3 research outputs found

    Field suitability and diagnostic accuracy of the Biocentric® open real-time PCR platform for plasma-based HIV viral load quantification in Swaziland

    No full text
    Abstract Background Viral load (VL) testing is being scaled up in resource-limited settings. However, not all commercially available VL testing methods have been evaluated under field conditions. This study is one of a few to evaluate the Biocentric platform for VL quantification in routine practice in Sub-Saharan Africa. Methods Venous blood specimens were obtained from patients eligible for VL testing at two health facilities in Swaziland from October 2016 to March 2017. Samples were centrifuged at two laboratories (LAB-1, LAB-2) to obtain paired plasma specimens for VL quantification with the national reference method and on the Biocentric platform. Agreement (correlation, Bland–Altman) and accuracy (sensitivity, specificity) indicators were calculated at the VL thresholds of 416 (2.62 log10) and 1000 (3.0 log10) copies/mL. Leftover samples from patients with discordant VL results were re-quantified and accuracy indicators recalculated. Logistic regression was used to compare laboratory performance. Results A total of 364 paired plasma samples (LAB-1: n = 198; LAB-2: n = 166) were successfully tested using both methods. The correlation was high (R = 0.82, p < 0.01), and the Bland–Altman analysis showed a minimal mean difference (− 0.03 log10 copies/mL; 95% CI: -1.15 to 1.08). At the clinical threshold level of 3.0 log10 copies/mL, the sensitivity was 88.6% (95% CI: 78.7 to 94.9) and the specificity was 98.3% (95% CI: 96.1 to 99.4). Sensitivity was higher in LAB-1 (100%; 95% CI: 71.5 to 100) than in LAB-2 (86.4%; 95% CI: 75.0 to 94.0). Most upward (n = 8, 2.2%) and downward (n = 11, 3.0%) misclassifications occurred at the 2.62 log threshold, with LAB-2 having a 16 (95% CI: 2.26 to 113.27; p = 0.006) times higher odds of downward misclassification. After retesting of discordant leftover samples (n = 17), overall sensitivity increased to 93.5% (95% CI: 85.5 to 97.9) and 97.1% (95% CI: 90.1 to 99.7) at the 2.62 and 3.0 thresholds, and specificity increased to 98.6% (95% CI: 96.5 to 99.6) and 99.0% (95% CI: 97.0 to 99.8) respectively. Conclusions The test characteristics of the Biocentric platform were overall comparable to the national reference method for VL quantification. One laboratory tended to misclassify VL results downwards, likely owing to unmet training needs and lack of previous hands-on practice

    Predicting, Diagnosing, and Treating Acute and Early HIV Infection in a Public Sector Facility in Eswatini

    No full text
    Background: The lack of acute and early HIV infection (AEHI) diagnosis and care contributes to high HIV incidence in resource-limited settings. We aimed to assess the yield of AEHI, predict and diagnose AEHI, and describe AEHI care outcomes in a public sector setting in Eswatini. Setting: This study was conducted in Nhlangano outpatient department from March 2019 to March 2020. Methods: Adults at risk of AEHI underwent diagnostic testing for AEHI with the quantitative Xpert HIV-1 viral load (VL) assay. AEHI was defined as the detection of HIV-1 VL on Xpert and either an HIV-seronegative or HIV-serodiscordant third-generation antibody-based rapid diagnostic test (RDT) result. First, the cross-sectional analysis obtained the yield of AEHI and established a predictor risk score for the prediction of AEHI using Lasso logistic regression. Second, diagnostic accuracy statistics described the ability of the fourth-generation antibody/p24 antigen-based Alere HIV-Combo RDT to diagnose AEHI (vs Xpert VL testing). Third, we described acute HIV infection care outcomes of AEHI-positive patients using survival analysis. Results: Of 795 HIV-seronegative/HIV-serodiscordant outpatients recruited, 30 (3.8%, 95% confidence interval: 2.6% to 5.3%) had AEHI. The predictor risk score contained several factors (HIV-serodiscordant RDT, women, feeling at risk of HIV, swollen glands, and fatigue) and had sensitivity and specificity of 83.3% and 65.8%, respectively, to predict AEHI. The HIV-Combo RDT had sensitivity and specificity of 86.2% and 99.9%, respectively, to diagnose AEHI. Of 30 AEHI-positive patients, the 1-month cumulative treatment initiation was 74% (95% confidence interval: 57% to 88%), and the 3-month viral suppression (&lt;1000 copies/mL) was 87% (67% to 98%). Conclusion: AEHI diagnosis and care seem possible in resource-limited settings.</p
    corecore