21 research outputs found

    Patient-specific image-based computer simulation for theprediction of valve morphology and calcium displacement after TAVI with the Medtronic CoreValve and the Edwards SAPIEN valve

    Get PDF
    AIMS: Our aim was to validate patient-specific software integrating baseline anatomy and biomechanical properties of both the aortic root and valve for the prediction of valve morphology and aortic leaflet calcium displacement after TAVI. METHODS AND RESULTS: Finite element computer modelling was performed in 39 patients treated with a Medtronic CoreValve System (MCS; n=33) or an Edwards SAPIEN XT (ESV; n=6). Quantitative axial frame morphology at inflow (MCS, ESV) and nadir, coaptation and commissures (MCS) was compared between multislice computed tomography (MSCT) post TAVI and a computer model as well as displacement of the aortic leaflet calcifications, quantified by the distance between the coronary ostium and the closest calcium nodule. Bland-Altman analysis revealed a strong correlation between the observed (MSCT) and predicted frame dimensions, although small differences were detected for, e.g., Dmin at the inflow (mean±SD MSCT vs. MODEL: 21.6±2.4 mm vs. 22.0±2.4 mm; difference±SD: -0.4±1.3 mm, p<0.05) and Dmax (25.6±2.7 mm vs. 26.2±2.7 mm; difference±SD: -0.6±1.0 mm, p<0.01). The observed and predicted calcium displacements were highly correlated for the left and right coronary ostia (R2=0.67 and R2=0.71, respectively p<0.001). CONCLUSIONS: Dedicated software allows accurate prediction of frame morphology and calcium displacement after valve implantation, which may help to improve outcome

    Determinants of image quality of rotational angiography for on-line assessment of frame geometry after transcatheter aortic valve implantation

    Get PDF
    To study the determinants of image quality of rotational angiography using dedicated research prototype software for motion compensation without rapid ventricular pacing after the implantation of four commercially available catheter-based valves. Prospective observational study including 179 consecutive patients who underwent transcatheter aortic valve implantation (TAVI) with either the Medtronic CoreValve (MCS), Edward-SAPIEN Valve (ESV), Boston Sadra Lotus (BSL) or Saint-Jude Portico Valve (SJP) in whom rotational angiography (R-angio) with motion compensation 3D image reconstruction was performed. Image quality was evaluated from grade 1 (excellent image quality) to grade 5 (strongly degraded). Distinction was made between good (grades 1, 2) and poor image quality (grades 3–5). Clinical (gender, body mass index, Agatston score, heart rate and rhythm, artifacts), procedural (valve type) and technical variables (isocentricity) were related with the image quality assessment. Image quality was good in 128 (72 %) and poor in 51 (28 %) patients. By univariable analysis only valve type (BSL) and the presence of an artefact negatively affected image quality. By multivariate analysis (in which BMI was forced into the model) BSL valve (Odds 3.5, 95 % CI [1.3–9.6], p = 0.02), presence of an artifact (Odds 2.5, 95 % CI [1.2–5.4], p = 0.02) and BMI (Odds 1.1, 95 % CI [1.0–1.2], p = 0.04) were independent predictors of poor image quality. Rotational angiography with motion compensation 3D image reconstruction using a dedicated research prototype software offers good image quality for the evaluation of frame geometry after TAVI in the majority of patients. Valve type, presence of artifacts and higher BMI negatively affect image quality

    Prevalence and consequences of noncardiac incidental findings on preprocedural imaging in the workup for transcatheter aortic valve implantation, renal sympathetic denervation, or MitraClip implantation

    Get PDF
    Background: Dedicated data on the prevalence of incidental findings (IF) stratified according to overall clinical relevance and their subsequent correlation to outcome are lacking. The aim of the present study was to describe the prevalence and consequences of noncardiac IF on computed tomography or magnetic resonance imaging in the workup for interventional cardiovascular procedures. Methods: A total of 916 patients underwent preprocedural computed tomography or magnetic resonance imaging in the workup for transcatheter aortic valve implantation (TAVI), renal sympathetic denervation (RDN), or MitraClip implantation. Results: IF were found in 395 of 916 patients (43.1%), with an average of 1.8 IF per patient. Classifying the IF resulted in 155 patients with minor, 171 patients with moderate, and 69 patients with major IF. The intended procedure was delayed or canceled in only 15 of 916 (1.6%) of the patients because of the presence of potential malignant IF. In patients that did undergo the intended procedure (n = 774), the presence of a moderate or major IF (23.8%) did not impact 1-year mortality compared to no or minor IF (adjusted HR 0.90, 95% CI 0.56-1.44, P value =.65). These findings were consistent among patients referred for TAVI, RDN, or MitraClip. Conclusions: IF are frequent in patients referred for cardiovascular procedures. IF did not result in a delay or cancellation of the intended procedure in the vast majority of cases, irrespective of their clinical relevance. The presence of a major or moderate IF did not significantly impact 1-year mortality

    Clinical consequences of consecutive self-expanding transcatheter heart valve iterations

    Get PDF
    OBJECTIVE: To compare early clinical outcomes after transcatheter aortic valve implantation (TAVI) with three consecutive generations of self-expanding valves (SEVs). METHODS: Clinical endpoints of consecutive patients who underwent TAVI with CoreValve, Evolut R or Evolut PRO were included in a prospective database. RESULTS: TAVI was performed with CoreValve (n = 116), Evolut R (n = 160) or Evolut PRO (n = 92). Evolut R and Evolut PRO showed a tendency towards lower permanent pacemaker implantation (PPI) rates compared to CoreValve (CoreValve 27% vs Evolut R 16% vs Evolut PRO 18%, p = 0.091). By multivariable regression analysis CoreValve had a significantly higher risk for PPI (odds ratio (OR) 2.79, 95% confidence interval (CI) 1.31–5.94, p = 0.008) compared to Evolut R, while Evolut R and PRO were similar. Severe paravalvular leakage (PVL) occurred only with CoreValve, but no significant difference was observed in moderate PVL (10% vs 8% vs 6%, p = 0.49). CoreValve had a tendency towards a higher risk for more-than-mild PVL as compared with the Evolut platform (R + PRO) (OR 2.46, 95% CI 0.98–6.16, p = 0.055). No significant differences in all-cause mortality (7% vs 4% vs 1%, p = 0.10), stroke (6% vs 3% vs 2%, p = 0.21) or major vascular complications (10% vs 12% vs 4%, p = 0.14) were observed. CONCLUSIONS: TAVI with self-expanding valves was safe, and device iterations may result in a lower need for PPI. More-than-mild PVL seemed to occur less often with repositionable technology. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s12471-021-01568-5) contains supplementary material, which is available to authorized users

    Long-term follow-up of quality of life in high-risk patients undergoing transcatheter aortic valve implantation for symptomatic aortic valve stenosis

    Get PDF
    Background Transcatheter aortic valve implantation (TAVI) has become the standard treatment for patients with severe symptomatic aortic stenosis (AS) considered at very high risk for surgical aortic valve replacement. The purpose of this sub-study was to evaluate long-term (> 4 years) health-related quality of life (QoL) in octogenarians who underwent TAVI. Methods A single center observational registry in twenty patients who underwent frame analysis assessment = 4 years after TAVI. Health-related QoL was evaluated, using the Short Form-36 (SF-36), the EuroQoL-5D (EQ-5D) and the visual analogue score (EQ-VAS) questionnaires. Results The mean SF-36 subscale scores at follow-up were physical functioning 40.8 ± 26.3, role physical functioning 67.7 ± 34.9, vitality 54.6 ± 21.6, general health 52.1 ± 20.4, social functioning 63.8 ± 37.7, role emotional functioning 70.2 ± 36.0, mental health 73.2 ± 23.3 and bodily pain 80.9 ± 22.9. The mean EQ-VAS score > 4 years after TAVI was 64.7 ± 15.1. With respect to functional class, 80% of the patients were in NYHA class I/II at follow-up compared to 15% prior to TAVI. Conclusions This sub-study reports a significant improvement in functional class (NYHA) in a selected group of very elderly patients > 4 years after TAVI. Furthermore, all patients showed a satisfactory QoL despite their age and multiple comorbidities. In addition, our study reveals a lower QoL when compared with the general age matched Dutch population

    Differences in clinical valve size selection and valve size selection for patient-specific computer simulation in transcatheter aortic valve replacement (TAVR): a retrospective multicenter analysis

    Get PDF
    Valve size selection for transcatheter aortic valve replacement (TAVR) is currently based on cardiac CT-scan. At variance with patient-specific computer simulation, this does not allow the assessment of the valve-host interaction. We aimed to compare clinical valve size selection and valve size selection by an independent expert for computer simulation. A multicenter retrospective analysis of valve size selection by the physician and the independent expert in 141 patients who underwent TAVR with the self-expanding CoreValve or Evolut R. Baseline CT-scan was used for clinical valve size selection and for patient-specific computer simulation. Simulation results were not available for clinical use. Overall true concordance between clinical and simulated valve size selection was observed in 47 patients (33%), true discordance in 15 (11%) and ambiguity in 79 (56%). In 62 (44%, cohort A) one valve size was simulated whereas two valve sizes were simulated in 79 (56%, cohort B). In cohort A, concordance was 76% and discordance was 24%; a smaller valve size was selected for simulation in 10 patients and a larger in 5. In cohort B, a different valve size was selected for simulation in all patients in addition to the valve size that was used for TAVR. The different valve size concerned a smaller valve in 45 patients (57%) and a larger in 34 (43%). Selection of the valve size differs between the physician and the independent computer simulation expert who used the same source of information. These findings indicate that valve sizing in TAVR is still more intricate than generally assumed

    TAVI Care and Cure, the Rotterdam multidisciplinary program for patients undergoing transcatheter aortic valve implantation: Design and rationale

    Get PDF
    Background: The capacity of TAVI-programs and numbers of sites performing TAVI has rapidly increased. This necessitated the initiation of the Rotterdam TAVI Care & Cure Program, aiming to improve patient-centered care during the TAVI pathway. Methods: Consenting patients with severe aortic stenosis and an indication for TAVI will be included. The TAVI Care & Cure program will facilitate prognostic contributions to improve outcomes, patient satisfaction and quality of life in patients with valvular heart disease who are treated with a transcatheter aortic valve implantation in collaboration with the departments of cardiology, cardio-thoracic surgery, anesthesiology and geriatrics. Conclusion: With a single center observational registry, we aim to assess the TAVI patient clinical pathway, focusing on pre, peri and post interventional variables including functional status and HRQoL. We will evaluate the patient's complexity by applying an extended multidisciplinary approach, which includes a systematic application of geriatric assessments of frailty and cognitive function

    Impact of baseline and newly acquired conduction disorders on need for permanent pacemakers with 3 consecutive generations of self-expanding transcatheter aortic heart valves

    Get PDF
    Introductions: We aimed to compare conduction dynamics and need for permanent pacemaker implantation (PPI) after CoreValve, Evolut R and PRO (transcatheter aortic valve replacement (TAVR)). Methods: Patients were stratified based on conduction at baseline; Cohort A had normal conduction, Cohort B had conduction abnormalities including atrioventricular (AV)-block, fascicular block or complete bundle branch block. Three different dynamic QRS-patterns were defined: stable QRS-duration, transient QRS-prolongation and persistent QRS-prolongation. We performed multivariable regression analysis to estimate the effect of the three separate transcatheter heart valves (THV's) on need for PPI at 30 days. Results: TAVR was performed with CoreValve (N = 113), Evolut R (N = 157) or Evolut PRO (N = 92). Conduction dynamics were similar between the different THVs. Overall, Evolut R and PRO showed a tendency towards less PPI compared to CoreValve (17% vs. 19% vs. 27%, P = 0.08), which was driven by a lower PPI rate in Cohort A (6% vs. 11% vs. 25%, P = 0.002). Need for PPI was restricted to patients with persistent QRS-prolongation in Cohort A (26/106) but did not correlate with conduction dynamics in Cohort B. In multivariable logistic regression analysis the use of Evolut R (OR 0.38, 95% CI 0.19–0.78, P = 0.008) and PRO (OR 0.41, 95% CI 0.19–0.91, P-value = 0.028) were independently associated with less need for PPI. Conclusion: The newer generations Evolut R and PRO were associated with less PPI compared to CoreValve. Acquired persistent conduction abnormalities predicted PPI after TAVR only in patients with normal conduction at baseline. Our findings may help identify eligible patients for early discharge after Evolut R/PRO TAVR

    Expanding the indications for transcatheter aortic valve implantation

    No full text
    This Review discusses the evolving indications of transcatheter aortic valve implantation (TAVI), including the latest clinical trials in young and low-risk patients with symptomatic severe aortic stenosis and ongoing studies exploring TAVI for other indications, including severe bicuspid aortic valve stenosis and pure native aortic regurgitation, highlighting procedural implications and caveats of new and future indications.Transcatheter aortic valve implantation (TAVI) has revolutionized the treatment of symptomatic severe aortic valve stenosis. Current guidelines recommend TAVI in patients at increased operative risk of death. Advanced imaging planning, new transcatheter valve platforms, procedure streamlining and growing operator experience have improved procedural safety and bioprosthetic valve performance. As a result, TAVI has been explored for other indications. Two randomized trials published in 2019 to assess TAVI in patients with symptomatic severe aortic stenosis at low operative risk have set the stage for a new wave of indications. In younger and low-risk patients, TAVI had an early safety benefit over surgical aortic valve replacement and was associated with faster discharge from hospital and recovery and fewer rehospitalizations. In patients with symptomatic severe aortic stenosis, TAVI has now been explored across the entire spectrum of operative risk, from inoperable to low-risk populations, in properly designed, randomized clinical trials, although data on the long-term durability of these valves are lacking. The use of TAVI in severe bicuspid aortic valve stenosis, asymptomatic severe aortic stenosis, moderate aortic stenosis in combination with heart failure with reduced ejection fraction, and isolated pure aortic regurgitation is now under investigation in clinical trials. In this Review, we provide our perspective on these evolving indications for TAVI, discuss relevant available data from clinical trials, and highlight procedural implications and caveats of new and future indications.Cardiolog

    Reclassification of aortic stenosis by fusion of echocardiography and computed tomography in low-gradient aortic stenosis

    No full text
    Background The integration of computed tomography (CT)-derived left ventricular outflow tract area into the echocardiography-derived continuity equation results in the reclassification of a significant proportion of patients with severe aortic stenosis (AS) into moderate AS based on aortic valve area indexed to body surface area determined by fusion imaging (fusion AVA(i)). The aim of this study was to evaluate AS severity by a fusion imaging technique in patients with low-gradient AS and to compare the clinical impact of reclassified moderate AS versus severe AS. Methods We included 359 consecutive patients who underwent transcatheter aortic valve implantation for low-gradient, severe AS at two academic institutions and created a joint database. The primary endpoint was a composite of all-cause mortality and rehospitalisations for heart failure at 1 year. Results Overall, 35% of the population (n= 126) were reclassified to moderate AS [median fusion AVAi 0.70 (interquartile range, IQR 0.65-0.80)cm(2)/m(2)] and severe AS was retained as the classification in 65% [median fusion AVAi 0.49 (IQR 0.43-0.54) cm(2)/m(2)]. Lower body mass index, higher logistic EuroSCORE and larger aortic dimensions characterised patients reclassified to moderate AS. Overall, 57% of patients had a left ventricular ejection fraction (LVEF) = 50% (log-rankp= 0.029). Conclusions The integration of CT and transthoracic echocardiography to obtain fusion AVAi led to the reclassification of one third of patients with low-gradient AS to moderate AS. Reclassification did not affect clinical outcome, although patients reclassified to moderate AS with a LVEF <50% had worse outcomes owing to excess non-cardiac mortality.Cardiolog