7,470 research outputs found

    Global and regional left ventricular myocardial deformation measures by magnetic resonance feature tracking in healthy volunteers: comparison with tagging and relevance of gender

    Get PDF
    This work was funded by a grant from the Engineering and Physical Sciences Research Council (EP/G030693/1) and supported by the Oxford British Heart Foundation Centre of Research Excellence and the National Institute for Health Research Oxford Biomedical Research Centr

    Pick-up ions and associated wave energy transport at Comet P/Halley: A case study

    Get PDF
    During the flyby of the spacecraft Giotto at comet p/Halley Poynting vectors and Elsässer variables have been determined to study wave propagation directions. The observed wave properties are compared with the theoretically predicted RH −, LH + and LH − wave modes. Between 10:36 and 19:11 SCET on March 13, 1986 the predicted dominating energy propagation direction mostly corresponds with the observed one. Only between 12:11 and 13:44 SCET there is no agreement. In this region the excitation of waves is dominated by pick‐up ions which are not locally implanted ions in the solar wind but have been picked‐up outside the plasma regime studied, and whose free energy is not already used up

    Electronic Scattering Effects in Europium-Based Iron Pnictides

    Get PDF
    In a comprehensive study, we investigate the electronic scattering effects in EuFe2_{2}(As1x_{1-x}Px_{x})2_{2} by using Fourier-transform infrared spectroscopy. In spite of the fact that Eu2+^{2+} local moments order around TEu20T_\text{Eu} \approx 20\,K, the overall optical response is strikingly similar to the one of the well-known Ba-122 pnictides. The main difference lies within the suppression of the lower spin-density-wave gap feature. By analysing our spectra with a multi-component model, we find that the high-energy feature around 0.7\,eV -- often associated with Hund's rule coupling -- is highly sensitive to the spin-density-wave ordering, this further confirms its direct relationship to the dynamics of itinerant carriers. The same model is also used to investigate the in-plane anisotropy of magnetically detwinned EuFe2_{2}As2_{2} in the antiferromagnetically ordered state, yielding a higher Drude weight and lower scattering rate along the crystallographic aa-axis. Finally, we analyse the development of the room temperature spectra with isovalent phosphor substitution and highlight changes in the scattering rate of hole-like carriers induced by a Lifshitz transition

    Microtubules: Montroll's kink and Morse vibrations

    Full text link
    Using a version of Witten's supersymmetric quantum mechanics proposed by Caticha, we relate Montroll's kink to a traveling, asymmetric Morse double-well potential suggesting in this way a connection between kink modes and vibrational degrees of freedom along microtubulesComment: 2pp, twocolum

    A Phase III Randomized Trial of Gemcitabine–Oxaliplatin versus Carboplatin–Paclitaxel as First-Line Therapy in Patients with Advanced Non-small Cell Lung Cancer

    Get PDF
    Purpose:This phase III study compared the efficacy and tolerability of gemcitabine and oxaliplatin (GEMOX) with paclitaxel and carboplatin (PCb) in chemotherapy-naive patients with stage IIIB/IV non-small cell lung cancer.Patients and Methods:Patients aged 18 years or older were randomized to PCb (paclitaxel 225 mg/m2 followed by carboplatin area under the curve = 6 on day 1 every 3 weeks) or GEMOX (gemcitabine 1,000 mg/m2 on days 1 and 8 followed by oxaliplatin 130 mg/m2 on day 1 every 3 weeks) for up to six cycles. The primary end point was progression-free survival (PFS), with tumor response rate, overall survival (OS), and quality of life as secondary end points.Results:The study was terminated after 383 patients had been randomized (371 received treatment) as the incidence of adverse events had exceeded the protocol-specified safety threshold (≥20% in either arm). No formal statistical comparisons were conducted. Median PFS was 4.44 months and 4.67 months in the GEMOX and PCb groups, respectively. Objective response rates (complete or partial) were 15.2% and 22.4% in the GEMOX and PCb arms, respectively. Median OS was 9.90 months (GEMOX) and 9.24 months (PCb); post hoc analyses showed median OS in patients aged 70 years or older to be similar to those younger than 70 years. PFS was similar in both groups of patients with adenocarcinoma histology, although OS favored the GEMOX group. Quality of life was improved from baseline in both groups. Toxicity profiles were comparable between the groups.Conclusion:PFS, OS, and objective response rates with GEMOX were similar to PCb. Nevertheless, toxicities limit the adoption of this regimen for routine use in advanced non-small cell lung cancer

    Measurement of liver iron by magnetic resonance imaging in the UK Biobank population

    Get PDF
    The burden of liver disease continues to increase in the UK, with liver cirrhosis reported to be the third most common cause of premature death. Iron overload, a condition that impacts liver health, was traditionally associated with genetic disorders such as hereditary haemochromatosis, however, it is now increasingly associated with obesity, type-2 diabetes and non-alcoholic fatty liver disease. The aim of this study was to assess the prevalence of elevated levels of liver iron within the UK Biobank imaging study in a cohort of 9108 individuals. Magnetic resonance imaging (MRI) was undertaken at the UK Biobank imaging centre, acquiring a multi-echo spoiled gradient-echo single-breath-hold MRI sequence from the liver. All images were analysed for liver iron and fat (expressed as proton density fat fraction or PDFF) content using LiverMultiScan™. Liver iron was measured in 97.3% of the cohort. The mean liver iron content was 1.32 ± 0.32 mg/g while the median was 1.25 mg/g (min: 0.85 max: 6.44 mg/g). Overall 4.82% of the population were defined as having elevated liver iron, above commonly accepted 1.8 mg/g threshold based on biochemical iron measurements in liver specimens obtained by biopsy. Further analysis using univariate models showed elevated liver iron to be related to male sex (p5.6% PDFF) was associated with a slight increase in prevalence of elevated liver iron (4.4% vs 6.3%, p=0.0007). This study shows that population studies including measurement of liver iron concentration are feasible, which may in future be used to better inform patient stratification and treatment

    Age effect on retina and optic disc normal values

    Get PDF
    Purpose: To investigate retinal thickness and optic disc parameters by the Retinal Thickness Analyzer (RTA) glaucoma program in older normal subjects and to determine any age effect. Methods: Subjects over 40 years of age without any prior history of eye diseases were recruited. Only subjects completely normal on clinical ophthalmologic examination and on visual field testing by Humphrey Field Analyzer (HFA) using the SITA 24-2 program were included. A total of 74 eyes from 74 subjects with even age distribution over the decades were enrolled and underwent topographic measurements of the posterior pole and of the optic disc by RTA. The `glaucoma full' program in software version 4.11B was applied. Results: Mean patient age was 59.9 +/- 10.3 years with a range from 40 to 80 years. The only parameter intraocular pressure (IOP) correlated with was retinal posterior pole asymmetry (r=0.27, p=0.02). IOP itself increased significantly with age (r=0.341, p=0.003). Mean defect and pattern standard deviation of the HFA did not correlate with any of the retinal or optic disc measurements. Increasing age correlated significantly with some of the morphologic measurements of the RTA: decreasing perifoveal minimum thickness (r=-0.258, p=0.026), increased cup-to-disc area ratio (r=0.302, p=0.016) and increased cup area (r=0.338 p=0.007). Conclusions: An age effect exists for some of the retina and optic disc measurements obtained by the RTA. Copyright (C) 2005 S. Karger AG, Basel

    Persistent detwinning of iron pnictides by small magnetic fields

    Full text link
    Our comprehensive study on EuFe2_2As2_2 reveals a dramatic reduction of magnetic detwinning fields compared to other AFe2_2As2_2 (A = Ba, Sr, Ca) iron pnictides by indirect magneto-elastic coupling of the Eu2+^{2+} ions. We find that only 0.1T are sufficient for persistent detwinning below the local Eu2+^{2+} ordering; above TEuT_\text{Eu} = 19K, higher fields are necessary. Even after the field is switched off, a significant imbalance of twin domains remains constant up to the structural and electronic phase transition (190K). This persistent detwinning provides the unique possibility to study the low temperature electronic in-plane anisotropy of iron pnictides without applying any symmetrybreaking external force.Comment: accepted by Physical Review Letter

    HST/STIS Ultraviolet Imaging of Polar Aurora on Ganymede

    Get PDF
    We report new observations of the spectrum of Ganymede in the spectral range 1160 - 1720 A made with the Space Telescope Imaging Spectrograph (STIS) on HST on 1998 October 30. The observations were undertaken to locate the regions of the atomic oxygen emissions at 1304 and 1356 A, previously observed with the GHRS on HST, that Hall et al. (1998) claimed indicated the presence of polar aurorae on Ganymede. The use of the 2" wide STIS slit, slightly wider than the disk diameter of Ganymede, produced objective spectra with images of the two oxygen emissions clearly separated. The OI emissions appear in both hemispheres, at latitudes above 40 degrees, in accordance with recent Galileo magnetometer data that indicate the presence of an intrinsic magnetic field such that Jovian magnetic field lines are linked to the surface of Ganymede only at high latitudes. Both the brightness and relative north-south intensity of the emissions varied considerably over the four contiguous orbits (5.5 hours) of observation, presumably due to the changing Jovian plasma environment at Ganymede. However, the observed longitudinal non-uniformity in the emission brightness at high latitudes, particularly in the southern hemisphere, and the lack of pronounced limb brightening near the poles are difficult to understand with current models. In addition to observed solar HI Lyman-alpha reflected from the disk, extended Lyman-alpha emission resonantly scattered from a hydrogen exosphere is detected out to beyond two Ganymede radii from the limb, and its brightness is consistent with the Galileo UVS measurements of Barth et al. (1997).Comment: 7 pages, 4 figures, accepted for publication in ApJ, June 1, 200
    corecore