3 research outputs found

    Electronic temperatures, densities and plasma X-ray emission of a 14.5 GHz Electron-Cyclotron Resonance Ion Source

    Full text link
    We have performed a systematic study of the Bremsstrahlung emission from the electrons in the plasma of a commercial 14.5 GHz Electron-Cyclotron Resonance Ion Source. The electronic spectral temperature and the product of ionic and electronic densities of the plasma are measured by analyzing the Bremsstrahlung spectra recorded for several rare gases (Ar, Kr, Xe) as a function of the injected power. Within our uncertainty, we find an average temperature of ? 48 keV above 100W, with a weak dependency on the injected power and gas composition. Charge state distributions of extracted ion beams have been determined as well, providing a way to disentangle the ionic density from the electronic density. Moreover X-ray emission from highly charged argon ions in the plasma has been observed with a high-resolution mosaic crystal spectrometer, demonstrating the feasibility for high-precision measurements of transition energies of highly charged ions, in particular of the magnetic dipole (M1) transition of He-like of argon ions

    Failure of a repeat course of cyclooxygenase inhibitor to close a PDA is a risk factor for developing chronic lung disease in ELBW infants

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The optimal treatment regimen or protocol for managing a persistent patent ductus arteriosus (PDA) in extremely low birth weight (ELBW) infants has not been well established. This study was aimed at evaluating the failure rate of a cyclooxygenase (COX) inhibitor (COI) for PDA closure and to determine the incidence of a PDA requiring ligation in ELBW infants. We examined the clinical characteristics and risk factors that may predict the clinical consequences of failure of PDA closure by COI.</p> <p>Methods</p> <p>Medical information on 138 infants with birth weight (BW) < 1000 gm who survived for > 48 hours was retrieved. Clinical characteristics and outcomes of patients whose PDAs closed with COI were compared with those who did not close.</p> <p>Results</p> <p>Of the 138 patients, 112 survived to discharge. Eighty (71.4%) of those who survived received 1-3 courses of COI treatment for a symptomatic PDA. A total of 32 (40%) failed COI treatment and underwent PDA ligation. Multivariable logistic regression analysis suggests that the observed differences in the outcomes in infants with or without symptomatic PDA can be explained by the babies with symptomatic PDA being more immature and sicker. No significant difference was seen in the incidence of chronic lung disease (CLD) in infants whose PDA was treated medically versus those who failed medical treatment and then underwent ligation. However, after adjusting for disease severity and other known risk factors, the odds ratio of developing CLD for surviving babies with a persistent PDA compared to those whose PDA was successfully closed with 1-2 courses of COI is 3.24 (1.07-9.81; p = 0.038).</p> <p>Conclusions</p> <p>When successfully treated, PDA in ELBW infants did not contribute significantly to the adverse outcomes such as CLD, retinopathy of prematurity (ROP) and age at discharge. This suggests that it is beneficial for a hemodynamically significant PDA to be closed. The failure of a repeat course of COI to close a PDA is a major risk factor for developing CLD in ELBW infants.</p
    corecore