80 research outputs found

    Repeated delivery of chlorhexidine chips for the treatment of periimplantitis: A multicenter, randomized, comparative clinical trial.

    Get PDF
    "This is the peer reviewed version of the following article:Machtei, EE, Romanos, G, Kang, P, et al. Repeated delivery of chlorhexidine chips for the treatment of periimplantitis: A multicenter, randomized, comparative clinical trial. J Periodontol. 2020; 1– 10. https://doi.org/10.1002/JPER.20-0353 which has been published in final form at doi: https://doi.org/10.1002/JPER.20-0353 . This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions."BACKGROUND: Periimplantitis is a challenging condition to manage and is frequently treated using non-surgical debridement. The local delivery of antimicrobial agents has demonstrated benefit in mild to moderate cases of periimplantitis. This study compared the safety and efficacy of Chlorhexidine gluconate 2.5 mg chip (CHX chips) as an adjunctive treatment to sub-gingival debridement in patients afflicted with periimplantitis. METHODS: A multi-center, randomized, single-blind, two-arm, parallel Phase-3 study was conducted. Periimplantitis patients with implant pocket depths (IPD) of 5-8 mm underwent sub-gingival implant surface debridement followed by repeated bi-weekly supra-gingival plaque removal and Chlorhexidine chips application (ChxC group) for 12 weeks, or similar therapy but without application of ChxC (control group). All patients were followed for 24 weeks. Plaque and gingival indices were measured at every visit while IPD, recession and bleeding on probing were assessed at 8,12,16,24 week. RESULTS: 290 patients were included: 146 in the ChxC group and 144 in the control. At 24 weeks, a significant reduction in IPD (p = 0.01) was measured in the ChxC group (1.76 ± 1.13 mm) compared to the control group (1.54 ± 1.13 mm). IPD reduction of ≥2 mm was found in 59% and 47.2% of the implants in the ChxC and control groups, respectively (p = 0.03). Changes in gingival recession (0.29 ± 0.68 mm vs. 0.15 ± 0.55 mm, p = 0.015) and relative attachment gain (1.47 ± 1.32 mm and 1.39 ± 1.27 mm, p = 0.0017) were significantly larger in the ChxC group. Patients in the ChxC group that were <65 years exhibited significantly better responses (p<0.02); likewise, non-smokers had similarly better response (p <0.02). Both protocols were well tolerated, and no severe treatment-related adverse events were recorded throughout the study. CONCLUSIONS: Patients with periimplantitis that were treated with an intensive treatment protocol of bi-weekly supra-gingival plaque removal and local application of Chlorhexidine chips had greater mean IPD reduction and greater percentile of sites with IPD reduction of ≥2 mm. as compared to bi-weekly supra-gingival plaque removal. (Clinicaltrials.gov NCT02080403). This article is protected by copyright. All rights reserved

    Blood flow changes using a 3D xenogeneic collagen matrix or a subepithelial connective tissue graft for root coverage procedures: a pilot study.

    Get PDF
    BACKGROUND: The study investigated the early healing process following the treatment of single Miller class I and II recessions with a 3D xenogeneic collagen matrix (CMX) or connective tissue graft (CTG). METHODS: This pilot investigation was designed as a single-center randomized controlled parallel trial. A total of eight subjects (four per group) were treated with either CMX or CTG in the anterior maxilla. Vascular flow changes were assessed by laser Doppler flowmetry (LDF) before and after surgery and at days 1, 2, 3, 7, 14, and 30 while clinical evaluations took place at baseline and at days 60 and 180. Pain intensity perception was evaluated by the short-form McGill pain questionnaire (SF-MPQ), at days 1 and 14. RESULTS: The vascular flow fluctuated similarly in both groups pre- and post-operatively, but the CTG exhibited a more homogeneous pattern as opposed to CMX that showed a second phase of increased blood flow at 14 days. Clinically, the CTG led to greater change in mean root coverage and keratinized tissue gain but CMX was associated with lower early pain intensity scores. CONCLUSIONS: Within the limits of the study, the vascular flow alterations during the early healing of both graft types followed a similar pattern. The CMX was associated with a second peak of increased blood flow. CLINICAL RELEVANCE: The vascular flow changes after the application of CMX for single tooth recession root coverage did not show major differences from those observed after the use of a CTG. A trend for better clinical performance in terms of root coverage and keratinized tissue gain was noted for the CTG, but the initial patient morbidity was less for CMX

    A TREM2-activating antibody with a blood-brain barrier transport vehicle enhances microglial metabolism in Alzheimer's disease models

    Get PDF
    van Lengerich et al. developed a human TREM2 antibody with a transport vehicle (ATV) that improves brain exposure and biodistribution in mouse models. ATV:TREM2 promotes microglial energetic capacity and metabolism via mitochondrial pathways. Loss-of-function variants of TREM2 are associated with increased risk of Alzheimer's disease (AD), suggesting that activation of this innate immune receptor may be a useful therapeutic strategy. Here we describe a high-affinity human TREM2-activating antibody engineered with a monovalent transferrin receptor (TfR) binding site, termed antibody transport vehicle (ATV), to facilitate blood-brain barrier transcytosis. Upon peripheral delivery in mice, ATV:TREM2 showed improved brain biodistribution and enhanced signaling compared to a standard anti-TREM2 antibody. In human induced pluripotent stem cell (iPSC)-derived microglia, ATV:TREM2 induced proliferation and improved mitochondrial metabolism. Single-cell RNA sequencing and morphometry revealed that ATV:TREM2 shifted microglia to metabolically responsive states, which were distinct from those induced by amyloid pathology. In an AD mouse model, ATV:TREM2 boosted brain microglial activity and glucose metabolism. Thus, ATV:TREM2 represents a promising approach to improve microglial function and treat brain hypometabolism found in patients with AD

    Association between metabolic syndrome and periodontitis: a systematic review and meta-analysis

    No full text
    Background: Several epidemiological studies have reported an association between metabolic syndrome (MetS) and periodontal diseases (PDs). The aim of this systematic review was to investigate the existence and magnitude of this association. Materials and Methods: A systematic search of the literature was conducted looking for casecontrol, cross-sectional, cohort studies and population surveys including patients with measures of MetS and PD. Ovid MEDLINE, EMBASE, LILACS, and Cochrane library databases were used for the search by 2 independent reviewers. A meta-analysis was conducted to investigate the association for coexistence of MetS and PD. Results: A total of 20 studies were included in the review, from an initial search of 3486 titles. Only 1 study reported longitudinal data on the onset of MetS components in association with periodontal measures. However, several studies investigated coexistence. A random effects meta-analysis showed that the presence of MetS is associated with the presence of periodontitis in a total of 36 337 subjects (odds ratio 1.71;95%confidence interval 1.42 to 2.03).Whenonly studies with “secure” diagnoses wereincluded (n=16 405), themagnitudeof association increased (odds ratio=2.09;95%confidence interval = 1.28 to 3.44). Moderate heterogeneity was detected (I2 =53.6%; P = .004). Conclusions: This review presents clear evidence for an association between MetS and periodontitis. The direction of the association and factors influencing it should be investigated by longitudinal and treatment studies. Periodontal diagnostic procedures should be routinely carried out in MetS patient

    Enhanced harmonic conversion efficiency in the self-guided propagation of femtosecond ultraviolet laser pulses in argon

    No full text
    International audienceHarmonic generation during the self-guided propagation of femtosecond ultraviolet (UV) laser pulses (248-nm, 450-fs) in argon is investigated. The third (82.7-nm) and fifth (49.6-nm) harmonics are generated in the UV filament. The energy-conversion efficiencies for the harmonics are found to be at least two orders of magnitude higher than those reported in the literature for similar gas pressures. The enhancement is attributed to the quasi-phase matching of the harmonics due to the self-guiding of the driving pulse

    An evaluation of sustainability and societal impact of high-power laser and fusion technologies: a case for a new European research infrastructure

    Get PDF
    Fusion energy research is delivering impressive new results emerging from different infrastructures and industrial devices evolving rapidly from ideas to proof-of-principle demonstration and aiming at the conceptual design of reactors for the production of electricity. A major milestone has recently been announced in laser fusion by the Lawrence Livermore National Laboratory and is giving new thrust to laser-fusion energy research worldwide. Here we discuss how these circumstances strongly suggest the need for a European intermediate-energy facility dedicated to the physics and technology of laser-fusion ignition, the physics of fusion materials and advanced technologies for high-repetition-rate, high-average-power broadband lasers. We believe that the participation of the broader scientific community and the increased engagement of industry, in partnership with research and academic institutions, make most timely the construction of this infrastructure of extreme scientific attractiveness

    High performance simulations of a single X-pinch

    No full text
    International audienceThe dynamics of plasmas produced by low current X-pinch devices are explored. This comprehensive computational study is the first step in the preparation of an experimental campaign aiming to understand the formation of plasma jets in table-top pulsed power X-pinch devices. Two state-of-the-art magneto-hydro-dynamic codes, GORGON and PLUTO, are used to simulate the evolution of the plasma and describe its key dynamic features. GORGON and PLUTO are built on different approximation schemes and the simulation results obtained are discussed and analyzed in relation to the physics adopted by each code. Both codes manage to accurately handle the numerical demands of the X-pinch plasma evolution and provide precise details on the mechanisms of the plasma expansion, the jet-formation, and the pinch generation. Furthermore, the influence of electrical resistivity, radiation transport and optically thin losses on the dynamic behaviour of the simulated X-pinch produced plasma is studied in PLUTO. Our findings highlight the capabilities of the GORGON and PLUTO codes in simulating the wide range of plasma conditions found in X-pinch experiments, enabling a direct comparison to the scheduled experiments
    corecore