74 research outputs found

    Penetration of topical diclofenac into synovial tissue and fluid of osteoarthritic knees: a multicenter, randomized, placebo-controlled, pharmacokinetic study

    Get PDF
    Funder: GSK Consumer Healthcare S.A., Nyon, SwitzerlandBackground:: Topical diclofenac, a nonsteroidal anti-inflammatory drug, has proven efficacy and safety in the management of osteoarthritis pain. We investigated penetration of topical diclofenac into knee synovial tissue and fluid (primary objective) and evaluated relative exposure in the knee versus plasma (secondary objective). Methods:: In this phase I, double-blind, multicenter study, patients scheduled for arthroplasty for end-stage knee osteoarthritis were randomly assigned 2:1 to 4 g diclofenac diethylamine 2.32% w/w gel (92.8 mg diclofenac diethylamine, equivalent to 74.4 mg diclofenac, per application) or placebo gel, applied to the affected knee by a trained nurse/designee every 12 h for 7 days before surgery. Diclofenac concentrations were measured in synovial tissue, synovial fluid and plasma from samples obtained during surgery ⩾12 h after last application. Treatment-emergent adverse events (TEAEs) were evaluated. Results:: Evaluable synovial tissue or fluid samples were obtained from 45 (diclofenac n = 29; placebo n = 16) of 47 patients. All diclofenac-treated participants had measurable diclofenac concentrations in synovial tissue [geometric mean 1.57 (95% confidence interval (CI) 1.12, 2.20) ng/g] and fluid [geometric mean 2.27 (95% CI 1.87, 2.76) ng/ml] ⩾12 h after the last dose. Geometric mean (95% CI) ratio of diclofenac in synovial tissue:plasma was 0.32 (0.23, 0.45) and in synovial fluid:plasma was 0.46 (0.40, 0.54). TEAE rates were similar for diclofenac (55.2%) and placebo (58.8%); none were treatment related. Conclusions:: Topical diclofenac diethylamine 2.32% w/w gel penetrated into the osteoarthritic knee after repeated application and remained detectable in synovial tissue and fluid at the end of the final 12 h dosing cycle

    Reproducibility of different screening classifications in ultrasonography of the newborn hip

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ultrasonography of the hip has gained wide acceptance as a primary method for diagnosis, screening and treatment monitoring of developmental hip dysplasia in infants. The aim of the study was to examine the degree of concordance of two objective classifications of hip morphology and subjective parameters by three investigators with different levels of experience.</p> <p>Methods</p> <p>In 207 consecutive newborns (101 boys; 106 girls) the following parameters were assessed: bony roof angle (α-angle) and cartilage roof angle (β-angle) according to Graf's basic standard method, "femoral head coverage" (FHC) as described by Terjesen, shape of the bony roof and position of the cartilaginous roof. Both hips were measured twice by each investigator with a 7.5 MHz linear transducer (SONOLINE G60S<sup>® </sup>ultrasound system, SIEMENS, Erlangen, Germany).</p> <p>Results</p> <p>Mean kappa-coefficients for the subjective parameters shape of the bony roof (0.97) and position of the cartilaginous roof (1.0) demonstrated high intra-observer reproducibility. Best results were achieved for α-angle, followed by β-angle and finally FHC. With respect to limits of agreement, inter-observer reproducibility was calculated less precisely.</p> <p>Conclusions</p> <p>Higher measurement differences were evaluated more in objective scorings. Those variations were observed by every investigator irrespective of level of experience.</p

    Facharzt für Orthopädie und Unfallchirurgie - Zusatzweiterbildungen

    No full text

    Orthopädie

    No full text

    Effizienz der Kyphoplastie bei Osteoporose.

    No full text

    Intravertebrale Druckverhältnisse während der Kyphoplastie und Vertebroplastie

    No full text

    Hypervaskularisation als Ursache des diskogenen Schmerzes?

    No full text

    Aktueller Stand der Zemententfernungstechniken bei Hüft-Revisions-Operationen

    No full text
    corecore