    Comparação por análise visual entre as espículas promediadas e as espículas individuais nas descargas epileptiformes rolândicas

    Get PDF
    PURPOSE:This study compared some morphological features of individual rolandic epileptiform discharges, used to obtain an averaged estimate, with those of the resulting estimate. METHOD: Twenty-four averaged discharges from EEGs of 24 children showing rolandic spikes were compared with 480 individual discharges used in the averaging. The analysis was based on the occurrence of tangential dipole and double spike patterns. RESULTS: In 15 averaged discharges the tangential dipole pattern was found. Individual spikes used in the averaging process displayed the same pattern in 35-100% of them; in the remaining 9 averaged discharges, up to 20% of the individual spikes showed the same pattern, although this was not found in the averaged waveforms. Double spike pattern was found in 11 of the averaged waveforms and was recognized in 50-100% of its individual discharges, whereas up to 45% of individual spikes showed this pattern without expression in the averaged waveform. CONCLUSION: When visually analyzing an EEG with rolandic spikes, caution should be exercised in characterizing these patterns, since a few discharges showing them may not be expressed in the averaged waveform and the clinical correlations proposed for these patterns may not apply.OBJETIVO: Comparar as características morfológicas das descargas epileptiformes rolândicas individuais usadas para se obter uma descarga promediada com a resultante promediada. MÉTODO: Vinte e quatro descargas promediadas dos EEG de 24 crianças com descargas epileptiformes rolândicas foram comparadas com as 480 descargas individuais utilizadas na promediação. A análise foi baseada na ocorrência de dipolo tangencial e dupla espícula. RESULTADOS: Em 15 descargas promediadas o dipolo tangencial estava presente. As espículas individuais usadas na promediação mostraram o mesmo padrão em 35-100% das descargas. Nas 9 descargas promediadas restantes, até 20% das descargas individuais apresentavam o padrão, embora este não estivesse presente na resultante promediada. O padrão dupla espícula foi encontrado em 11 descargas promediadas, tendo sido reconhecido em 50-100% das descargas individuais, enquanto até 45% das espículas individuais mostraram este padrão sem que este estivesse presente na resultante promediada. CONCLUSÃO: Quando se procede à analise visual de um EEG com descargas epileptiformes rolândicas é necessário cuidado na caracterização desses padrões, pois algumas descargas podem apresentá-los sem manter a sua expressão na resultante promediada e as correlações clínicas referentes a esse padrões podem não se aplicar.UNIFESP-EPM Neurology and Neurosurgery DepartmentUNIFESP, EPM, Neurology and Neurosurgery DepartmentSciEL

    Uma breve nota histórica sobre a classificação das fibras nervosas

    Get PDF
    This is a brief review of the literature focused on the articles that formed the basis for the classification of the nerve fibers. Mention is also made to the origin of the nomenclature of the different motoneurons (a, b and g).Os autores fazem uma breve revisão da literatura com foco nos artigos que deram origem à classificação das fibras nervosas. É também mencionada no texto a origem da nomenclatura dos diferentes neurônios motores (a, b and g).Federal University of São Paulo Section on Research and Pos-graduation in Clinical NeurophysiologyUNIFESP, Section on Research and Pos-graduation in Clinical NeurophysiologySciEL

    Paresthesia and/or pain affecting the hand and/or wrist as a referral for electrodiagnostic studies

    Get PDF
    To study the reasons for referral to electrodiagnostic evaluation, 490 patients referred for electrodiagnostic evaluation to two laboratories (UNIFESP and UNEF) answered the following question: What was the reason that brought you to look for a physician and that led him to ask this examination? Paresthesia and/or pain were answered as the main reason by 175 of them (26% UNIFESP and 40% UNEF). The electromyographical examinations were normal in 30.8% and 35.3% and involvement of the median nerve at the wrist was detected in 5 9% and 51.5% of them. Nocturnal symptoms and paresthesia were commonly noted in both groups of patients; they, however, were not able to separate the patients with and without median nerve compression at the wrist. The question asked seems to be a useful selection instrument, to select two similar symptomatic samples of patients from two laboratories serving with very different target populations.Com o objetivo de conhecermos os motivos de encaminhamento para estudo eletrofisiológico, perguntamos a 490 pacientes, encaminhados a dois laboratórios de neurofisiologia (UNIFESP e UNEF): Qual o motivo que a(o) levou a procurar o médico e que fez com que ele solicitasse este exame? Parestesia e/ou dor nas mãos e/ou punhos foram espontaneamente referidas como motivo principal por 175 deles (26% UNIFESP e 40% UNEF). O exame eletroneuromiográfico foi normal em, respectivamente, 30,8% e 35,3% e revelou compressão do nervo mediano no carpo em 59% e 51,5% destes pacientes. Sintomas noturnos e parestesia foram comuns nos dois grupos de pacientes, mas não foram capazes de discriminar aqueles com e sem compressão do nervo mediano no carpo. O sintoma dor predominou nos pacientes com exame normal. A pergunta formulada pareceu ser bom instrumento de seleção. Conseguiu selecionar duas amostras de pacientes sintomáticos semelhantes, em laboratórios com população alvo muito diferente.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Setor de Neurofisiologia ClínicaUNIFESP, EPM, Setor de Neurofisiologia ClínicaSciEL

    Translation and validation of an instrument for evaluation of severity of symptoms and the functional status in carpal tunnel syndrome

    Get PDF
    The objective of the present study was to translate, to do cultural equivalence and validation of the Levine et al. (1993) or Boston Carpal Tunnel Questionnaire (BCTQ) to Portuguese. The BCTQ application to patients, selected by the question What was the reason that brought you to look for a physician and that led him to ask this examination? showed very good reproducibility. The validity was measured through the comparison of the severity symptoms scores (SSS) and the functional status scores (FSS) with the results of grip forces, Minnesota, two point discrimination, Semmes-Weinstein filaments perception and sensory conduction at the median nerve. The internal consistency was evaluated through Chronbach's alpha coefficient comparing the SSS and the FSS. The measuring properties were evaluated through paired t-test between pre and pos-surgical scores. Reproducibility, internal consistency, validation and measuring properties of the translated BCTQ were similar to those found by Levine et al. with the original version.Este estudo tem por objetivo traduzir, fazer a equivalência cultural e validar o questionário de Levine et al. (1993) ou Boston Carpal Tunnel Questionnaire (BCTQ), para o português. O BCTQ aplicado a pacientes selecionados pela pergunta Qual o motivo que a(o) levou a procurar o médico e que fez com que ele solicitasse este exame? mostrou boa reprodutibilidade. A validade foi medida comparando o escore de gravidade dos sintomas (EGS) e o escore do estado funcional (EEF) aos resultados dos testes de força de preensão e pinça, Minnesota, discriminação entre dois pontos, Semmes-Weinstein e velocidade de condução sensitiva no nervo mediano. A consistência interna foi avaliada pelo coeficiente a de Chronbach, comparando o EGS ao EEF. A propriedade de medida foi avaliada pelo teste t pareado, comparando escores pré-cirúrgicos aos pós-cirúrgicos. Reprodutibilidade, consistência interna, validade e propriedades de medida do BCTQ traduzido foram semelhantes às encontradas por Levine et al. na versão original.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de MedicinaUNIFESP, EPMSciEL

    Determination of electric current perception threshold in a sample of normal volunteers

    Get PDF
    Reference values using the instrument Neurometer® were determined and compared with those suggested by the manufacturer; the sensory thresholds for the different frequencies in different body segments were determined; the influence of age, level of education, gender and the reutilization of the electrodes in the different sites were also evaluated. Sensory threshold was determined in 101 normal volunteers (68 women), ages ranged from 17 to 87 years old. The procedure was fully automated with the sensory threshold being determined by the method of limits followed by the forced choice method. Analysis of the results revealed that: there was a significant difference between the values obtained for the index fingers and the halux; no difference was detected between both index fingers; gender and level of instruction had no effect on the results, age had a small influence after stimulation with 2000Hz and 250Hz; three reutilizations of the electrodes did not affect the results on the index fingers, however at the halux, the third utilization deteriorated the results from the 2000Hz stimulation. Except for the 2000Hz stimulation, significant differences were suggested between the values reported here and those provided by the manufacturer.Determinaram valores de referência para limiares de percepção de corrente elétrica senoidal em indivíduos normais, utilizando-se o instrumento Neurometer®; contrastaram-se os resultados com os fornecidos pelo fabricante; analisaram-se os limiares em diferentes segmentos corporais e avaliou-se o efeito da idade, sexo, grau de escolaridade e reutilização dos eletrodos. Estudou-se uma amostra de 101 voluntários normais (68 mulheres), com idades entre 17 e 87 anos. O procedimento foi completamente automatizado utilizando o método de límites e o de escolha forçada. Houve diferença significante entre os limiares obtidos no dedo indicador e no hálux nas três freqüências. Não houve diferenças significantes em relação ao sexo e grau de escolaridade; a idade apresentou discreta relação em algumas medidas. A reutilização dos eletrodos por três vezes nos dedos indicadores não comprometeu a confiabilidade, porém no hálux direito a reutilização por mais de duas vezes comprometeu a determinação do limiar para 2000Hz. Os valores obtidos diferiram das referências fornecidas pelo fabricante, nas freqüências 250Hz e 5Hz.Universidade Federal de São Paulo (UNIFESP) Setor de Neurofisiologia ClínicaUNIFESP, Setor de Neurofisiologia ClínicaSciEL

    Percepções e estimulações elétricas por correntes senoidais

    Get PDF
    OBJECTIVE: To analyze the relationship between perceptions and electrical senoidal current stimulation (ESCS). METHOD: The study population comprise 100 healthy volunteers. ESCS of 5 Hz and 2 kHz were applied to the left index finger at one and 1.5 sensory threshold. Following each stimulus train a list of eight words (four related to thin fiber sensations and four related to thick fiber sensations) was presented to the subjects who were asked to choose the three words closer to the experienced sensation. Each chosen word was given a score 1; final results were obtained by the sum of the scores for the words related to thin and thick fiber systems for each situation. RESULTS: For 5 Hz ESCS at one and 1.5 sensory threshold thin fibers had significantly higher scores than thick fibers; for 2 kHz ESCS, thick fibers had significantly higher scores. CONCLUSION: These results show that there is a relation between different sensations and ESCS of different frequencies.OBJETIVO: Estudar a relação entre as sensações evocadas por estimulação elétrica por corrente senoidal (ESCS). MÉTODO: 100 voluntários normais foram estudados. ESCS a 5 Hz e 2 kHz foram aplicadas no dedo indicador esquerdo com uma e 1,5 vezes o limiar sensorial. Listas de oito palavras (4 relacionadas a fibras grossas, 4 a fibras finas) foram apresentadas após cada estimulação e foi solicitado que o sujeito escolhesse as 3 palavras que mais se aproximassem das sensações experimentadas. Às palavras escolhidas foi dado o escore 1. Os resultados finais para análise foram obtidos da soma dos escores para as palavras relacionadas aos diferentes sistemas de fibras. RESULTADOS: Para ESCS a 5 Hz sensações relacionadas a fibras finas foram significantemente mais escolhidas, já para estimulações a 2 kHz sensações relacionadas a fibras grossas foram significantemente mais escolhidas. CONCLUSÃO: Estes resultados mostram um relação entre diferentes percepções e diferentes freqüências de correntes elétricas senoidais.City of São Paulo UniversityUNIFESP Neurology and Neurosurgery DepartmentFederal University of Minas Gerais Electrical Engineering DepartmentUNIFESP, Neurology and Neurosurgery DepartmentSciEL

    Rabdomiolise e mioglobinuria: relato de caso agudo com boa evolução

    No full text
    Os autores registram um caso de mioglobinúria confirmada pela eletroforese de proteínas da urina. A eletromiografia revelou alterações de tipo polimiosítico. A biópsia muscular do deltóide esquerdo mostrou processo inflamatório muscular inespecífico. O tratamento instituído baseou-se em repouso, hiperhidratação e alcalinização da urina. Os autores enfatizam a importância do diagnóstico pela relativa benignidade do processo, que tende para a cura se forem superadas as sérias complicações da fase aguda, a iatrogenia medicamentosa e por procedimentos diagnósticos desnecessários no início da doença.A case of paroxysmal myoglobinuric myopathy diagnosed by urinary protein electrophoresis is reported. Electromyograph (EMG) study done 20 days after onset of the symptoms demonstrated a polimyositic feature with normal motor and sensitive nervous conduction pattern. A biopsy of the left deltoid muscle performed 3 days after the EMG showed only an inespecific inflammation. The treatment included bed rest, parenteral fluids administration in excess (about 3,000 ml per day) and urinary alkalinization. Recovery started on the 2nd day of hospitalization when the patient showed progressive decrease in pain and weakness; furthermore the patient reacquired his mobility. The myoglobinuria start diminishing in intensity on the third day. The clinical picture of the patient continued to improve in the next 2 weeks, and slow recovery of the muscular strength occurred during the following two months of convalescence. In the present case we were not able to stablish the etiology of the illness. Nevertheless the clinical history suggests that infection, allergy and/or parenteral drug administration have had some role in precipitating the disease. This case report reinforces the concept that it is necessary an early and precise diagnosis of this syndrome followed by an adequate therapeutic approach avoiding the unnecessary use of drugs which per se could aggravate the disease