129 research outputs found

    The sense or nonsense of mobile-bearing total knee prostheses

    Get PDF
    The focus of this thesis was if the in vivo kinematics of total knee prostheses was consistent with the kinematics intended by design and to determine the additional value of insert mobility and thus __the sense or nonsense__ of mobile-bearing knee prostheses. The added value of this thesis to the current literature is the integration of different measurement techniques. Fluoroscopy is combined with RSA and motion analysis techniques to fully understand the in vivo knee kinematics beyond which can be obtained by either technique alone. Results demonstrate that the integration of different measurement techniques was indeed of great value to comprehend the in vivo knee kinematics.Anna Fonds Leiden, Dutch Arthritis Association, Stryker SA, J.E. Jurriaanse StichtingUBL - phd migration 201

    Systematic review and meta-analysis of measurement properties of the Hip disability and Osteoarthritis Outcome Score - Physical Function Shortform (HOOS-PS) and the Knee Injury and Osteoarthritis Outcome Score - Physical Function Shortform (KOOS-PS)

    Get PDF
    Objective: The aim of this systematic review and meta-analysis was to evaluate all evidence on measurement properties of the Hip disability and Osteoarthritis Outcome Score - Physical function Shortform (HOOS-PS) and the Knee Injury and Osteoarthritis Outcome Score - Physical function Shortform (KOOS-PS). Design: This study was conducted according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) guideline for systematic reviews of PROMs. MEDLINE, EMBASE, The Cochrane Library, CINAHL and PsychINFO through February 2019 were searched. Eligible studies evaluated patients with hip or knee complaints and described a measurement property, interpretability, feasibility, or the development of either the HOOS-PS or KOOS-PS. Results: Twenty-three studies were included. For both questionnaires, the content validity was found inconsistent and the quality evidence was moderate for a sufficient reliability and high for an insufficient construct validity. The HOOS-PS had a high quality evidence of sufficient structural validity and internal consistency (pooled Cronbach's alpha 0.80; n = 3761) and low quality evidence of sufficient measurement error and indeterminate responsiveness. Concerning the KOOS-PS, the quality evidence was high for an insufficient responsiveness, moderate for an inconsistent structural validity and internal consistency and low for an inconsistent measurement error. Conclusions: The inconsistent evidence for content validity implies that scores on the HOOS-PS and KOOS-PS may inadequately reflect physical functioning. Furthermore, there is evidence for insufficient construct validity and responsiveness in patients with knee osteoarthritis receiving conservative treatment. Using the HOOS-PS or KOOS-PS as outcome measurement instruments for comparing outcomes, measuring improvements or benchmarking in patients with hip or knee complaints or undergoing arthroplasty should only be done with great caution. Review registration: PROSPERO number CRD4201706953

    Resident training does not influence the complication risk in total knee and hip arthroplasty

    Get PDF
    Background and purpose - Gaining experience in the surgery room during residency is an important part of learning the skills needed to perform arthroplasties. However, in practice, patients are often not fully comfortable with trainee involvement in their own surgery. Therefore, we investigated complications, revision rates, mortality, and operative time of orthopedic surgeons and residents as primary surgeon performing total knee arthroplasties (TKAs) or total hip arthroplasties (THAs). Patients and methods - In this multi-center retrospective cohort study, 3,098 TKAs and 4,027 THAs performed between 2007 and 2013 were analyzed. Complications, revisions, mortality, and operative time were compared for patients operated on by the orthopedic surgeon or a resident as primary surgeon. An additional analysis was performed to determine whether the complication risk was affected by the postgraduate year of the resident. Results - Orthopedic complication rates were similar (TKA: orthopedic surgeon: 10%, resident: 11%; THA: 9% and 8%), revision rates (TKA: 3% and 2%, THA: 3% and 2%), or mortality rates (TKA: 0.1% and 0.3%, THA: 0.2% and 0.3%). For both procedures a higher non-orthopedic complication rate was found in the resident group (TKA: 8% and 10%; p = 0.03, THA: 8% and 10%; p = 0.01) and a slightly longer operative time (TKA: mean difference 9.0 minutes (8%); THA: 11.3 minutes (11%)). Interpretation - Complications, revisions, and mortality were similar in TKAs or THAs performed by the resident as primary surgeon compared with surgeries performed by an orthopedic surgeon. This data can be used in teaching hospitals and may help to reassure patients.Orthopaedics, Trauma Surgery and Rehabilitatio

    No differences in in vivo kinematics between six different types of knee prostheses

    Get PDF
    Purpose: The aim of this study was to compare a broad range of total knee prostheses with different design parameters to determine whether in vivo kinematics was consistently related to design. The hypothesis was that there are no clear recognizable differences in in vivo kinematics between different design parameters or prostheses. Methods: At two sites, data were collected by a single observer on 52 knees (49 subjects with rheumatoid arthritis or osteoarthritis). Six different total knee prostheses were used: multi-radius, single-radius, fixed-bearing, mobilebearing, posterior-stabilized, cruciate retaining and cruciate sacrificing. Knee kinematics was recorded using fluoroscopy as the patients performed a step-up motion. Results: There was a significant effect of prosthetic design on all outcome parameters; however, post hoc tests showed that the NexGen group was responsible for 80% of the significant values. The range of knee flexion was much smaller in this group, resulting in smaller anterior-posterior translations and rotations. Conclusion: Despite kinematics being generally consistent with the kinematics intended by their design, there were no clear recognizable differences in in vivo kinematics between different design parameters or prostheses. Hence, the differences in design parameters or prostheses are not distinct enough to have an effect on clinical outcome of patients.Biomechanical EngineeringMechanical, Maritime and Materials Engineerin

    Ninety-day complication rate based on 532 Latarjet procedures in Dutch hospitals with different operation volumes

    Get PDF
    Background: In this study, we aimed to provide insight into the 90-day complication rates following the Latarjet procedure. Data from 2015 were collected from multiple hospitals in the Netherlands, with different volumes of Latarjet procedures. Our second aim was to examine which patient and surgical factors were associated with complications.Methods: We conducted a retrospective chart review of 13 hospitals between 2015 and 2022. Data regarding complications within 90 days of Latarjet procedures were extracted. The effect of sex, age, body mass index (BMI), smoking, previous shoulder operations, fixation material, hospital volume, screw size, and operation time on the complication rate was assessed by multivariable logistic regression analysis.Results: Of the 532 included patients, 58 (10.9%) had complications. The most common complications were material failure (n = 19, 3.6%) and nerve injury (n = 13, 2.4%). The risk of complications was lower for male patients than for female patients (odds ratio, 0.40; 95% confidence interval, 0.21-0.77; P = .006). Age, BMI, smoking, previous shoulder operations, type of fixation material, hospital volume, screw size, and operation time were not associated with complications.Conclusion: The 90-day complication rate after the Latarjet procedure was 10.9% and was higher in female patients than in male patients. Age, BMI, smoking, previous shoulder operations, type of fixation material, hospital volume, screw size, and operation time did not affect complication rates. We advise setting up a national registry to prevent under-reporting of complications.</p

    Immunogenicity of a Promiscuous T Cell Epitope Peptide Based Conjugate Vaccine against Benzo[a]pyrene: Redirecting Antibodies to the Hapten

    Get PDF
    The prototype polycyclic aromatic hydrocarbon benzo[a]pyrene (B[a]P) is an environmental pollutant and food contaminant of epidemiological importance. To protect against adverse effects of this ubiquitous carcinogen, we developed an immunoprophylactic strategy based on a B[a]P-protein conjugate vaccine to induce B[a]P specific antibodies (Grova et al., Vaccine. 2009;27:4142–51). Here, we investigated in mice the efficacy of B[a]P-peptide conjugates based on promiscuous T cell epitopes (TCE) into further improve this approach. We showed that B[a]P-peptide conjugates induced very different levels of hapten-specific antibodies with variable functional efficacy, depending on the carrier. In some cases peptide carriers induced a more efficient antibody response against B[a]P than tetanus toxoid as a protein carrier, with the capacity to sequester more B[a]P in the blood. Reducing the carrier size to a single TCE can dramatically shift the antibody bias from the carrier to the B[a]P. Conjugates based on the TCE FIGITEL induced the best anti-hapten response and no antibodies against the carrier peptide. Some peptide conjugates increased the selectivity of the antibodies for the activated metabolite 7,8-diol-B[a]P and B[a]P by one or two orders of magnitude. The antibody efficacy was also demonstrated in their ability to sequester B[a]P in the blood and modulate its faecal excretion (15–56%). We further showed that pre-existing immunity to the carrier from which the TCE was derived did not reduce the immunogenicity of the peptide conjugate. In conclusion, we showed that a vaccination against B[a]P using promiscuous TCEs of tetanus toxin as carriers is feasible even in case of a pre-existing immunity to the toxoid and that some TCE epitopes dramatically redirect the antibody response to the hapten. Further studies to demonstrate a long-term protection of an immunoprophylactic immunisation against B[a]P are warranted

    Evaluation of serum MMP-9 as predictive biomarker for antisense therapy in Duchenne

    Get PDF
    Duchenne Muscular Dystrophy (DMD) is a severe muscle disorder caused by lack of dystrophin. Predictive biomarkers able to anticipate response to the therapeutic treatments aiming at dystrophin re-expression are lacking. The objective of this study is to investigate Matrix Metalloproteinase-9 (MMP-9) as predictive biomarker for Duchenne. Two natural history cohorts were studied including 168 longitudinal samples belonging to 66 patients. We further studied 1536 samples obtained from 3 independent clinical trials with drisapersen, an antisense oligonucleotide targeting exon 51: an open label study including 12 patients; a phase 3 randomized, double blind, placebo controlled study involving 186 patients; an open label extension study performed after the phase 3. Analysis of natural history cohorts showed elevated MMP-9 levels in patients and a significant increase over time in longitudinal samples. MMP-9 decreased in parallel to clinical stabilization in the 12 patients involved in the open label study. The phase 3 study and subsequent extension study clarified that the decrease in MMP-9 levels was not predictive of treatment response. These data do not support the inclusion of serum MMP-9 as predictive biomarker for DMD patients
    corecore