39 research outputs found

    A case of unexplained dyspnoea: When lung function testing matters!

    Get PDF
    Diverse methods are available for assessment of the respiratory muscles; the technique used should be tailored to the question posed. http://ow.ly/ChbX30m91bt

    Physiological Validation of an Airborne Ultrasound Based Surface Motion Camera for a Contactless Characterization of Breathing Pattern in Humans

    Get PDF
    Characterizing the breathing pattern in naturally breathing humans brings important information on respiratory mechanics, respiratory muscle, and breathing control. However, measuring breathing modifies breathing (observer effect) through the effects of instrumentation and awareness: measuring human breathing under true ecological conditions is currently impossible. This study tested the hypothesis that non-contact vibrometry using airborne ultrasound (SONAR) could measure breathing movements in a contactless and invisible manner. Thus, first, we evaluated the validity of SONAR measurements by testing their interchangeability with pneumotachograph (PNT) measurements obtained at the same time. We also aimed at evaluating the observer effect by comparing breathing variability obtained by SONAR versus SONAR-PNT measurements. Twenty-three healthy subjects (12 men and 11 women; mean age 33 years – range: 20–54) were studied during resting breathing while sitting on a chair. Breathing activity was described in terms of ventilatory flow measured using a PNT and, either simultaneously or sequentially, with a SONAR device measuring the velocity of the surface motion of the chest wall. SONAR was focused either anteriorly on the xiphoid process or posteriorly on the lower part of the costal margin. Discrete ventilatory temporal and volume variables and their coefficients of variability were calculated from the flow signal (PNT) and the velocity signal (SONAR) and tested for interchangeability (Passing-Bablok regression). Tidal volume (VT) and displacement were linearly related. Breathing frequency (BF), total cycle time (TT), inspiratory time (TI), and expiratory time (TE) met interchangeability criteria. Their coefficients of variation were not statistically significantly different with PNT and SONAR-only. This was true for both the anterior and the posterior SONAR measurements. Non-contact vibrometry using airborne ultrasound is a valid tool for measuring resting breathing pattern

    Les ateliers pluridisciplinaires de développement des habiletés motrices

    Get PDF
    Contains fulltext : 157607.pdf (publisher's version ) (Open Access)403 p

    The Relationship Between Respiratory-Related Premotor Potentials and Small Perturbations in Ventilation

    No full text
    International audienceRespiratory-related premotor potentials from averaged electroencephalography (EEG) over the motor areas indicate cortical activation in healthy participants to maintain ventilation in the face of moderate inspiratory or expiratory loads. These experimental conditions are associated with respiratory discomfort, i.e., dyspnea. Premotor potentials are also observed in resting breathing in patients with reduced automatic respiratory drive or respiratory muscle strength due to respiratory or neurological disease, presumably in an attempt to maintain ventilation. The aim of this study was to determine if small voluntary increases in ventilation or smaller load-capacity imbalances, that generate an awareness of breathing but aren't necessarily dyspneic, give rise to respiratory premotor potentials in healthy participants. In 15 healthy subjects, EEG was recorded during voluntary large breaths (∌3× tidal volume, that were interspersed with smaller non-voluntary breaths in the same trial; in 10 subjects) and breathing with a 'low' inspiratory threshold load (∌7 cmH2O; in 8 subjects). Averaged EEG signals at Cz and FCz were assessed for premotor potentials prior to inspiration. Premotor potential incidence in large breaths was 40%, similar to that in the smaller non-voluntary breaths in the same trial (20%; p > 0.05) and to that in a separate trial of resting breathing (0%; p > 0.05). The incidence of premotor potentials was 25% in the low load condition, similar to that in resting breathing (0%; p > 0.05). In contrast, voluntary sniffs were always associated with a higher incidence of premotor potentials (100%; p < 0.05). We have demonstrated that in contrast to respiratory and neurological disease, there is no significant cortical contribution to increase tidal volume or to maintain the load-capacity balance with a small inspiratory threshold load in healthy participants as detected using event-related potential methodology. A lack of cortical contribution during loading was associated with low ratings of respiratory discomfort and minimal changes in ventilation. These findings advance our understanding of the neural control of breathing in health and disease and how respiratory-related EEG may be used for medical technologies such as brain-computer interfaces

    The supplementary motor area exerts a tonic excitatory influence on corticospinal projections to phrenic motoneurons in awake humans.

    Get PDF
    INTRODUCTION: In humans, cortical mechanisms can interfere with autonomic breathing. Respiratory-related activation of the supplementary motor area (SMA) has been documented during voluntary breathing and in response to inspiratory constraints. The SMA could therefore participate in the increased resting state of the respiratory motor system during wake (i.e. "wakefulness drive to breathe"). METHODS: The SMA was conditioned by continuous theta burst magnetic stimulation (cTBS, inhibitory) and 5 Hz conventional rTMS (5 Hz, excitatory). The ensuing effects were described in terms of the diaphragm motor evoked response (DiMEPs) to single-pulse transcranial magnetic stimulation over the motor cortex. DiMEPs were recorded at baseline, and at 3 time-points ("post1", "post2", "post3") up to 15 minutes following conditioning of the SMA. RESULTS: cTBS reduced the amplitude of DiMEPs from 327.5 ± 159.8 ”V at baseline to 243.3 ± 118.7 ”V, 217.8 ± 102.9 ”V and 240.6 ± 123.9 ”V at post 1, post 2 and post 3, respectively (F = 6.341, p = 0.002). 5 Hz conditioning increased the amplitude of DiMEPs from 184.7 ± 96.5 ”V at baseline to 270.7 ± 135.4 ”V at post 3 (F = 4.844, p = 0.009). CONCLUSIONS: The corticospinal pathway to the diaphragm can be modulated in both directions by conditioning the SMA. This suggests that the baseline respiratory activity of the SMA represents an equipoise from which it is possible to move in either direction. The resting corticofugal outflow from the SMA to phrenic motoneurones that this study evidences could putatively contribute to the wakefulness drive to breathe

    Medical hypnosis mitigates laboratory dyspnoea in healthy humans: a randomised, controlled experimental trial

    No full text
    International audienceQuestion Dyspnoea persisting despite treatments of underlying causes requires symptomatic approaches. Medical hypnosis could provide relief without the untoward effects of pharmacological approaches. We addressed this question through experimentally induced dyspnoea in healthy humans (inspiratory threshold loading –excessive inspiratory effort– and carbon dioxide stimulation –air hunger–) Material and Methods 20 volunteers (10 women, 21–40) were studied on 4 separate days. The order of the visits was randomised in two steps, firstly “inspiratory threshold loading first” versus “carbon dioxide first” group (n=10 in each group), secondly “medical hypnosis first” versus “visual distraction first” subgroup (n=5 in each subgroup). Each visit comprised three 5-minutes periods (reference, intervention, washout) during which participants used visual analog scales to rate dyspnoea's sensory and affective dimensions and after which they completed the Multidimensional Dyspnea Profile. Results Medical hypnosis reduced both dimensions of dyspnoea significantly more than visual distraction (inspiratory threshold loading: sensory reduction after 5 min 34% of full VAS versus 8% –p=0.0042–; affective reduction 17.6% versus 2.4% –p=0.044–; carbon dioxide; sensory reduction after 5 min 36.9% versus 3% –p=0.0015–; affective reduction 29.1% versus 8.7% –p=0.0023–). The Multidimensional Dyspnea Profile showed more marked sensory effects during inspiratory threshold loading and more marked affective effects during carbon dioxide stimulation. Answer to the question Medical hypnosis was more effective than visual distraction at attenuating the sensory and affective dimensions of experimentally induced dyspnoea. This provides a strong rationale for clinical studies of hypnosis in persistent dyspnoea patients

    The Relationship Between Respiratory-Related Premotor Potentials and Small Perturbations in Ventilation

    No full text
    Respiratory-related premotor potentials from averaged electroencephalography (EEG) over the motor areas indicate cortical activation in healthy participants to maintain ventilation in the face of moderate inspiratory or expiratory loads. These experimental conditions are associated with respiratory discomfort, i.e., dyspnea. Premotor potentials are also observed in resting breathing in patients with reduced automatic respiratory drive or respiratory muscle strength due to respiratory or neurological disease, presumably in an attempt to maintain ventilation. The aim of this study was to determine if small voluntary increases in ventilation or smaller load-capacity imbalances, that generate an awareness of breathing but aren’t necessarily dyspneic, give rise to respiratory premotor potentials in healthy participants. In 15 healthy subjects, EEG was recorded during voluntary large breaths (∌3× tidal volume, that were interspersed with smaller non-voluntary breaths in the same trial; in 10 subjects) and breathing with a ‘low’ inspiratory threshold load (∌7 cmH2O; in 8 subjects). Averaged EEG signals at Cz and FCz were assessed for premotor potentials prior to inspiration. Premotor potential incidence in large breaths was 40%, similar to that in the smaller non-voluntary breaths in the same trial (20%; p &gt; 0.05) and to that in a separate trial of resting breathing (0%; p &gt; 0.05). The incidence of premotor potentials was 25% in the low load condition, similar to that in resting breathing (0%; p &gt; 0.05). In contrast, voluntary sniffs were always associated with a higher incidence of premotor potentials (100%; p &lt; 0.05). We have demonstrated that in contrast to respiratory and neurological disease, there is no significant cortical contribution to increase tidal volume or to maintain the load-capacity balance with a small inspiratory threshold load in healthy participants as detected using event-related potential methodology. A lack of cortical contribution during loading was associated with low ratings of respiratory discomfort and minimal changes in ventilation. These findings advance our understanding of the neural control of breathing in health and disease and how respiratory-related EEG may be used for medical technologies such as brain-computer interfaces
    corecore