34 research outputs found

    Особенности личности страдающих гашишной зависимостью мужчин

    Get PDF
    Рассмотрен личностный профиль мужчин, страдающих гашишной зависимостью. Показано, что длительное употребление наркотика ведет к формированию шизотипической личности.The personality profile of men with hashish addiction is described. Prolonged use of drugs is shown to cause formation of schizothymic personality

    Trait anxiety mediates the effect of stress exposure on post-traumatic stress disorder and depression risk in cardiac surgery patients

    Full text link
    BACKGROUND: Post-traumatic stress disorder (PTSD) and depression are common after cardiac surgery. Lifetime stress exposure and personality traits may influence the development of these psychiatric conditions. METHODS: Self-reported rates of PTSD and depression and potential determinants (i.e., trait anxiety and stress exposure) were established 1.5 to 4 years after cardiac surgery. Data was available for 1125 out of 1244 (90.4%) participants. Multivariable linear regressions were conducted to investigate mediating and/or moderating effects of trait anxiety on the relationship between stress exposure, and PTSD and depression. Pre-planned subgroup analyses were performed for both sexes. RESULTS: PTSD and depression symptoms were present in 10.2% and 13.1% of the participants, respectively. Trait anxiety was a full mediator of the association between stress exposure and depression in both the total cohort and female and male subgroups. Moreover, trait anxiety partially mediated the relationship between stress exposure and PTSD in the full cohort and the male subgroup, whereas trait anxiety fully mediated this relationship in female patients. Trait anxiety did not play a moderating role in the total patient sample, nor after stratification on gender. LIMITATIONS: The unequal distribution of male (78%) and female patients (22%) might limit the generalizability of our findings. Furthermore, risk factors were investigated retrospectively and with variable follow-up time. CONCLUSIONS: In cardiac surgery patients, trait anxiety was found to be an important mediator of postoperative PTSD and depression. Prospective research is necessary to verify whether these factors are reliable screening measures of individuals' vulnerability for psychopathology development after cardiac surgery

    Administration of fibrinogen concentrate during cardiac surgery - Reply

    No full text

    Accuracy, Precision, and Trending Ability of Uncalibrated Arterial Pressure Waveform Analysis of Cardiac Output in Patients With Impaired Left Ventricular Function : A Prospective, Observational Study

    No full text
    OBJECTIVES: Uncalibrated arterial waveform analysis provides minimally invasive and continuous measurement of cardiac output (CO). This technique could be of great value in patients with impaired left ventricular function, but the validity in these patients is not well established. The aim of this study was to investigate the accuracy, precision, and trending ability of uncalibrated arterial waveform analysis of cardiac output in patients with impaired left ventricular function. DESIGN: Prospective, observational, method-comparison study. SETTING: Nonuniversity teaching hospital, single center. PARTICIPANTS: The study included 22 patients with a left ventricular ejection fraction of 40% or less undergoing elective coronary artery bypass grafting. INTERVENTIONS: In the period between induction of anesthesia and sternotomy, CO was measured using the FloTrac/Vigileo system (third-generation software) and intermittent pulmonary artery thermodilution before and after volume loading. MEASUREMENTS AND MAIN RESULTS: Accuracy and precision as determined using Bland-Altman analysis revealed a bias of -0.7 L/min, limits of agreement of -2.9 to 1.5 L/min, and a mean error of 55% for pooled data. Proportional bias and spread were present, indicating that bias and limits of agreement were underestimated for high CO values. Trending ability was assessed using 4-quadrant analysis, which revealed a concordance of 86%. Concordance from a clinical perspective was 36%. Polar plot analysis showed an angular bias of 13° degrees, with radial limits of agreement of -55° to 51°. Polar concordance at±30° was 50%. CONCLUSIONS: Arterial waveform analysis of cardiac output and pulmonary artery thermodilution cardiac output were not interchangeable in patients with impaired left ventricular function

    Fibrinogen Concentrate Therapy in Complex Cardiac Surgery

    No full text
    <p>Objectives: Fibrinogen concentrate increasingly is used to treat coagulopathic bleeding in cardiac surgery although its effectiveness and safety have not been shown. The authors conducted a cohort study to quantify the effects of fibrinogen concentrate on postoperative blood loss and transfusion and the occurrence of adverse clinical events in complex cardiac surgery patients.</p><p>Design: A cohort analysis using prospectively collected data.</p><p>Setting: A teaching hospital.</p><p>Participants: One thousand seventy-five patients who underwent complex cardiac surgery in the years 2007 to 2010.</p><p>Intervention: A nonrandomized intervention with fibrinogen concentrate during complex cardiac surgery.</p><p>Measurements and Main Results: Of the 1,075 patients, 264 (25%) received fibrinogen concentrate during surgery (median dose = 2 g). In the adjusted analysis, the effect of fibrinogen concentrate on blood loss and transfusion in the intensive care unit showed a ratio of geometric means of 1.02(0.91-1.14) and an odds ratio of 1.14 (0.83-1.56), respectively. For the risk of 30-day mortality, myocardial infarction, cerebrovascular accident/transient ischemic attack, renal insufficiency/failure, total infections, and prolonged mechanical ventilation the adjusted odds ratios were 0.96 (0.481.92), 1.10 (0.53-2.27), 1.16 (0.50-2.72), 0.62 (0.29-1.32), 1.18 (0.72-1.95), and 1.44 (0.83-2.49), respectively.</p><p>Conclusions: Fibrinogen concentrate infusion during surgery did not reduce postoperative blood loss and transfusion, and no increased risk for clinical adverse events was measured. The lower doses and the relatively late intervention with fibrinogen concentrate might have attenuated its hemostatic effect. This study reports the initial clinical use of fibrinogen concentrate in complex cardiac surgery. A randomized clinical trial has been initiated to investigate the hemostatic role of fibrinogen concentrate in cardiac surgery. (C) 2012 Elsevier Inc. All rights reserved.</p>

    Pre- and Postoperative Accuracy and Safety of a Real-Time Continuous Glucose Monitoring System in Cardiac Surgical Patients: A Randomized Pilot Study

    Get PDF
    Background: Our objective was to evaluate the accuracy and safety of a real-time (RT) continuous glucose monitoring system (CGMS) in patients before and after cardiothoracic surgery and to investigate whether activation of the alarm function of the RT-CGMS had an effect on glucose control. Methods: Patients scheduled for elective cardiothoracic procedures, without a history of insulin-requiring diabetes, were perioperatively monitored with RT-CGMS for 72 h and were randomized into two groups: with or without the alarm function (set at 4 and 10 mmol/L) of the device activated. Sensor values were compared with capillary, arterial, and venous blood glucose values. Percentages of time spent in various glucose ranges were compared between groups. Results: There were no adverse effects of the RT-CGMS. Of the 1,001 sensor value comparisons with capillary or arterial measurements, 96.6% fell within Clarke Error Grid zones A and B, with relative absolute differences ranging from 15% (preoperative period) to 12% (intensive care unit period) to 14% (postoperative period on the ward). Seventeen (7.9%) arterial and 16 (2.0%) capillary comparisons fell within zone D or E. Whether or not the alarm function, as used in this pilot study, was activated did not affect time spent in different glucose ranges. Conclusions: Although the RT-CGMS is safe and accurate according to accepted standards, there are still small aberrations, which in our opinion preclude unlimited use in its present form in a clinical setting. The effect of the alarm function at different glucose levels remains to be investigated

    A Comparison of Measures of Endothelial Function in Patients with Peripheral Arterial Disease and Age and Gender Matched Controls

    Get PDF
    This study compared flow-mediated dilatation (FMD), peripheral artery tonometry (PAT), and serum nitric oxide (NO) measures of endothelial function in patients with peripheral artery disease (PAD) against age/gender matched controls. 25 patients (mean age: 72.4 years, M : F 18 : 7) with established PAD and an age/gender matched group of 25 healthy controls (mean age: 72.4 years, M : F 18 : 7) were studied. Endothelial function was measured using the % FMD, reactive hyperemia index (RHI) using PAT and serum NO (μmol). Difference for each method between PAD and control patients and correlation between the methods were investigated. FMD and RHI were lower in patients with PAD (median FMD for PAD = 2.16% versus control = 3.77%, p=0.034 and median RHI in PAD = 1.64 versus control = 1.92, p=0.005). NO levels were not significantly different between the groups (PAD median = 7.70 μmol, control median = 13.05 μmol, p=0.662). These results were obtained in elderly patients and cannot be extrapolated to younger individuals. FMD and PAT both demonstrated a lower hyperaemic response in patients with PAD; however, FMD results in PAD patients were unequivocally reduced whereas half the PAD patients had RHI values above the established threshold for endothelial dysfunction. This suggests that FMD is a more appropriate method for the measurement of NO-mediated endothelial function

    A Protocol for Diagnosis and Management of Aortic Atherosclerosis in Cardiac Surgery Patients

    Get PDF
    In patients undergoing cardiac surgery, use of perioperative screening for aortic atherosclerosis with modified TEE (A-View method) was associated with lower postoperative mortality, but not stroke, as compared to patients operated on without such screening. At the time of clinical implementation and validation, we did not yet standardize the indications for modified TEE and the changes in patient management in the presence of aortic atherosclerosis. Therefore, we designed a protocol, which combined the diagnosis of atherosclerosis of thoracic aorta and the subsequent considerations with respect to the intraoperative management and provides a systematic approach to reduce the risk of cerebral complications
    corecore