21 research outputs found

    Two-dimensional finite element simulation of fracture and fatigue behaviours of alumina microstructures for hip prosthesis

    Get PDF
    This paper describes a two-dimensional (2D) finite element simulation for fracture and fatigue behaviours of pure alumina microstructures such as those found at hip prostheses. Finite element models are developed using actual Al2O3 microstructures and a bilinear cohesive zone law. Simulation conditions are similar to those found at a slip zone in a dry contact between a femoral head and an acetabular cup of hip prosthesis. Contact stresses are imposed to generate cracks in the models. Magnitudes of imposed stresses are higher than those found at the microscopic scale. Effects of microstructures and contact stresses are investigated in terms of crack formation. In addition, fatigue behaviour of the microstructure is determined by performing simulations under cyclic loading conditions. It is shown that crack density observed in a microstructure increases with increasing magnitude of applied contact stress. Moreover, crack density increases linearly with respect to the number of fatigue cycles within a given contact stress range. Meanwhile, as applied contact stress increases, number of cycles to failure decreases gradually. Finally, this proposed finite element simulation offers an effective method for identifying fracture and fatigue behaviours of a microstructure provided that microstructure images are available

    Ceramics for Prosthetic Hip and Knee Joint Replacement

    No full text
    The most commonly used bearing couple in prosthetic hip or knee joint replacements consists of a cobalt-chrome (CoCr) metal alloy articulating against ultrahigh-molecular-weight polyethylene. Ceramics have been used as an alternative to metal-on-polyethylene in joint replacement surgery of arthritic hips and knees since the 1970s. In prosthetic hip and knee bearings, ceramic surfaces offer a major benefit of drastically reduced wear rates and excellent long-term biocompatibility, which can increase the longevity of prosthetic hip and knee joints. This benefit is important clinically because hip and knee replacement has become a very common surgical procedure, particularly in the United States, and because these procedures are being increasingly performed in younger patients who place greater demands on the prosthetic bearings. However, ceramics are brittle and the risk of catastrophic bearing failure in vivo, while rare, is a major concern. Improvements in material quality, manufacturing methods, and implant design have resulted in a drastic reduction of the incidence of such failures, so that modern ceramic bearings are safe and reliable if used with components of proven design and durability. Future material improvements are actively being investigated to reduce the risk of ceramic-bearing failures even further. The purpose of this article is to review the structure, properties, applications, and limitations of the ceramics that have been used in orthopedic bearings, and to describe the new ceramic composite materials and surface treatments that will be available for joint replacement surgery in the near future

    Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty

    No full text
    Alumina-on-alumina bearings in total hip arthroplasty have been developed in an attempt to minimise debris and the occurrence of osteolytic lesions. The outstanding tribological properties of this bearing system are explained by low surface roughness, high hardness for major scratch resistance, and high wettability. Since the 1970s, technological improvements in the manufacturing process of alumina components together with a better understanding of Morse taper technology have provided a surgical grade material with high density, high purity and small grains. Published studies on the outcome of total hip arthroplasty performed with this new generation of implants showed high survivorship especially in young and active patients, with survival rates free of revision of 90.8% to 97.4% at ten years. However, concern remains over ceramic liner fracture and squeaking, which has been noted recently with increasing prevalence. This review will discuss the current knowledge on the use of alumina-on-alumina bearings
    corecore