6 research outputs found

    Serum creatinine and cystatin C‐based estimates of glomerular filtration rate are misleading in acute heart failure

    Get PDF
    Aims: We aimed to test whether the endogenous filtration markers serum creatinine or cystatin C and equation-based estimates of glomerular filtration rate (GFR) based on these markers appropriately reflect changes of measured GFR in patients with acute heart failure. Methods: In this prospective cohort study of 50 hospitalized acute heart failure patients undergoing decongestive therapy, we applied an intravenous visible fluorescent injectate (VFI), consisting of a low molecular weight component to measure GFR and a high molecular weight component to correct for measured plasma volume. Thirty-eight patients had two sequential GFR measurements 48 h apart. The co-primary endpoints of the study were safety of VFI and plasma stability of the high molecular weight component. A key secondary endpoint was to compare changes in measured GFR (mGFR) to changes of serum creatinine, cystatin C and estimated GFR. Results: VFI-based GFR measurements were safe and consistent with plasma stability of the high molecular weight component and glomerular filtration of the low molecular weight component. Filtration marker-based point estimates of GFR, when compared with mGFR, provided only moderate correlation (Pearson's r, range 0.80-0.88, depending on equation used), precision (r(2), range 0.65-0.78) and accuracy (56%-74% of estimates scored within 30% of mGFR). Correlations of 48-h changes GFR estimates and changes of mGFR were significant (P 15% decrease in mGFR. Conclusions: In patients hospitalized for acute heart failure, serum creatinine- and cystatin C-based predictions performed poorly in detecting actual changes of GFR. These data challenge current clinical strategies to evaluate dynamics of kidney function in acute heart failure

    Discordance between estimated and measured changes in plasma volume among patients with acute heart failure

    Get PDF
    Aims: In acute heart failure (AHF), changes of venous haemoglobin (Hb) concentrations, haematocrit (Hct), and estimated plasma volume (ePV) have been proposed as surrogates of decongestion. These estimates are based on the theoretical assumptions that changes of Hb concentrations and Hct are driven by the intravascular volume status and that the intravascular Hb pool remains stable. The objective of this study was to assess the relationship of changes of measured plasma volume (mPV) with changes of Hb, Hct, and ePV in AHF. Methods and results: We studied 36 AHF patients, who received two sequential assessments of mPV, measured red cell volume (mRCV) and measured total blood volume (mTBV) (48 h apart), during the course of diuretic therapy using a novel visible fluorescent injectate (VFI) technique based on the indicator dilution principle. Changes of ePV were calculated based on the Kaplan-Hakim or Strauss formula. AHF patients receiving diuretics (median intravenous furosemide equivalent 160 mg/48 h) displayed a wide range of changes of mPV (-25.4% to +37.0%). Changes in mPV were not significantly correlated with changes of Hb concentration [Pearson's r (r) = -0.241, P = 0.157], Hct (r = -0.307, P = 0.069), ePV(Kaplan-Hakim) (r = 0.228, P = 0.182), or ePV(strauss) (r = 0.237, P = 0.163). In contrast to theoretical assumptions, changes of mTBV were poorly correlated with changes of Hb concentrations and some patients displayed unanticipated variability of mRCV, suggesting an unstable intravascular red cell pool. Conclusions: Changes of Hb or Hct were not reflective of directly measured changes of intravascular volume status in AHF patients. Basing clinical assessment of decongestion on changes of Hb or Hct may misguide clinical decision-making on an individual patient level

    The role of neuromuscular ultrasound in diagnostics of peripheral neuropathies induced by cytostatic agents or immunotherapies

    No full text
    Abstract A relevant number of cancer patients who receive potentially neurotoxic cytostatic agents develop a chemotherapy-induced peripheral neuropathy over time. Moreover, the increasing use of immunotherapies and targeted agents leads to a raising awareness of treatment-associated peripheral neurotoxicity, e.g., axonal and demyelinating neuropathies such as Guillain–Barré-like syndromes. To date, the differentiation of these phenomena from concurrent neurological co-morbidities or (para-)neoplastic nerve affection as well as their longitudinal monitoring remain challenging. Neuromuscular ultrasound (NMUS) is an established diagnostic tool for peripheral neuropathies. Performed by specialized neurologists, it completes clinical and neurophysiological diagnostics especially in differentiation of axonal and demyelinating neuropathies. No generally approved biomarkers of treatment-induced peripheral neurotoxicity have been established so far. NMUS might significantly extend the repertoire of diagnostic and neuromonitoring methods in this growing patient group in short term. In this article, we present enlargements of the dorsal roots both in cytostatic and in immunotherapy-induced neurotoxicity for the first time. We discuss related literature regarding new integrative applications of NMUS for cancer patients by reference to two representative case studies. Moreover, we demonstrate the integration of NMUS in a diagnostic algorithm for suspected peripheral neurotoxicity independently of a certain cancer treatment regimen emphasizing the emerging potential of NMUS for clinical routine in this interdisciplinary field and prospective clinical trials

    Discordance between estimated and measured changes in plasma volume among patients with acute heart failure

    Get PDF
    Aims: In acute heart failure (AHF), changes of venous haemoglobin (Hb) concentrations, haematocrit (Hct), and estimated plasma volume (ePV) have been proposed as surrogates of decongestion. These estimates are based on the theoretical assumptions that changes of Hb concentrations and Hct are driven by the intravascular volume status and that the intravascular Hb pool remains stable. The objective of this study was to assess the relationship of changes of measured plasma volume (mPV) with changes of Hb, Hct, and ePV in AHF. Methods and results: We studied 36 AHF patients, who received two sequential assessments of mPV, measured red cell volume (mRCV) and measured total blood volume (mTBV) (48 h apart), during the course of diuretic therapy using a novel visible fluorescent injectate (VFI) technique based on the indicator dilution principle. Changes of ePV were calculated based on the Kaplan-Hakim or Strauss formula. AHF patients receiving diuretics (median intravenous furosemide equivalent 160 mg/48 h) displayed a wide range of changes of mPV (-25.4% to +37.0%). Changes in mPV were not significantly correlated with changes of Hb concentration [Pearson\u27s r (r) = -0.241, P = 0.157], Hct (r = -0.307, P = 0.069), ePVKaplan-Hakim (r = 0.228, P = 0.182), or ePVStrauss (r = 0.237, P = 0.163). In contrast to theoretical assumptions, changes of mTBV were poorly correlated with changes of Hb concentrations and some patients displayed unanticipated variability of mRCV, suggesting an unstable intravascular red cell pool. Conclusions: Changes of Hb or Hct were not reflective of directly measured changes of intravascular volume status in AHF patients. Basing clinical assessment of decongestion on changes of Hb or Hct may misguide clinical decision-making on an individual patient level

    Serum creatinine and cystatin C-based estimates of glomerular filtration rate are misleading in acute heart failure

    No full text
    AIMS: We aimed to test whether the endogenous filtration markers serum creatinine or cystatin C and equation-based estimates of glomerular filtration rate (GFR) based on these markers appropriately reflect changes of measured GFR in patients with acute heart failure. METHODS: In this prospective cohort study of 50 hospitalized acute heart failure patients undergoing decongestive therapy, we applied an intravenous visible fluorescent injectate (VFI), consisting of a low molecular weight component to measure GFR and a high molecular weight component to correct for measured plasma volume. Thirty-eight patients had two sequential GFR measurements 48 h apart. The co-primary endpoints of the study were safety of VFI and plasma stability of the high molecular weight component. A key secondary endpoint was to compare changes in measured GFR (mGFR) to changes of serum creatinine, cystatin C and estimated GFR. RESULTS: VFI-based GFR measurements were safe and consistent with plasma stability of the high molecular weight component and glomerular filtration of the low molecular weight component. Filtration marker-based point estimates of GFR, when compared with mGFR, provided only moderate correlation (Pearson\u27s r, range 0.80-0.88, depending on equation used), precision (r2 , range 0.65-0.78) and accuracy (56%-74% of estimates scored within 30% of mGFR). Correlations of 48-h changes GFR estimates and changes of mGFR were significant (P \u3c 0.05) but weak (Pearson\u27s r, range 0.35-0.39). Observed decreases of eGFR by more than 15% had a low sensitivity (range 38%-46%, depending on equation used) in detecting true worsening mGFR, defined by a \u3e15% decrease in mGFR. CONCLUSIONS: In patients hospitalized for acute heart failure, serum creatinine- and cystatin C-based predictions performed poorly in detecting actual changes of GFR. These data challenge current clinical strategies to evaluate dynamics of kidney function in acute heart failure
    corecore