518 research outputs found
Recommended from our members
Indoor acids and bases.
Numerous acids and bases influence indoor air quality. The most abundant of these species are CO2 (acidic) and NH3 (basic), both emitted by building occupants. Other prominent inorganic acids are HNO3 , HONO, SO2 , H2 SO4 , HCl, and HOCl. Prominent organic acids include formic, acetic, and lactic; nicotine is a noteworthy organic base. Sources of N-, S-, and Cl-containing acids can include ventilation from outdoors, indoor combustion, consumer product use, and chemical reactions. Organic acids are commonly more abundant indoors than outdoors, with indoor sources including occupants, wood, and cooking. Beyond NH3 and nicotine, other noteworthy bases include inorganic and organic amines. Acids and bases partition indoors among the gas-phase, airborne particles, bulk water, and surfaces; relevant thermodynamic parameters governing the partitioning are the acid-dissociation constant (Ka ), Henry's law constant (KH ), and the octanol-air partition coefficient (Koa ). Condensed-phase water strongly influences the fate of indoor acids and bases and is also a medium for chemical interactions. Indoor surfaces can be large reservoirs of acids and bases. This extensive review of the state of knowledge establishes a foundation for future inquiry to better understand how acids and bases influence the suitability of indoor environments for occupants, cultural artifacts, and sensitive equipment
Growth of organic films on indoor surfaces
We present a model for the growth of organic films on impermeable indoor surfaces. The model couples transport through a gas-side boundary layer adjacent to the surface with equilibrium partitioning of semivolatile organic compounds (SVOCs) between the gas phase and the surface film. Model predictions indicate that film growth would primarily be influenced by the gas-phase concentration of SVOCs with octanol-air partitioning (Koa ) values in the approximate range 10≤log Koa ≤13. Within the relevant range, SVOCs with lower values will equilibrate with the surface film more rapidly. Over time, the film becomes relatively enriched in species with higher log Koa values, while the proportion of gas-phase SVOCs not in equilibrium with the film decreases. Given stable airborne SVOC concentrations, films grow at faster rates initially and then subsequently diminish to an almost steady growth rate. Once an SVOC is equilibrated with the film, its mass per unit film volume remains constant, while its mass per unit area increases in proportion to overall film thickness. The predictions of the conceptual model and its mathematical embodiment are generally consistent with results reported in the peer-reviewed literature
Mathematical modeling of chemically reactive pollutants in indoor air
A general mathematical model is presented for predicting
the concentrations of chemically reactive compounds in indoor air. The model accounts for the effects of ventilation, filtration, heterogeneous removal, direct
emission, and photolytic and thermal chemical reactions.
The model is applied to the induction of photochemically
reactive pollutants into a museum gallery, and the predicted
NO, NO_x-NO, and O_3 concentrations are compared to measured data. The model predicts substantial production
of several species due to chemical reaction, including
HNO_2, HNO_3, NO_3, and N_2O_5. Circumstances in which homogeneous chemistry may assume particular importance
are identified and include buildings with glass walls, indoor combustion sources, and direct emission of olefins
Protection of Works of Art From Atmospheric Ozone
Assesses the colorfastness of organic colorants and watercolor pigments tested in atmospheric ozone. A summary of a full report of the Environmental Quality Laboratory, California Institute of Technology, Pasadena
Recommended from our members
Wind-induced Ground-surface Pressures Around a Single-Family House
Wind induces a ground-surface pressure field around a building that can substantially affect the flow of soil gas and thereby the entry of radon and other soil-gas contaminants into the building. To quantify the effect of the wind-induced groundsurface pressure field on contaminant entry rates, the mean ground-surface pressure field was experimentally measured in a wind tunnel for several incidence angles of the wind, two atmospheric boundary layers, and two house geometries. The experimentally measured ground-surface pressure fields are compared with those predicted by a k-e turbulence model. Despite the fundamental limitations in applying a k-e model to a system with flow separation, predictions from the numerical simulations were good for the two wind incidence angles tested
Recommended from our members
Instrumentation for a radon research house
A highly automated monitoring and control system for studying radon and radon-daughter behavior in residences has been designed and built. The system has been installed in a research house, a test space contained in a two-story wood-framed building, which allows us to conduct controlled studies of (1) pollutant transport within and between rooms, (2) the dynamics of radon daughter behavior, and (3) techniques for controlling radon and radon daughters. The system's instrumentation is capable of measuring air-exchange rate, four-point radon concentration, individual radon daughter concentrations, indoor temerature and humidity, and outdoor weather parameters (temperature, humidity, modules, wind speed, and wind direction). It is also equipped with modules that control the injection of radon and tracer gas into the test space, the operation of the forced-air furnace, the mechanical ventilation system, and the mixing fans located in each room. A microcomputer controls the experiments and records the data on magnetic tape and on a printing terminal. The data on tape is transferred to a larger computer system for reduction and analysis. In this paper we describe the essential design and function of the instrumentation system, as a whole, singling out those components that measure ventilation rate, radon concentration, and radon daughter concentrations
Investigating CO2 Removal by Ca- and Mg-based Sorbents with Application to Indoor Air Treatment
Indoor carbon dioxide (CO 2 ) levels serve as an indicator of ventilation sufficiency in relation to metabolic effluents. Recent evidence suggests that elevated CO 2 exposure (with or without other bioeffluents) may cause adverse cognitive effects. In shelter-in-place (SIP) facilities, indoor CO 2 levels may become particularly elevated. This study evaluates four low-cost alkaline earth metal oxides and hydroxides as CO 2 sorbents for potential use in indoor air cleaning applications. Sorbents studied were MgO, Mg(OH) 2 , Ca(OH) 2 and commercially available soda lime. Uncarbonated sorbents characterized with nitrogen adsorption porosimetry showed BET surface areas in the 5.6–27 m 2 /g range. Microstructural analyses, including X-ray diffraction, thermogravimetric analysis and scanning electron microscopy confirmed the carbonation mechanisms and extent of sorption under environmental conditions typical of indoor spaces. Ca-based sorbents demonstrated higher extent of carbonation than Mg-based sorbents. Laboratory parameterizations, including rate constants ( k ) and carbonation yields ( y ), were applied in material balance models to assess the CO 2 removal potential of Ca-based sorbents in three types of indoor environments. Soda lime ( k = [2.2–3.6] × 10 −3 m 3 mol CO 2 −1 h −1 , y = 0.49–0.51) showed potential for effective use in SIP facilities. For example, CO 2 exposure in a modeled SIP facility could be reduced by 80% for an 8-h sheltering interval and to levels below 5000 ppm for an 8-h period with a practically sized air cleaner. Predicted effectiveness was more modest for bedrooms and classroom
Airborne Particles in Museums
Presents one in a series of research activities aimed at a better understanding of the origin and fate of air pollution within the built environment
Ozone Reductions Using Residential Building Envelopes
Ozone is an air pollutant with that can have significant health effects and a significant source of ozone in some regions of California is outdoor air. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone could lead to improved health for many California residents. Ozone is removed from indoor air by surface reactions and can also be filtered by building envelopes. The magnitude of the envelope impact depends on the specific building materials that the air flows over and the geometry of the air flow paths through the envelope that can be changes by mechanical ventilation operation. The 2008 Residential Building Standards in California include minimum requirements for mechanical ventilation by referencing ASHRAE Standard 62.2. This study examines the changes in indoor ozone depending on the mechanical ventilation system selected to meet these requirements. This study used detailed simulations of ventilation in a house to examine the impacts of different ventilation systems on indoor ozone concentrations. The simulation results showed that staying indoors reduces exposure to ozone by 80percent to 90percent, that exhaust ventilation systems lead to lower indoor ozone concentrations, that opening of windows should be avoided at times of high outdoor ozone, and that changing the time at which mechanical ventilation occurs has the ability to halve exposure to ozone. Future work should focus on the products of ozone reactions in the building envelope and the fate of these products with respect to indoor exposures
- …