310 research outputs found
LIMO EEG: A Toolbox for hierarchical LInear MOdeling of ElectroEncephaloGraphic data
Magnetic- and electric-evoked brain responses have traditionally been analyzed by comparing the peaks or mean amplitudes of signals from selected channels and averaged across trials. More recently, tools have been developed to investigate single trial response variability (e.g., EEGLAB) and to test differences between averaged evoked responses over the entire scalp and time dimensions (e.g., SPM, Fieldtrip). LIMO EEG is a Matlab toolbox (EEGLAB compatible) to analyse evoked responses over all space and time dimensions, while accounting for single trial variability using a simple hierarchical linear modelling of the data. In addition, LIMO EEG provides robust parametric tests, therefore providing a new and complementary tool in the analysis of neural evoked responses
Age-related delay in information accrual for faces: Evidence from a parametric, single-trial EEG approach
Background: In this study, we quantified age-related changes in the time-course of face processing
by means of an innovative single-trial ERP approach. Unlike analyses used in previous studies, our
approach does not rely on peak measurements and can provide a more sensitive measure of
processing delays. Young and old adults (mean ages 22 and 70 years) performed a non-speeded
discrimination task between two faces. The phase spectrum of these faces was manipulated
parametrically to create pictures that ranged between pure noise (0% phase information) and the
undistorted signal (100% phase information), with five intermediate steps.
Results: Behavioural 75% correct thresholds were on average lower, and maximum accuracy was
higher, in younger than older observers. ERPs from each subject were entered into a single-trial
general linear regression model to identify variations in neural activity statistically associated with
changes in image structure. The earliest age-related ERP differences occurred in the time window
of the N170. Older observers had a significantly stronger N170 in response to noise, but this age
difference decreased with increasing phase information. Overall, manipulating image phase
information had a greater effect on ERPs from younger observers, which was quantified using a
hierarchical modelling approach. Importantly, visual activity was modulated by the same stimulus
parameters in younger and older subjects. The fit of the model, indexed by R2, was computed at
multiple post-stimulus time points. The time-course of the R2 function showed a significantly slower
processing in older observers starting around 120 ms after stimulus onset. This age-related delay
increased over time to reach a maximum around 190 ms, at which latency younger observers had
around 50 ms time lead over older observers.
Conclusion: Using a component-free ERP analysis that provides a precise timing of the visual
system sensitivity to image structure, the current study demonstrates that older observers
accumulate face information more slowly than younger subjects. Additionally, the N170 appears to
be less face-sensitive in older observers
Fundamental limitations for quantum and nano thermodynamics
The relationship between thermodynamics and statistical physics is valid in
the thermodynamic limit - when the number of particles becomes very large.
Here, we study thermodynamics in the opposite regime - at both the nano scale,
and when quantum effects become important. Applying results from quantum
information theory we construct a theory of thermodynamics in these limits. We
derive general criteria for thermodynamical state transformations, and as
special cases, find two free energies: one that quantifies the
deterministically extractable work from a small system in contact with a heat
bath, and the other that quantifies the reverse process. We find that there are
fundamental limitations on work extraction from nonequilibrium states, owing to
finite size effects and quantum coherences. This implies that thermodynamical
transitions are generically irreversible at this scale. As one application of
these methods, we analyse the efficiency of small heat engines and find that
they are irreversible during the adiabatic stages of the cycle.Comment: Final, published versio
Hemodynamic and antifibrotic effects of a selective liver nitric oxide donor V-PYRRO/NO in bile duct ligated rats.
AIM: To assess whether a liver specific nitric oxide (NO) donor (V-PYRRO/NO) would prevent the development of portal hypertension and liver fibrosis in rats with bile duct ligation (BDL).
METHODS: Treatment (placebo or V-PYRRO/NO 0.53 micromol/kg per hour) was administered i.v. to rats 2 d before BDL (D-2) and maintained until the day of hemodynamic measurement (D26). Intra-hepatic NO level was estimated by measuring liver cGMP level. Effects of V-PYRRO/NO on liver fibrosis and lipid peroxidation were also assessed.
RESULTS: Compared to placebo treatment, V-PYRRO/NO improved splanchnic hemodynamics in BDL rats: portal pressure was significantly reduced by 27% (P<0.0001) and collateral circulation development was almost completely blocked (splenorenal shunt blood flow by 74%, P=0.007). Moreover, V-PYRRO/NO significantly prevented liver fibrosis development in BDL rats (by 30% in hepatic hydroxyproline content and 31% in the area of fibrosis, P<0.0001 respectively), this effect being probably due to a decrease in lipid peroxidation by 44% in the hepatic malondialdehyde level (P=0.007). Interestingly, we observed a significant and expected increase in liver cGMP, without any systemic hemodynamic effects (mean arterial pressure, vascular systemic resistance and cardiac output) in both sham-operated and BDL rats treated with V-PYRRO/NO. This result is in accordance with studies on V-PYRRO/NO metabolism showing a specific release of NO in the liver.
CONCLUSION: Continuous administrations of V-PYRRO/NO in BDL rats improved liver fibrosis and splanchnic hemodynamics without any noxious systemic hemo-dynamic effects
Determination of reliability criteria for liver stiffness evaluation by transient elastography
UNLABELLED: Liver stiffness evaluation (LSE) is usually considered as reliable when it fulfills all the following criteria: ≥10 valid measurements, ≥60% success rate, and interquartile range / median ratio (IQR/M) ≤0.30. However, such reliable LSE have never been shown to be more accurate than unreliable LSE. Thus, we aimed to evaluate the relevance of the usual definition for LSE reliability, and to improve reliability by using diagnostic accuracy as a primary outcome in a large population. 1,165 patients with chronic liver disease from 19 French centers were included. All patients had liver biopsy and LSE. 75.7% of LSE were reliable according to the usual definition. However, these reliable LSE were not significantly more accurate than unreliable LSE with, respectively: 85.8% versus 81.5% well-classified patients for the diagnosis of cirrhosis (P = 0.082). In multivariate analyses with different diagnostic targets, LSE median and IQR/M were independent predictors of fibrosis staging, with no significant influence of ≥10 valid measurements or LSE success rate. These two reliability criteria determined three LSE groups: "very reliable" (IQR/M ≤0.10), "reliable" (0.10< IQR/M ≤0.30, or IQR/M >0.30 with LSE median <7.1 kPa), and "poorly reliable" (IQR/M >0.30 with LSE median ≥7.1 kPa). The rates of well-classified patients for the diagnosis of cirrhosis were, respectively: 90.4%, 85.8%, and 69.5% (P < 10(-3) ). According to these new reliability criteria, 9.1% of LSE were poorly reliable (versus 24.3% unreliable LSE with the usual definition, P < 10(-3) ), 74.3% were reliable, and 16.6% were very reliable.
CONCLUSION: The usual definition for LSE reliability is not relevant. LSE reliability depends on IQR/M according to liver stiffness median level, defining thus three reliability categories: very reliable, reliable, and poorly reliable LSE. (HEPATOLOGY 2013)
The combination of a blood test and Fibroscan improves the non-invasive diagnosis of liver fibrosis
Background and aims: Blood tests and liver stiffness evaluation (LSE) by ultrasonographic elastometry are accurate tools for diagnosing liver fibrosis. We evaluated whether their synchronous combination in new scores could improve the diagnostic accuracy and reduce liver biopsy requirement in algorithm. Methods: Three hundred and ninety patients with chronic liver disease of miscellaneous causes were included. Five blood fibrosis tests were evaluated: APRI, FIB-4, Hepascore, Fibrotest and FibroMeter. The reference was fibrosis Metavir staging. Results: Diagnosis of significant fibrosis (Metavir F≥2). The most accurate synchronous combination was FibroMeter+LSE, which provided a significantly higher area under the receiver operating characteristic curve (0.892) than LSE alone (0.867, P=0.011) or Fibrometer (0.834, P<10−3). An algorithm using the FibroMeter+LSE combination and then a liver biopsy in indeterminate cases had 91.9% diagnostic accuracy and required significantly fewer biopsies (20.2%) than previously published Bordeaux algorithm (28.6%, P=0.02) or sequential algorithm for fibrosis evaluation (SAFE) (55.7%, P<10−3). The Angers algorithm performance was not significantly different between viral hepatitis and other causes. Diagnosis of cirrhosis. The most accurate synchronous combination was LSE+FibroMeter, which provided ≥90% predictive values for cirrhosis in 90.6% of patients vs 87.4% for LSE (P=0.02) and 57.9% for FibroMeter (P<10−3). An algorithm including the LSE+FibroMeter combination, and then a liver biopsy in indeterminate cases, had a significantly higher diagnostic accuracy than the SAFE algorithm (91.0 vs 79.8%, P<10−3), and required significantly fewer biopsies than the Bordeaux algorithm (9.3 vs 25.3%, P<10−3). Conclusion: The synchronous combination of a blood test plus LSE improves the accuracy of the non-invasive diagnosis of liver fibrosis and, consequently, markedly decreases the biopsy requirement in the diagnostic algorithm, notably to <10% in cirrhosis diagnosis
Feynman's ratchet and pawl: an exactly solvable model
We introduce a simple, discrete model of Feynman's ratchet and pawl,
operating between two heat reservoirs. We solve exactly for the steady-state
directed motion and heat flows produced, first in the absence and then in the
presence of an external load. We show that the model can act both as a heat
engine and as a refrigerator. We finally investigate the behavior of the system
near equilibrium, and use our model to confirm general predictions based on
linear response theory.Comment: 19 pages + 10 figures; somewhat tighter presentatio
Effect of Chaotic Noise on Multistable Systems
In a recent letter [Phys.Rev.Lett. {\bf 30}, 3269 (1995), chao-dyn/9510011],
we reported that a macroscopic chaotic determinism emerges in a multistable
system: the unidirectional motion of a dissipative particle subject to an
apparently symmetric chaotic noise occurs even if the particle is in a
spatially symmetric potential. In this paper, we study the global dynamics of a
dissipative particle by investigating the barrier crossing probability of the
particle between two basins of the multistable potential. We derive
analytically an expression of the barrier crossing probability of the particle
subject to a chaotic noise generated by a general piecewise linear map. We also
show that the obtained analytical barrier crossing probability is applicable to
a chaotic noise generated not only by a piecewise linear map with a uniform
invariant density but also by a non-piecewise linear map with non-uniform
invariant density. We claim, from the viewpoint of the noise induced motion in
a multistable system, that chaotic noise is a first realization of the effect
of {\em dynamical asymmetry} of general noise which induces the symmetry
breaking dynamics.Comment: 14 pages, 9 figures, to appear in Phys.Rev.
Characterizing closure-phase measurements at IOTA
We are working towards imaging the surfaces and circumstellar envelopes of Mira stars in the near-infrared, using the IOTA interferometer and the IONIC integrated-optics 3-beam combiner. In order to study atmospheric structures of these stars, we installed 3 narrow-band filters that subdivide H-band into 3 roughly equal-width sub-bands - a central one for continuum, and 2 adjacent ones to sample Mira star's (mostly water) absorption-bands. We present here our characterization of the IOTA 3-Telescope interferometer for closure-phase measurements with broad and narrow-band filters in the H atmospheric window. This includes characterizing the stability, chromaticity, and polarization effects of the present IOTA optics with the IONIC beam-combiner, and characterizing the accuracy of our closure phase measurements
- …