34 research outputs found

    Endothelin Receptor A Antagonism Attenuates Renal Medullary Blood Flow Impairment in Endotoxemic Pigs

    Get PDF
    BACKGROUND: Endothelin-1 is a potent endogenous vasoconstrictor that contributes to renal microcirculatory impairment during endotoxemia and sepsis. Here we investigated if the renal circulatory and metabolic effects of endothelin during endotoxemia are mediated through activation of endothelin-A receptors. METHODS AND FINDINGS: A randomized experimental study was performed with anesthetized and mechanically ventilated pigs subjected to Escherichia coli endotoxin infusion for five hours. After two hours the animals were treated with the selective endothelin receptor type A antagonist TBC 3711 (2 mg⋅kg(-1), n = 8) or served as endotoxin-treated controls (n = 8). Renal artery blood flow, diuresis and creatinine clearance decreased in response to endotoxemia. Perfusion in the cortex, as measured by laser doppler flowmetry, was reduced in both groups, but TBC 3711 attenuated the decrease in the medulla (p = 0.002). Compared to control, TBC 3711 reduced renal oxygen extraction as well as cortical and medullary lactate/pyruvate ratios (p<0.05) measured by microdialysis. Furthermore, TBC 3711 attenuated the decline in renal cortical interstitial glucose levels (p = 0.02) and increased medullary pyruvate levels (p = 0.03). Decreased creatinine clearance and oliguria were present in both groups without any significant difference. CONCLUSIONS: These results suggest that endothelin released during endotoxemia acts via endothelin A receptors to impair renal medullary blood flow causing ischemia. Reduced renal oxygen extraction and cortical levels of lactate by TBC 3711, without effects on cortical blood flow, further suggest additional metabolic effects of endothelin type A receptor activation in this model of endotoxin induced acute kidney injury

    The Role of Endothelin-1 and Endothelin Receptor Antagonists in Inflammatory Response and Sepsis

    Get PDF

    2015/16 seasonal vaccine effectiveness against hospitalisation with influenza a(H1N1)pdm09 and B among elderly people in Europe: Results from the I-MOVE+ project

    Get PDF
    We conducted a multicentre test-negative caseâ\u80\u93control study in 27 hospitals of 11 European countries to measure 2015/16 influenza vaccine effectiveness (IVE) against hospitalised influenza A(H1N1)pdm09 and B among people aged â\u89¥ 65 years. Patients swabbed within 7 days after onset of symptoms compatible with severe acute respiratory infection were included. Information on demographics, vaccination and underlying conditions was collected. Using logistic regression, we measured IVE adjusted for potential confounders. We included 355 influenza A(H1N1)pdm09 cases, 110 influenza B cases, and 1,274 controls. Adjusted IVE against influenza A(H1N1)pdm09 was 42% (95% confidence interval (CI): 22 to 57). It was 59% (95% CI: 23 to 78), 48% (95% CI: 5 to 71), 43% (95% CI: 8 to 65) and 39% (95% CI: 7 to 60) in patients with diabetes mellitus, cancer, lung and heart disease, respectively. Adjusted IVE against influenza B was 52% (95% CI: 24 to 70). It was 62% (95% CI: 5 to 85), 60% (95% CI: 18 to 80) and 36% (95% CI: -23 to 67) in patients with diabetes mellitus, lung and heart disease, respectively. 2015/16 IVE estimates against hospitalised influenza in elderly people was moderate against influenza A(H1N1)pdm09 and B, including among those with diabetes mellitus, cancer, lung or heart diseases

    38 GHz Antennas on Micromachined Silicon Substrates.

    Get PDF
    A new configuration of a double folded double slot CPW feed micromachined antenna array was realized on a 1.5 µm thin three-layer dielectric membrane fabricated on a silicon substrate. The antenna was designed for an operating frequency of 38 GHz, and the double folded configuration was used for minimizing the membrane extension

    Resistive pressure sensing structures on polymide membranes on GaAs substrate

    No full text
    This paper presents the manufacture of a simple pressure sensing structure supported on polymide membranes obtained by micromachining of a GaAs substrate. The sensing element is a gold on chromium resistor on the polymide membrane. The technological process for the manufacturing of this structure is presented. The sensing element shows high linearity, absence of hysteresis, good sensitivity, and can be used in high-temperature application
    corecore