18 research outputs found

    Comparative return of imports into the state of Pahang during the first quarters, 1917 and 1916.

    Get PDF
    Supplement to the F.M.S Government Gazette, July 6th, 1917. It also contains 'Comparative return of exports into the state of Pahang during the first quarters, 1917 and 1916'

    Femoroacetabular impingement and its implications on range of motion: A case report

    No full text
    Introduction :Femoroacetabular impingement leads to limited hip motion, pain and progressive damage to the labrum. Assessment of the amount and location of excessive ossification can be difficult, and removal does not always lead to pain relief and an increase of function. One of the challenges ahead is to discover why certain cases have poor outcomes. Case presentation: The technical and clinical results of two consecutive arthroscopic shavings of an osseous cam protrusion are described in our patient, a 50-year-old Caucasian man with complaints of femoroacetabular impingement. At 12 weeks after the first arthroscopic shaving, our patient still experienced pain. Using a range of motion simulation system based on computed tomography images the kinematics of his hip joint were analyzed. Bone that limited range of motion was removed in a second arthroscopic procedure. At six months post-operatively our patient is almost pain free and has regained a range of motion to a functional level. Conclusion: This case demonstrates the relevance of range of motion simulation when the outcome of primary arthroscopic management is unsatisfactory. Such simulations may aid clinicians in determining the gain of a second operation. This claim is supported by the correlation of the simulations with clinical outcome, as shown in this case report.Computer GraphicsElectrical Engineering, Mathematics and Computer Scienc

    Water Jet Applicator for Interface Tissue Removal in Minimally Invasive Hip Refixation: Testing the Principle and Design of Prototype

    No full text
    Mechanical loosening of implants is in the majority accompanied with a periprosthetic interface membrane, which has to be removed during revision surgery. The same is true if a minimal invasive (percutaneous) refixation of a loose implant is done. We describe the requirements for a waterjet applicator for interface tissue removal for this percutaneous hip refixation technique. The technical requirements were either obtained from a literature review, a theoretical analysis, or by experimental setup. Based on the requirements, a waterjet applicator is designed which is basically a flexible tube (outer diameter 3 mm) with two channels. One channel for the water supply (diameter 0.9 mm) and one for suction to evacuate water and morcellated interface tissue from the periprosthetic cavity. The applicator has a rigid tip (length 6 mm), which directs the water flow to create two waterjets (diameter 0.2 mm), both focused into the suction channel. The functionality of this new applicator is demonstrated by testing a prototype of the applicator tip in an in vitro experimental setup. This testing has shown that the designed applicator for interface tissue removal will eliminate the risk of water pressure buildup; the ejected water was immediately evacuated from the periprosthetic cavity. Blocking of the suction opening was prevented because the jets cut through interface tissue that gets in front of the suction channel. Although further development of the water applicator is necessary, the presented design of the applicator is suitable for interface tissue removal in a minimally invasive hip refixation procedure.Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Medical Instruments & Bio-Inspired TechnologyBiomechatronics & Human-Machine ControlBiomaterials & Tissue Biomechanic

    Kinematics and early migration in single-radius mobile- and fixed-bearing total knee prostheses

    Get PDF
    Background The mobile-bearing variant of a single-radius design is assumed to provide more freedom of motion compared to the fixed-bearing variant because the insert does not restrict the natural movements of the femoral component. This would reduce the contact stresses and wear which in turn may have a positive effect on the fixation of the prosthesis to the bone and thereby decreases the risk for loosening. The aim of this study was to evaluate early migration of the tibial component and kinematics of a mobile-bearing and fixed-bearing total knee prosthesis of the same single-radius design. Methods Twenty Triathlon single-radius posterior-stabilized knee prostheses were implanted (9 mobile-bearing and 11 fixed-bearing). Fluoroscopy and roentgen stereophotogrammetric analysis (RSA) were performed 6 and 12 months post-operatively. Findings The 1 year post-operative RSA results showed considerable early migrations in 3 out of 9 mobile-bearing patients and 1 out of 11 fixed-bearing patients. The range of knee flexion was the same for the mobile-bearing and fixed-bearing group. The mobile insert was following the femoral component during motion. Interpretation Despite the mobile insert following the femoral component during motion, and therefore performing as intended, no kinematic advantages of the mobile-bearing total knee prosthesis were seen. The fixed-bearing knee performed as good as the mobile-bearing knee and maybe even slightly better based on less irregular kinematics and less early migrations.Biomechanical EngineeringMechanical, Maritime and Materials Engineerin

    Peri-prosthetic tissue cells show osteogenic capacity to differentiate into the osteoblastic lineage

    Get PDF
    During the process of aseptic loosening of prostheses, particulate wear debris induces a continuous inflammatory-like response resulting in the formation of a layer of fibrous peri-prosthetic tissue at the bone-prosthesis interface. The current treatment for loosening is revision surgery which is associated with a high-morbidity rate, especially in old patients. Therefore, less invasive alternatives are necessary. One approach could be to re-establish osseointegration of the prosthesis by inducing osteoblast differentiation in the peri-prosthetic tissue. Therefore, the aim of this study was to investigate the capacity of peri-prosthetic tissue cells to differentiate into the osteoblast lineage. Cells isolated from peri-prosthetic tissue samples (n = 22)−obtained during revision surgeries−were cultured under normal and several osteogenic culture conditions. Osteogenic differentiation was assessed by measurement of Alkaline Phosphatse (ALP), mineralization of the matrix and expression of several osteogenic genes. Cells cultured in osteogenic medium showed a significant increase in ALP staining (p = 0.024), mineralization of the matrix (p < 0.001) and ALP gene expression (p = 0.014) compared to normal culture medium. Addition of bone morphogenetic proteins (BMPs), a specific GSK3β inhibitor (GIN) or a combination of BMP and GIN to osteogenic medium could not increase ALP staining, mineralization, and ALP gene expression. In one donor, addition of GIN was required to induce mineralization of the matrix. Overall, we observed a high-inter-donor variability in response to osteogenic stimuli. In conclusion, peri-prosthetic tissue cells, cultured under osteogenic conditions, can produce alkaline phosphatase and mineralized matrix, and therefore show characteristics of differentiation into the osteoblastic lineage.Biomaterials & Tissue Biomechanic

    Palacos compared to Palamed bone cement in total hip replacement: a randomized controlled trial: RSA migration similar at 10-year follow-up

    Get PDF
    Background and purpose — Stability and survival of cemented total hip prostheses is dependent on a multitude of factors, including the type of cement that is used. Bone cements vary in viscosity, from low to medium and high. There have been few clinical RSA studies comparing the performance of low- and high-viscosity bone cements. We compared the migration behavior of the Stanmore hip stem cemented using novel low-viscosity Palamed bone cement with that of the same stem cemented with conventional high-viscosity Palacos bone cement. Patients and methods — We performed a randomized controlled study involving 39 patients (40 hips) undergoing primary total hip replacement for primary or secondary osteoarthritis. 22 patients (22 hips) were randomized to Palacos and 17 patients (18 hips) were randomized to Palamed. Migration was determined by RSA. Results — None of these 40 hips had been revised at the 10-year follow-up mark. To our knowledge, the patients who died before they reached the 10-year endpoint still had the implant in situ. No statistically significant or clinically significant differences were found between the 2 groups for mean translations, rotations, and maximum total-point motion (MTPM). Interpretation — We found similar migration of the Stanmore stem in the high-viscosity Palacos cement group and the low-viscosity Palamed cement group. We therefore expect that the risk of aseptic loosening with the new Palamed cement would be comparable to that with the conventional Palacos cement. The choice of which type of bone cement to use is therefore up to the surgeon’s preference.Biomaterials & Tissue Biomechanic

    Co-contraction in RA patients with a mobile bearing total knee prosthesis during a step-up task

    No full text
    It was hypothesized that rheumatoid arthritis (RA) patients with a total knee prosthesis that allows axial rotation of the bearing (MB) will show more co-contraction to stabilize the knee joint during a step-up task than RA patients with a fixed bearing total knee prosthesis (FB) where this rotational freedom is absent while having the same articular geometry. Surface EMG, kinematics and kinetics about the knee were recorded during a step-up task of a MB group (n = 5), a FB group (n = 4) and a control group (n = 8). Surface EMG levels of thigh muscles were calibrated to either knee flexion or extension moments by means of isokinetic contractions on a dynamometer. During the step-up task co-contraction indices were determined from an EMG-force model. Controls showed a higher active ROM during the step-up task than the patient group, 96 degrees versus 88 degrees (P = 0.007). In the control group higher average muscle extension, flexion and net moments during single limb support phase were observed than in the patient group. During the 20-60% interval of the single limb support, MB patients showed a significant higher level of flexor activity, resulting in a lower net joint moment, however co-contraction levels were not different. Compared to the control group arthroplasty patients showed a 40% higher level of co-contraction during this interval (P = 0.009). Control subjects used higher extension moments, resulting in a higher net joint moment. Visual analysis revealed a timing difference between the MB and FB group. The FB group seems to co-contract approximately 20% later compared to the MB group. RA patients after total knee arthroplasty show a lower net knee joint moment and a higher co-contraction than controls indicating avoidance of net joint load and an active stabilization of the knee joint. MB and FB patients showed no difference in co-contraction levels, although timing in FB is closer to controls than MB subjects. Since visual analysis revealed a timing difference between the MB and FB group, this may express compensation by coordination. Rehabilitation programs for RA patients should include besides muscle strength training, elements of muscle-coordination training.BiomechanicsMechanical, Maritime and Materials Engineerin

    Migration behaviour of 2 clinically excellent cementless stems with different design rationales: 5-year follow-up of a randomised RSA-study

    Get PDF
    Introduction: Excellent long-term survival has been reported for both the Taperloc and the Mallory-Head cementless stems. However, little is known about the migration behaviour of these stems which have different design rationales. The purpose of this randomised clinical trial was to compare the migration and clinical outcomes of these stems during 5 years of follow-up. Methods: 42 consecutive hips in 38 patients scheduled to receive cementless THA were randomised to either a Taperloc or a Mallory-Head stem. Evaluation took place preoperatively and postoperatively on the second day, at 6, 12, 26, and 52 weeks, and annually thereafter. Primary outcome was stem migration measured using roentgen stereophotogrammetric analysis (RSA) and secondary outcomes were the Harris Hip Score (HHS) and 36-Item Short-Form Health Survey (SF-36). No patients were lost to follow-up; in 1 patient the THA was removed due to deep infection 3 months postoperatively. In 6 hips migration measurements were not possible due to insufficient marker configuration. Results: Throughout the follow-up period of 5 years, 3-dimensional migration was comparable between the Taperloc and the Mallory-Head stems (p-values > 0.05). However, at the 5-year follow-up point the retroversion of the Mallory-Head stem was 0.9° more than the Taperloc stem (p = 0.04). Initial subsidence and retroversion were respectively as large as 6.8 mm and 3.6° for the Taperloc stem and 5 mm and 3.6° for the Mallory-Head stem. After the first postoperative year, both implants had stabilised. The mean increment of HHS, as well as the SF-36 scores during the 5-year follow-up, were comparable between the 2 stems. Conclusions: The excellent long-term survival of both designs was confirmed in this study showing comparable initial migration with subsequent stabilisation. However, the Taperloc design with a flat, wedged geometry showed better rotational stability.Biomaterials & Tissue Biomechanic

    Long-term migration of a cementless stem with different bioactive coatings. Data from a “prime” RSA study: lessons learned

    Get PDF
    Background and purpose — Little is known about the long-term migration pattern of cementless stems in total hip arthroplasty (THA). Furthermore, the role of bioactive coatings in fixation, and thus migration, remains uncertain. Hydroxyapatite (HA) is the most commonly used bioactive coating. However, delamination of the coating might induce loosening. Alternatively, fluorapatite (FA) has proved to be more thermostable than HA, thereby potentially increasing longevity. We assessed the long-term migration of cementless stems with different coatings using radiostereometric analysis (RSA), thereby establishing a reference for acceptable migration. Patients and methods — 61 THAs in 53 patients were randomized to receive either a HA, FA, or uncoated Mallory-Head Porous stem during the years 1992 to 1994. Primary outcome was stem migration measured using RSA and secondary outcome was the Harris Hip Score (HHS). Evaluation took place preoperatively and postoperatively on the second day, at 6, 12, 25 and 52 weeks, and annually thereafter. At the 25-year follow-up, 12 patients (17 THAs) had died and 1 patient (1 THA) was lost to follow-up. Due to the high number of missing second-day postoperative RSA radiographs, the 1-year postoperative RSA radiograph was used as baseline for the comparative analyses. Results — Mean follow-up was 17 years (SD 6.6). All stems showed initial rapid migration with median subsidence of 0.2 mm (–0.1 to 0.6) and median retroversion of 0.9° (–3.2 to 2) at 12 months, followed by stable migration reaching a plateau phase. No stem was revised, albeit 1 stem showed continuous subsidence up to 1.5 mm. Comparing the different coatings, we could not find a statistically significant difference in overall 25-year migration (p-values > 0.05). Median subsidence at 15-year follow-up was for HA –0.1 mm (–0.4 to 0.2), for FA 0 mm (–0.1 to 0.2), and for uncoated stems 0.2 mm (–0.1 to 0.5). Median internal rotation at 15-year follow-up was for HA not available, for FA 1.1° (–0.5 to 2.6), and for uncoated stems 0° (–0.5 to 0.4). HHS were also comparable (p-values > 0.05), with at 15-year follow-up for HA 85 points (41–99), for FA 76 points (61–90), and for uncoated stems 79 points (74–90). Interpretation — The long-term migration pattern of cementless stems using different bioactive coatings has not previously been described. No beneficial effect, or side effect at long-term follow-up of bioactive coatings, was found. The provided migration data can be used in future research to establish thresholds for acceptable migration patterns cementless stem designs.Biomaterials & Tissue BiomechanicsBiomechatronics & Human-Machine Contro
    corecore