; FENa: p<0.001) in the NIM-IR group in comparison to the IR group. Serum TNF-alpha and IL-6 levels were significantly lower (TNF-alpha: p = 0.003, IL-6: p = 0.040) as well as W/D ratio and peroxynitrite concentration were significantly lower (p = 0.014; p<0.001) in the NIM-IR group than in the IR group. CONCLUSION: NIM-811 could have the potential of reducing rhabdomyolysis and impairment of the kidney after lower limb IR injury
Search for Ultra-high-energy Photons from Gravitational Wave Sources with the Pierre Auger Observatory
A search for time-directional coincidences of ultra-high-energy (UHE) photons above 10 EeV with gravitational wave (GW) events from the LIGO/Virgo runs O1 to O3 is conducted with the Pierre Auger Observatory. Due to the distinctive properties of photon interactions and to the background expected from hadronic showers, a subset of the most interesting GW events is selected based on their localization quality and distance. Time periods of 1000 s around and 1 day after the GW events are analyzed. No coincidences are observed. Upper limits on the UHE photon fluence from a GW event are derived that are typically at & SIM;7 MeV cm(-2) (time period 1000 s) and & SIM;35 MeV cm(-2) (time period 1 day). Due to the proximity of the binary neutron star merger GW170817, the energy of the source transferred into UHE photons above 40 EeV is constrained to be less than 20% of its total GW energy. These are the first limits on UHE photons from GW sources
Arrival Directions of Cosmic Rays above 32 EeV from Phase One of the Pierre Auger Observatory
A promising energy range to look for angular correlations between cosmic rays of extragalactic origin and their sources is at the highest energies, above a few tens of EeV (1 EeV equivalent to 10^(18) eV). Despite the flux of these particles being extremely low, the area of similar to 3000 km^(2) covered at the Pierre Auger Observatory, and the 17 yr data-taking period of the Phase 1 of its operations, have enabled us to measure the arrival directions of more than 2600 ultra-high-energy cosmic rays above 32 EeV. We publish this data set, the largest available at such energies from an integrated exposure of 122,000 km^(2) sr yr, and search it for anisotropies over the 3.4 pi steradians covered with the Observatory. Evidence for a deviation in excess of isotropy at intermediate angular scales, with similar to 15 degrees Gaussian spread or similar to 25 degrees top-hat radius, is obtained at the 4 sigma significance level for cosmic-ray energies above similar to 40 EeV
Searches for Ultra-High-Energy Photons at the Pierre Auger Observatory
The Pierre Auger Observatory, which is the largest air-shower experiment in the world, offers unprecedented exposure to neutral particles at the highest energies. Since the start of data collection more than 18 years ago, various searches for ultra-high-energy (UHE, E greater than or similar to 10^(17) eV) photons have been performed, either for a diffuse flux of UHE photons, for point sources of UHE photons or for UHE photons associated with transient events such as gravitational wave events. In the present paper, we summarize these searches and review the current results obtained using the wealth of data collected by the Pierre Auger Observatory
- …