3,240 research outputs found

    A new view of the spin echo diffusive diffraction on porous structures

    Full text link
    Analysis with the characteristic functional of stochastic motion is used for the gradient spin echo measurement of restricted motion to clarify details of the diffraction-like effect in a porous structure. It gives the diffusive diffraction as an interference of spin phase shifts due to the back-flow of spins bouncing at the boundaries, when mean displacement of scattered spins is equal to the spin phase grating prepared by applied magnetic field gradients. The diffraction patterns convey information about morphology of the surrounding media at times long enough that opposite boundaries are restricting displacements. The method explains the dependence of diffraction on the time and width of gradient pulses, as observed at the experiments and the simulations. It also enlightens the analysis of transport properties by the spin echo, particularly in systems, where the motion is restricted by structure or configuration

    Imperfect spoiling in variable flip angle T1 mapping at 7T: Quantifying and minimizing impact

    Get PDF
    PURPOSE: The variable flip angle (VFA) approach to T1 mapping assumes perfectly spoiled transverse magnetisation at the end of each repetition time (TR). Despite radiofrequency (RF) and gradient spoiling, this condition is rarely met, leading to erroneous T1 estimates ( T 1 app ). Theoretical corrections can be applied but make assumptions about tissue properties, for example, a global T2 time. Here, we investigate the effect of imperfect spoiling at 7T and the interaction between the RF and gradient spoiling conditions, additionally accounting for diffusion. We provide guidance on the optimal approach to maximise the accuracy of the T1 estimate in the context of 3D multi-echo acquisitions. METHODS: The impact of the spoiling regime was investigated through numerical simulations, phantom and in vivo experiments. RESULTS: The predicted dependence of T 1 app on tissue properties, system settings, and spoiling conditions was observed in both phantom and in vivo experiments. Diffusion effects modulated the dependence of T 1 app on both B 1 + efficiency and T2 times. CONCLUSION: Error in T 1 app can be minimized by using an RF spoiling increment and gradient spoiler moment combination that minimizes T2 -dependence and safeguards image quality. Although the diffusion effect was comparatively small at 7T, correction factors accounting for this effect are recommended

    Partial cloning and estimation of the Culex pipiens (SELAX strain) B2 amplicon

    Get PDF
    The mechanism of resistance towards organophosphate insecticides in Culex complex mosquitoes has been shown to be associated with amplification of the structural esterase gene. The cloned portion of the SELAX strain A2-B2 amplicon was compared to that of the B1 amplicon which had been partially characterized. Fragments of known sizes from clones were used as probes to estimate the length of the B2 amplicon in the SELAX strain of mosquitoes. The two types of clones that were isolated and designated as N4 and N6, differed from each other by their size of inserts. Both clones hybridized with the 1.8 kb A2 probe and the 1.3 kb B1 probe; revealing that both N4 and N6 clones contained A2 and B2 esterase genes. Restriction enzyme digests of the clones suggested that the cloned portion of the B2 amplicon was 16 kb

    STFC Centre for Environmental Data Archival (CEDA) Annual Report 2013 (April 2012-March 2013)

    Get PDF
    The mission of the Centre for Environmental Archival (CEDA) is to deliver long term curation of scientifically important environmental data at the same time as facilitating the use of data by the environmental science community. CEDA was established by the amalgamation of the activities of two of the Natural Environment Research Council (NERC) designated data centres: the British Atmospheric Data Centre, and the NERC Earth Observation Data Centre. We are pleased to present here our fourth annual report, covering activities for the 2013 year (April 2012 to March 2013). The report consists of two sections and appendices, the first section broadly providing a summary of activities and some statistics with some short descriptions of some significant activities, and a second section introducing some exemplar projects and activities. The report concludes with additional details of activities such as publications, software maintained etc

    Investigation into use of double-layer grid structures as frequency selective surfaces for buildings

    Get PDF
    A simple Double–Layer Grid plane wave filter structure is proposed that can provide multiple transmission bands for cellular phone frequencies but with a reflection band for WLAN signals. The approach offers ease of construction making it applicable to building applications. A parametric study using simulation supported by simple experimental data investigates the proposed, novel desig

    Prospective motion correction of 3D echo-planar imaging data for functional MRI using optical tracking.

    Get PDF
    We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies

    The relationship between hippocampal-dependent task performance and hippocampal grey matter myelination and iron content

    Get PDF
    Individual differences in scene imagination, autobiographical memory recall, future thinking and spatial navigation have long been linked with hippocampal structure in healthy people, although evidence for such relationships is, in fact, mixed. Extant studies have predominantly concentrated on hippocampal volume. However, it is now possible to use quantitative neuroimaging techniques to model different properties of tissue microstructure in vivo such as myelination and iron. Previous work has linked such measures with cognitive task performance, particularly in older adults. Here we investigated whether performance on scene imagination, autobiographical memory, future thinking and spatial navigation tasks was associated with hippocampal grey matter myelination or iron content in young, healthy adult participants. Magnetic resonance imaging data were collected using a multi-parameter mapping protocol (0.8 mm isotropic voxels) from a large sample of 217 people with widely-varying cognitive task scores. We found little evidence that hippocampal grey matter myelination or iron content were related to task performance. This was the case using different analysis methods (voxel-based quantification, partial correlations), when whole brain, hippocampal regions of interest, and posterior:anterior hippocampal ratios were examined, and across different participant sub-groups (divided by gender and task performance). Variations in hippocampal grey matter myelin and iron levels may not, therefore, help to explain individual differences in performance on hippocampal-dependent tasks, at least in young, healthy individuals
    corecore