    A Surface-Integrated Sensor Network for Personalized Multifunctional Catheters*

    Get PDF
    Augmenting the sensing/actuating capabilities of multifunctional catheters used for minimally invasive interventions has been fostered by the reduction of transducers’ sizes. However, increasing the number of transducers to benefit from the entire catheter surface is challenging due to the number of connections and/or the required integrated circuits dedicated for multiplexing the transducer signals. Modular concepts enabling personalized catheters are lacking, at all. In this work, we investigated the feasibility of a simple and daisy-chainable transducer node network for active catheters, which overcomes these limitations. Sequentially accessible nodes enabling analog interaction (including signal buffering) with transducers were designed and fabricated using miniature components suited for catheter integration. The effective sampling rate (ESR) per node for acquiring bio-signals from 10 nodes was examined for various signal-to-noise ratios. Thanks to the low circuit complexity, an ESR up to 20 kHz was achieved, which is high enough for many bio-signals.Clinical relevance— Typical daisy-chaining features, namely theoretically indefinite node extension and simple reconfiguration facilitates modularization of the catheter design. The proposed network consequently ensures application and patient-specific requirements while incorporating transducer functions over the entire catheter surface, both may improve minimally invasive interventions

    High-resolution esophageal long-term ECG allows detailed atrial wave morphology analysis in case of atrial ectopic beats

    Get PDF
    Detection of arrhythmic atrial beats in surface ECGs can be challenging when they are masked by the R or T wave, or do not affect the RR-interval. Here, we present a solution using a high-resolution esophageal long-term ECG that offers a detailed view on the atrial electrical activity. The recorded ECG shows atrial ectopic beats with long coupling intervals, which can only be successfully classified using additional morphology criteria. Esophageal high-resolution ECGs provide this information, whereas surface long-term ECGs show poor atrial signal quality. This new method is a promising tool for the long-term rhythm monitoring with software-based automatic classification of atrial beat

    Respiratory rate estimation from multi-channel signals using auto-regulated adaptive extended Kalman filter

    Get PDF
    Background: Respiration rate (RR) is a major cause for false alarms in intensive care units (ICU) and is primarily impaired by the artifact prone signals from skin-attached electrodes. Catheter-integrated esophageal electrodes are an alternative source for multi-channel physiological signals from multiple organs such as the heart and the diaphragm. Nonlinear estimation and sensor fusion are promising techniques for extracting the respiratory activity from such multi-component signals, however, pathologic breathing patterns with rapid RR changes typically observed in patient populations such as premature infants, pose significant challenges. Methods: We developed an auto-regulated adaptive extended Kalman filter (AA-EKF), which iteratively adapts the system model and the noise parameters based on the respiratory pattern. AA-EKF was tested on neonatal esophageal observations (NEO), and also on simulated multi-components signals created using waveforms in CapnoBase and ETNA databases. Results: AA-EKF derived RR (RRAA-EKF) from NEO had lower median (inter-quartile range) error of 0.1 (10.6) breaths per minute (bpm) compared to contemporary neonatal ICU monitors (RRNICU): −3.8 (15.7) bpm (p <0.001). RRAA-EKF error of −0.2 (3.2) bpm was achieved for ETNA wave forms and a bias (95% LOA) of 0.1 (−5.6, 5.9) in breath count. Mean absolute error (MAE) of RRAA-EKF with Capnobase waveforms, as median (inter-quartile range), at 0.3 (0.2) bpm was comparable to the literature reported values. Discussion: The auto-regulated approach allows RR estimation on a broad set of clinical data without requiring extensive patient specific adjustments. Causality and fast response times of EKF based algorithms makes the AA-EKF suitable for bedside monitoring in the ICU setting

    Analysis of Chemical Warfare Agents at the NC Laboratory Spiez

    Get PDF
    The group for chemical analysis and verification at the NC Laboratory Spiez engages in the analysis of chemical warfare agents and related compounds in the frame of international chemical disarmament. Its area of work and instrumentation are described together with the analysis of a sample taken in Iraq after the Gulf War

    A miniaturized endocardial electromagnetic energy harvester for leadless cardiac pacemakers

    Get PDF
    Life expectancy of contemporary cardiac pacemakers is limited due to the use of an internal primary battery. Repeated device replacement interventions are necessary, which leads to an elevated risk for patients and an increase of health care costs. The aim of our study is to investigate the feasibility of powering an endocardial pacemaker by converting a minimal amount of the heart's kinetic energy into electric energy. The intrinsic cardiac muscle activity makes it an ideal candidate as continuous source of energy for endocardial pacemakers. For this reason, we developed a prototype able to generate enough power to supply a pacing circuit at different heart rates. The prototype consists of a mass imbalance that drives an electromagnetic generator while oscillating. We developed a mathematical model to estimate the amount of energy harvested from the right ventricle. Finally, the implemented prototype was successfully tested during in-vitro and in-vivo experiments

    Feasibility of transesophageal phrenic nerve stimulation.

    Get PDF
    BACKGROUND Every year, more than 2.5 million critically ill patients in the ICU are dependent on mechanical ventilation. The positive pressure in the lungs generated by the ventilator keeps the diaphragm passive, which can lead to a loss of myofibers within a short time. To prevent ventilator-induced diaphragmatic dysfunction (VIDD), phrenic nerve stimulation may be used. OBJECTIVE The goal of this study is to show the feasibility of transesophageal phrenic nerve stimulation (TEPNS). We hypothesize that selective phrenic nerve stimulation can efficiently activate the diaphragm with reduced co-stimulations. METHODS An in vitro study in saline solution combined with anatomical findings was performed to investigate relevant stimulation parameters such as inter-electrode spacing, range to target site, or omnidirectional vs. sectioned electrodes. Subsequently, dedicated esophageal electrodes were inserted into a pig and single stimulation pulses were delivered simultaneously with mechanical ventilation. Various stimulation sites and response parameters such as transdiaphragmatic pressure or airway flow were analyzed to establish an appropriate stimulation setting. RESULTS Phrenic nerve stimulation with esophageal electrodes has been demonstrated. With a current amplitude of 40 mA, similar response figures of the diaphragm activation as compared to conventional stimulation with needle electrodes at 10mA were observed. Directed electrodes best aligned with the phrenic nerve resulted in up to 16.9 % higher amplitude at the target site in vitro and up to 6 cmH20 higher transdiaphragmatic pressure in vivo as compared to omnidirectional electrodes. The activation efficiency was more sensitive to the stimulation level inside the esophagus than to the inter-electrode spacing. Most effective and selective stimulation was achieved at the level of rib 1 using sectioned electrodes 40 mm apart. CONCLUSION Directed transesophageal phrenic nerve stimulation with single stimuli enabled diaphragm activation. In the future, this method might keep the diaphragm active during, and even support, artificial ventilation. Meanwhile, dedicated sectioned electrodes could be integrated into gastric feeding tubes

    Modulation Scheme Analysis for Low-Power Leadless Pacemaker Synchronization Based on Conductive Intracardiac Communication

    Get PDF
    Conductive intracardiac communication (CIC) has been demonstrated as a promising concept for the synchronization of multi-chamber leadless cardiac pacemakers (LLPMs). To meet the 2–5 μ W power budget of a LLPM, highly specialized CIC-transceivers, which make optimal use of the cardiac communication channel, need to be developed. However, a detailed investigation of the optimal communication parameters for CIC-based LLPM synchronization is missing so far. This work analyzes the intracardiac communication performance of two low-power modulation techniques, namely On-Off-Keying (OOK) and Manchester-encoded baseband transmission (BB-MAN), as a function of the transmitted bit-energy. The bit error rate (BER) of a prototype dual-chamber LLPM was determined both in simulation and in-vitro experiments on porcine hearts. A BER of 1e − 4 was achieved with a median bit-energy in the range of 3-16 pJ (interquartile range: 4-15 pJ) for data rates from 75-500 kbps and a receiver input noise density of 7 nV/ √Hz . Both modulation schemes showed comparable performance, with BB-MAN having a slight bit-energy advantage (1-2 dB at 150-500 kbps) under equalized transceiver characteristics. This study demonstrates that reliable CIC-based LLPM synchronization is feasible at transmitted power levels < 10 nW under realistic channel conditions and receiver noise performance. Therefore, modulation techniques such, as BB-MAN or OOK, are preferable over recently proposed alternatives, such as pulse position modulation or conductive impulse signaling, since they can be realized with fewer hardware resources and smaller bandwidth requirements. Ultimately, a baseband communication approach might be favored over OOK, due to the more efficient cardiac signal transmission and reduced transceiver complexity

    Improved detection of Rhodococcus coprophilus with a new quantitative PCR assay

    Get PDF
    Agricultural practices, such as spreading liquid manure or the utilisation of land as animal pastures, can result in faecal contamination of water resources. Rhodococcus coprophilus is used in microbial source tracking to indicate animal faecal contamination in water. Methods previously described for detecting of R. coprophilus in water were neither sensitive nor specific. Therefore, the aim of this study was to design and validate a new quantitative polymerase chain reaction (qPCR) to improve the detection of R. coprophilus in water. The new PCR assay was based on the R. coprophilus 16S rRNA gene. The validation showed that the new approach was specific and sensitive for deoxyribunucleic acid from target host species. Compared with other PCR assays tested in this study, the detection limit of the new qPCR was between 1 and 3 log lower. The method, including a filtration step, was further validated and successfully used in a field investigation in Switzerland. Our work demonstrated that the new detection method is sensitive and robust to detect R. coprophilus in surface and spring water. Compared with PCR assays that are available in the literature or to the culture-dependent method, the new molecular approach improves the detection of R. coprophilu
    • …