15 research outputs found

    Endometrial injury in women undergoing assisted reproductive techniques

    Get PDF
    ACKNOWLEDGEMENTS We would like to express our appreciation to Dra Abha Maheshwari for her important authorial contribution to the previous version of this review. We also acknowledge the important help provided by the Cochrane Menstrual Disorders and Subfertility Group team, specially by Marian Showell, Trials Search Co-ordinator; by Helen Nagels, Managing Editor; and by Prof. Cindy Farquhar, Co-ordinating Editor. Finally, we would like to express our gratitude to the following investigators, who provided essential information for the preparation of this review: TK Aleyamma, Erin F Wolff, Lukasz Polanski, Nava Dekel, Neeta Singh, Suleyman Guven and Tracy YeungPeer reviewedPublisher PD

    First trimester fetal volume and crown-rump length: Comparison between singletons and twins conceived by in vitro fertilization

    No full text
    The aim of this study was to compare the crown-rump length (CRL) and the fetal head and trunk (HT) volume between singletons and twins conceived after in vitro fertilization. Thirty pregnant patients submitted to embryo transfer were enrolled in this research. Ten conceived twins (20 dichorionic fetuses) while other 20 conceived singletons. The gestational age was calculated by adding 14 d to the number of days between the oocyte retrieval and the scheduled ultrasound. Three-dimensional ultrasound scans were performed weekly from 73 d (10 wk and 3 d) to 101 d (14 wk and 3 d) of gestational age. HT volume was assessed by VOCAL using 15 degrees step rotation on the manual mode. The measurement of CRL was performed by using the longitudinal plane of the fetus in the multiplanar view. The CRL and HT volume weekly relative increase were evaluated to compare the growth between singletons and twins. No significant difference was identified, in any analyzed week, when comparing the mean of CRL and HT volume between singletons and twins. Additionally, no significant difference between singletons and twins was noticed when comparing the weekly relative increase, both for CRL and HT volume. However, the weekly relative increase was significantly higher for HT volume than for CRL in every week studied for both singletons and twins. The total relative increase observed between 73 and 101 d was much higher for HT volume than for CRL: 679 +/- 39% versus 138 +/- 18% in singletons and 689 +/- 58% versus 139 +/- 21% in twins (HT volume and CRL, respectively), suggesting that HT volume could more accurately determine the gestational age

    PULSATILITY INDEX CHANGE OF BRACHIAL ARTERY SHOWS BETTER REPRODUCIBILITY THAN FLOW-MEDIATED VASODILATION

    No full text
    We aim to evaluate intra- and interobserver reproducibility of brachial artery flow-mediated dilation (FMD) and of pulsatility index change (PI-C) 1 min after a 5-min forearm compression in pregnant women. Flow-mediated dilation and PI-C were assessed in 31 healthy pregnant women in 3 consecutive days, by two observers. A broader range of response to the stimulus was observed for PI-C (-58.99%-86.71%) than FMD (2.38%-27.01%). The intraclass correlation coefficients were higher for PI-C than for FMD (intra = 0.90 vs. 0.69, p = 0.047; inter = 0.94 vs. 0.61, p = 0.007). Therefore, PI-C measurements were more reliable than FMD. However, studies comprising of subjects with cardiovascular risk factors relating FMD and PI-C become necessary to validate this method for the study of endothelial dysfunction. (E-mail: [email protected]) (C) 2010 World Federation for Ultrasound in Medicine & Biology

    Importance of Pulse Repetition Frequency Adjustment for 3- and 4-Dimensional Power Doppler Quantification

    No full text
    To determine the influence of the pulse repetition frequency (PRF) and wall motion filter on the 3-dimensional (3D) power Doppler vascularization-flow index (VFI) and volumetric pulsatility index (PI) obtained from spatiotemporal image correlation (STIC) data sets acquired from a common carotid artery of a healthy participant.status: publishe

    Fetal volume and crown-rump length from 7 to 10 weeks of gestational age in singletons and twins

    No full text
    Objective(s): We intend to verify if fetal volume and crown-rump length were different between singletons and twins in pregnancies aged from 7 to 10 weeks and to evaluate if fetal volume is more accurate to determine the gestational age than crown-rump length at this gestational age. Study design: From 52 days (7 weeks and 3 days) to 73 days (10 weeks and 3 days) weekly three-dimensional Ultrasonography was per-formed in 20 twin fetuses and 20 singletons. Crown-rump length and fetal volume using VOCAL were assessed in all examinations. The `true` gestational age was based on oocyte retrieval. Results: At the age of 52 days, the crown-rump length was 11.74 +/- 0.27 mm (mean +/- S.D.) and 11.48 +/- 0.22 mm (singletons and twins, respectively), while the fetal volume was 0.354 +/- 0.015 cm(3) and 0.324 +/- 0.012 cm(3). At the gestational age of 73 days, the crown-rump length was 36.19 +/- 0.90 mm and 35.87 +/- 0.54 mm and the fetal volume was 6.204 +/- 0.090 cm(3) and 6.083 +/- 0.081 cm(3). The total relative increase observed was much higher for fetal volume than for CRL: 1705 +/- 301% vs. 210 +/- 33% in singletons and 1827 +/- 305% vs. 214 +/- 25% in twins. The 95% limits of agreement (+/- 2.3 days vs. +/- 3.2 days, fetal volume vs. crown-rump length) and the intraclass correlation coefficients (0.989 vs. 0.978) between the ""true"" gestational age and that predicted by fetal volume were better than those predicted by crown-rump length. No significant difference was identified between singletons and twins for both fetal volume and crown-rump length. Conclusion(s): Twins and singletons had similar fetal volume and crown-rump length between the 7th and 10th week of gestational age. Additionally, fetal volume assessed by VOCAL was better than crown-rump length to estimate the gestational age at the evaluated period. However, the improvement was small and probably without clinical significance. Condensation: Fetal volume and crown-rump length were similar between singletons and twins. Fetal volume relative increase was higher and the predicted gestational age was better. (c) 2009 Elsevier Ireland Ltd. All rights reserved

    Evaluation of ductus venosus and inferior vena cava by using multiple Doppler ultrasound parameters in healthy fetuses

    No full text
    The objective of this study was to describe multiple Doppler ultrasound parameters of ductus venosus and inferior vena cava in fetuses at gestational ages ranging from 22 to 38 weeks. In this prospective observational study, Doppler ultrasound exams were performed in 45 healthy fetuses at 22, 26, 34, and 38 weeks. Maximum venous velocity, minimum venous velocity, venous pulsatility index, and venous acceleration time (VAT) (defined as the time between minimum and maximum venous velocity) were evaluated at those gestational periods. Increase in the velocities and decrease in the pulsatility index were observed in these vessels throughout gestational age. The VAT increased with gestational age. The VAT, a Doppler parameter still not described elsewhere, increased during pregnancy could be related to a longer period of time needed to fill the atrium in bigger hearts. In this study, we provide reference values for VAT in healthy fetuses
    corecore