67 research outputs found

    Biomimetic nanocrystalline apatite coatings synthesized by Matrix Assisted Pulsed Laser Evaporation for medical applications

    Get PDF
    tWe report the deposition by Matrix Assisted Pulsed Laser Evaporation (MAPLE) technique of biomimeticnanocrystalline apatite coatings on titanium substrates, with potential application in tissue engineering.The targets were prepared from metastable, nanometric, poorly crystalline apatite powders, analogousto mineral bone, synthesized through a biomimetic approach by double decomposition process. For thedeposition of thin films, a KrF* excimer laser source was used (λ = 248 nm, τFWHM ≤ 25 ns). The analy-ses revealed the existence, in synthesized powders, of labile non-apatitic mineral ions, associated withthe formation of a hydrated layer at the surface of the nanocrystals. The thin film analyses showedthat the structural and chemical nature of the nanocrystalline apatite was prevalently preserved. Theperpetuation of the non-apatitic environments was also observed. The study indicated that MAPLE isa suitable technique for the congruent transfer of a delicate material, such as the biomimetic hydratednanohydroxyapatite

    Modern microwave methods in solid state inorganic materials chemistry: from fundamentals to manufacturing

    Get PDF
    No abstract available

    Combinatorial MAPLE deposition of antimicrobial orthopedic maps fabricated from chitosan and biomimetic apatite powders

    Get PDF
    Chitosan/biomimetic apatite thin films were grown in mild conditions of temperature and pressure by Combinatorial Matrix-Assisted Pulsed Laser Evaporation on Ti, Si or glass substrates. Compositional gradients were obtained by simultaneous laser vaporization of the two distinct material targets. A KrF* excimer (λ=248nm, τFWHM=25ns) laser source was used in all experiments. The nature and surface composition of deposited materials and the spatial distribution of constituents were studied by SEM, EDS, AFM, GIXRD, FTIR, micro-Raman, and XPS. The antimicrobial efficiency of the chitosan/biomimetic apatite layers against Staphylococcus aureus and Escherichia coli strains was interrogated by viable cell count assay. The obtained thin films were XRD amorphous and exhibited a morphology characteristic to the laser deposited structures composed of nanometric round shaped grains. The surface roughness has progressively increased with chitosan concentration. FTIR, EDS and XPS analyses indicated that the composition of the BmAp-CHT C-MAPLE composite films gradually modified from pure apatite to chitosan. The bioevaluation tests indicated that S. aureus biofilm is more susceptible to the action of chitosan-rich areas of the films, whilst the E. coli biofilm proved more sensible to areas containing less chitosan. The best compromise should therefore go, in our opinion, to zones with intermediate-to-high chitosan concentration which can assure a large spectrum of antimicrobial protection concomitantly with a significant enhancement of osseointegration, favored by the presence of biomimetic hydroxyapatite

    Hybrid Titanium/Biodegradable Polymer Implants with an Hierarchical Pore Structure as a Means to Control Selective Cell Movement

    Get PDF
    UNLABELLED: In order to improve implant success rate, it is important to enhance their responsiveness to the prevailing conditions following implantation. Uncontrolled movement of inflammatory cells and fibroblasts is one of these in vivo problems and the porosity properties of the implant have a strong effect on these. Here, we describe a hybrid system composed of a macroporous titanium structure filled with a microporous biodegradable polymer. This polymer matrix has a distinct porosity gradient to accommodate different cell types (fibroblasts and epithelial cells). The main clinical application of this system will be the prevention of restenosis due to excessive fibroblast migration and proliferation in the case of tracheal implants. METHODOLOGY/PRINCIPAL FINDINGS: A microbead-based titanium template was filled with a porous Poly (L-lactic acid) (PLLA) body by freeze-extraction method. A distinct porosity difference was obtained between the inner and outer surfaces of the implant as characterized by image analysis and Mercury porosimetry (9.8±2.2 µm vs. 36.7±11.4 µm, p≤0.05). On top, a thin PLLA film was added to optimize the growth of epithelial cells, which was confirmed by using human respiratory epithelial cells. To check the control of fibroblast movement, PKH26 labeled fibroblasts were seeded onto Titanium and Titanium/PLLA implants. The cell movement was quantified by confocal microscopy: in one week cells moved deeper in Ti samples compared to Ti/PLLA. CONCLUSIONS: In vitro experiments showed that this new implant is effective for guiding different kind of cells it will contact upon implantation. Overall, this system would enable spatial and temporal control over cell migration by a gradient ranging from macroporosity to nanoporosity within a tracheal implant. Moreover, mechanical properties will be dependent mainly on the titanium frame. This will make it possible to create a polymeric environment which is suitable for cells without the need to meet mechanical requirements with the polymeric structure

    Glycosylation of Erythrocyte Spectrin and Its Modification in Visceral Leishmaniasis

    Get PDF
    Using a lectin, Achatinin-H, having preferential specificity for glycoproteins with terminal 9-O-acetyl sialic acid derivatives linked in α2-6 linkages to subterminal N-acetylgalactosamine, eight distinct disease-associated 9-O-acetylated sialoglycoproteins was purified from erythrocytes of visceral leishmaniaisis (VL) patients (RBCVL). Analyses of tryptic fragments by mass spectrometry led to the identification of two high-molecular weight 9-O-acetylated sialoglycoproteins as human erythrocytic α- and β-spectrin. Total spectrin purified from erythrocytes of VL patients (spectrinVL) was reactive with Achatinin-H. Interestingly, along with two high molecular weight bands corresponding to α- and β-spectrin another low molecular weight 60 kDa band was observed. Total spectrin was also purified from normal human erythrocytes (spectrinN) and insignificant binding with Achatinin-H was demonstrated. Additionally, this 60 kDa fragment was totally absent in spectrinN. Although the presence of both N- and O-glycosylations was found both in spectrinN and spectrinVL, enhanced sialylation was predominantly induced in spectrinVL. Sialic acids accounted for approximately 1.25 kDa mass of the 60 kDa polypeptide. The demonstration of a few identified sialylated tryptic fragments of α- and β-spectrinVL confirmed the presence of terminal sialic acids. Molecular modelling studies of spectrin suggest that a sugar moiety can fit into the potential glycosylation sites. Interestingly, highly sialylated spectrinVL showed decreased binding with spectrin-depleted inside-out membrane vesicles of normal erythrocytes compared to spectrinN suggesting functional abnormality. Taken together this is the first report of glycosylated eythrocytic spectrin in normal erythrocytes and its enhanced sialylation in RBCVL. The enhanced sialylation of this cytoskeleton protein is possibly related to the fragmentation of spectrinVL as evidenced by the presence of an additional 60 kDa fragment, absent in spectrinN which possibly affects the biology of RBCVL linked to both severe distortion of erythrocyte development and impairment of erythrocyte membrane integrity and may provide an explanation for their sensitivity to hemolysis and anemia in VL patients

    Influence de la géomembrane sur les mesures ERT en suivi temporel pour le suivi d'injection de lixiviat

    No full text
    International audienceLeachate recirculation is a key process in the operation of municipal waste landfills as bioreactors. To quantify the water content and to evaluate the leachate injection system, in situ methods are required to obtain spatially distributed information, usually electrical resistivity tomography (ERT). However, this method can present false variations in the observations due to several parameters. This study investigates the impact of the geomembrane on ERT measurements. Indeed, the geomembrane tends to be ignored in the inversion process in most previously conducted studies. The presence of the geomembrane can change the boundary conditions of the inversion models, which have classically infinite boundary conditions. Using a numerical modelling approach, the authors demonstrate that a minimum distance is required between the electrode line and the geomembrane to satisfy the good conditions of use of the classical inversion tools. This distance is a function of the electrode line length (i.e. of the unit electrode spacing) used, the array type and the orientation of the electrode line. Moreover, this study shows that if this criterion on the minimum distance is not satisfied, it is possible to significantly improve the inversion process by introducing the complex geometry and the geomembrane location into the inversion tools. These results are finally validated on a field data set gathered on a small municipal solid waste landfill cell where this minimum distance criterion cannot be satisfied
    • …
    corecore