11 research outputs found

    Early stage signet ring cell carcinoma of the colon examined by magnifying endoscopy with narrow-band imaging: a case report

    Get PDF
    Background: Signet ring cell carcinoma of the colon and rectum is rare, and most cases are detected at an advanced stage. We present a case of primary signet ring cell carcinoma detected at an early stage by magnifying endoscopy with narrow-band imaging (NBI) and crystal violet staining. Case presentation: A 73-year-old man visited our hospital for screening colonoscopy. Six years previously, he had undergone endoscopic submucosal dissection (ESD) for early gastric cancer. The pathological diagnosis was a well-differentiated adenocarcinoma, invading into the mucosa without lymphovascular invasion. Colonoscopy revealed a flat elevated lesion with a slightly depressed area, 20 mm in diameter, in the cecum. Further, magnifying endoscopy with NBI revealed that the surface pattern was slightly irregular and microvessels had a regular diameter and distribution in the margin of the lesion, but in the central part of the lesion, irregularity in the tumor surface pattern and form as well as in the diameter and distribution of microvessels was noted. Additionally, due to mucus, avascular areas were also observed. Magnifying endoscopy combined with 0.05 % crystal violet staining showed IIIL and VI pit patterns in the margin of the lesion, and a VI pit pattern in the central part of the lesion; however, due to mucus exudate, this finding could not be established with certainty. The lesion was successfully removed en bloc using ESD without complications. The tumor was composed mainly of signet ring cell carcinoma, partially mixed with moderately differentiated (tub2) and well-differentiated (tub1) adenocarcinomas. The tumor cells infiltrated 250 μm into the submucosal layer and involved lymphatic vessels. Therefore, the patient underwent an additional laparoscopic ileocecal resection, and the resected specimen revealed no residual carcinoma or lymph node metastasis. Conclusion: In this case report, we present a case of primary signet ring cell carcinoma detected at an early stage and identified by magnifying endoscopy with NBI and crystal violet staining

    A Python extension to the ATLAS online software for the thin gap chamber trigger system

    No full text
    A Python extension module for A Toroidal LHC Apparatus (ATLAS) Online Software has been developed for the Thin Gap Chamber (TGC) trigger system. Python is an interactive scripting language including built- in high-level libraries, and provides an easy way to build Web applications. These features are not included in the Online Software, and are important in developing test software for the TGC trigger system. The Python extension module is designed and implemented using a C++ library, "Boost.Python." We have developed a Web application using the extension module and Zope (a Python-based Web application server), which allows one to monitor the TGC trigger system from anywhere in the world. The functionalities of the Python extension module and its application for the TGC trigger system are presented. 7 Refs

    International Linear Collider Reference Design Report Volume 2: PHYSICS AT THE ILC

    No full text
    This article reviews the physics case for the ILC. Baseline running at 500 GeV as well as possible upgrades and options are discussed. The opportunities on Standard Model physics, Higgs physics, Supersymmetry and alternative theories beyond the Standard Model are described.This article reviews the physics case for the ILC. Baseline running at 500 GeV as well as possible upgrades and options are discussed. The opportunities on Standard Model physics, Higgs physics, Supersymmetry and alternative theories beyond the Standard Model are described

    ILC Reference Design Report Volume 1 - Executive Summary

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics

    ILC Reference Design Report Volume 3 - Accelerator

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC
    corecore