32 research outputs found

    Magnetic resonance elastography of skeletal muscle deep tissue injury

    No full text
    The current state-of-the-art diagnosis method for deep tissue injury in muscle, a subcategory of pressure ulcers, is palpation. It is recognized that deep tissue injury is frequently preceded by altered biomechanical properties. A quantitative understanding of the changes in biomechanical properties preceding and during deep tissue injury development is therefore highly desired. In this paper we quantified the spatial–temporal changes in mechanical properties upon damage development and recovery in a rat model of deep tissue injury. Deep tissue injury was induced in nine rats by two hours of sustained deformation of the tibialis anterior muscle. Magnetic resonance elastography (MRE), T 2 -weighted, and T 2 -mapping measurements were performed before, directly after indentation, and at several timepoints during a 14-day follow-up. The results revealed a local hotspot of elevated shear modulus (from 3.30 ± 0.14 kPa before to 4.22 ± 0.90 kPa after) near the center of deformation at Day 0, whereas the T 2 was elevated in a larger area. During recovery there was a clear difference in the time course of the shear modulus and T 2 . Whereas T 2 showed a gradual normalization towards baseline, the shear modulus dropped below baseline from Day 3 up to Day 10 (from 3.29 ± 0.07 kPa before to 2.68 ± 0.23 kPa at Day 10, P < 0.001), followed by a normalization at Day 14. In conclusion, we found an initial increase in shear modulus directly after two hours of damage-inducing deformation, which was followed by decreased shear modulus from Day 3 up to Day 10, and subsequent normalization. The lower shear modulus originates from the moderate to severe degeneration of the muscle. MRE stiffness values were affected in a smaller area as compared with T 2 . Since T 2 elevation is related to edema, distributing along the muscle fibers proximally and distally from the injury, we suggest that MRE is more specific than T 2 for localization of the actual damaged area

    A MRI-compatible combined mechanical loading and mr elastography setup to study deformation-induced skeletal muscle damage in rats

    Get PDF
    Deformation of skeletal muscle in the proximity of bony structures may lead to deep tissue injury category of pressure ulcers. Changes in mechanical properties have been proposed as a risk factor in the development of deep tissue injury and may be useful as a diagnostic tool for early detection. MRE allows for the estimation of mechanical properties of soft tissue through analysis of shear wave data. The shear waves originate from vibrations induced by an external actuator placed on the tissue surface. In this study a combined Magnetic Resonance (MR) compatible indentation and MR Elastography (MRE) setup is presented to study mechanical properties associated with deep tissue injury in rats. The proposed setup allows for MRE investigations combined with damage-inducing large strain indentation of the Tibialis Anterior muscle in the rat hind leg inside a small animal MR scanner. An alginate cast allowed proper fixation of the animal leg with anatomical perfect fit, provided boundary condition information for FEA and provided good susceptibility matching. MR Elastography data could be recorded for the Tibialis Anterior muscle prior to, during, and after indentation. A decaying shear wave with an average amplitude of approximately 2 μm propagated in the whole muscle. MRE elastograms representing local tissue shear storage modulus Gd showed significant increased mean values due to damage-inducing indentation (from 4.2 ± 0.1 kPa before to 5.1 ± 0.6 kPa after,

    There is an individual tolerance to mechanical loading in compression induced deep tissue injury

    No full text
    Background: Deep tissue injury is a type of pressure ulcer which originates subcutaneously due to sustained mechanical loading. The relationship between mechanical compression and damage development has been extensively studied in 2D. However, recent studies have suggested that damage develops beyond the site of indentation. The objective of this study was to compare mechanical loading conditions to the associated damage in 3D. Methods: An indentation test was performed on the tibialis anterior muscle of rats (n = 39). Changes in the form of oedema and structural damage were monitored with MRI in an extensive region. The internal deformations were evaluated using MRI based 3D finite element models. Findings: Damage propagates away from the loaded region. The 3D analysis indicates that there is a subject specific tolerance to compression induced deep tissue injury. Interpretation: Individual tolerance is an important factor when considering the mechanical loading conditions which induce damage

    MRI based 3D finite element modelling to investigate deep tissue injury

    No full text
    Pressure ulcers occur due to sustained mechanical loading. Deep tissue injury is a severe type of pressure ulcer, which is believed to originate in subcutaneous tissues adjacent to bony prominences. In previous experimental-numerical studies the relationship between internal tissue state and damage development was investigated using a 2D analysis. However, recent studies suggest that a local analysis is not sufficient. In the present study we developed a method to create animal-specific 3D finite element models of an indentation test on the tibialis anterior muscle of rats based on MRI data. A detailed description on how the animal specific models are created is given. Furthermore, two indenter geometries are compared and the influence of errors in determining the indenter orientation on the resulting internal strain distribution in a defined volume of tissue was investigated. We conclude that with a spherically-shaped indenter errors in estimating the indenter orientation do not unduly influence the results of the simulation

    MRI based 3D finite element modelling to investigate deep tissue injury

    No full text
    Pressure ulcers occur due to sustained mechanical loading. Deep tissue injury is a severe type of pressure ulcer, which is believed to originate in subcutaneous tissues adjacent to bony prominences. In previous experimental-numerical studies the relationship between internal tissue state and damage development was investigated using a 2D analysis. However, recent studies suggest that a local analysis is not sufficient. In the present study we developed a method to create animal-specific 3D finite element models of an indentation test on the tibialis anterior muscle of rats based on MRI data. A detailed description on how the animal specific models are created is given. Furthermore, two indenter geometries are compared and the influence of errors in determining the indenter orientation on the resulting internal strain distribution in a defined volume of tissue was investigated. We conclude that with a spherically-shaped indenter errors in estimating the indenter orientation do not unduly influence the results of the simulation

    MRI based 3D finite element modelling to investigate deep tissue injury

    No full text
    Pressure ulcers occur due to sustained mechanical loading. Deep tissue injury is a severe type of pressure ulcer, which is believed to originate in subcutaneous tissues adjacent to bony prominences. In previous experimental-numerical studies the relationship between internal tissue state and damage development was investigated using a 2D analysis. However, recent studies suggest that a local analysis is not sufficient. In the present study we developed a method to create animal-specific 3D finite element models of an indentation test on the tibialis anterior muscle of rats based on MRI data. A detailed description on how the animal specific models are created is given. Furthermore, two indenter geometries are compared and the influence of errors in determining the indenter orientation on the resulting internal strain distribution in a defined volume of tissue was investigated. We conclude that with a spherically-shaped indenter errors in estimating the indenter orientation do not unduly influence the results of the simulation.</p

    Assessment of Myocardial Fibrosis in Mice Using a T2*-Weighted 3D Radial Magnetic Resonance Imaging Sequence

    Get PDF
    Background Myocardial fibrosis is a common hallmark of many diseases of the heart. Late gadolinium enhanced MRI is a powerful tool to image replacement fibrosis after myocardial infarction (MI). Interstitial fibrosis can be assessed indirectly from an extracellular volume fraction measurement using contrast-enhanced T1 mapping. Detection of short T2* species resulting from fibrotic tissue may provide an attractive non-contrast-enhanced alternative to directly visualize the presence of both replacement and interstitial fibrosis. Objective To goal of this paper was to explore the use of a T2*-weighted radial sequence for the visualization of fibrosis in mouse heart. Methods C57BL/6 mice were studied with MI (n = 20, replacement fibrosis), transverse aortic constriction (TAC) (n = 18, diffuse fibrosis), and as control (n = 10). 3D center-out radial T2*-weighted images with varying TE were acquired in vivo and ex vivo (TE = 21 mu s-4 ms). Ex vivo T2*-weighted signal decay with TE was analyzed using a 3-component model. Subtraction of short-and long-TE images was used to highlight fibrotic tissue with short T2*. The presence of fibrosis was validated using histology and correlated to MRI findings. Results Detailed ex vivo T2*-weighted signal analysis revealed a fast (T2*(fast)), slow (T2*(slow)) and lipid (T2*(lipid)) pool. T2*(fast) remained essentially constant. Infarct T2*(slow) decreased significantly, while a moderate decrease was observed in remote tissue in post-MI hearts and in TAC hearts. T2*(slow) correlated with the presence of diffuse fibrosis in TAC hearts (r = 0.82, P = 0.01). Ex vivo and in vivo subtraction images depicted a positive contrast in the infarct co-localizing with the scar. Infarct volumes from histology and subtraction images linearly correlated (r = 0.94,
    corecore