999 research outputs found

    Improving disclosure of medical error through educational program as a first step toward patient safety

    Get PDF
    Participant’s Response to medical errors. Description of data: Raw data of participant’s response to medical errors (3 clinical cases with different severity of error outcome), satisfaction and change after the education program. (XLSX 18 kb

    The Initial Extent of Malapposition in ST-Elevation Myocardial Infarction Treated with Drug-Eluting Stent: The Usefulness of Optical Coherence Tomography

    Get PDF
    PURPOSE: The aim of this study is to identify the extent of initial malapposition using optical coherence tomography (OCT) in ST-elevation myocardial infarctions (STEMI) treated with different types of drug-eluting stents (DES). MATERIALS AND METHODS: Twenty four STEMI patients that underwent primary percutaneous coronary intervention (PCI) were enrolled. The OCT and intravascular ultrasound (IVUS) were performed within 72 hours after the primary PCI. Distances between the endo-luminal surface of the strut reflection and the vessel wall and the extent of malapposition were measured and analyzed. RESULTS: Sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES) and zotarolimus-eluting stents (ZES) were deployed in 7 patients (29%), 7 patients (29%) and 10 patients (42%). In total, 4951 struts in 620 mm single-stent segments were analyzed (1463 struts in SES, 1522 in PES, and 1966 in ZES). In strut analysis by OCT, the incidence of malapposition was 17 % (860/4951) and in stent analysis by IVUS, malapposition rate was 21% (5/24). The malapposition rate of strut level using OCT in 5 patients who had malapposition in IVUS was significantly higher than the 19 of those who had not (32 +/- 5% vs. 12 +/- 6%, p = 0.001). In addition, the frequency of malapposition was also significantly different (28% in SES, 11% in PES, 10% in ZES, p = 0.001). The use of SES was an independent predictor of malapposed struts. CONCLUSION: The incidence of malapposition using OCT was quite prevalent in STEMI after primary PCI with DES implantation and SES has especially higher rates of malapposition compared to other DESs.ope

    Does Objective Structured Clinical Examinations Score Reflect the Clinical Reasoning Ability of Medical Students?

    Get PDF
    Abstract:BackgroundClinical reasoning ability is an important factor in a physician's competence and thus should be taught and tested in medical schools. Medical schools generally use objective structured clinical examinations (OSCE) to measure the clinical competency of medical students. However, it is unknown whether OSCE can also evaluate clinical reasoning ability. In this study, the authors investigated whether OSCE scores reflected students' clinical reasoning abilities.MethodsSixty-five fourth-year medical students participated in this study. Medical students completed the OSCE with 4 cases using standardized patients. For assessment of clinical reasoning, students were asked to list differential diagnoses and the findings that were compatible or not compatible with each diagnosis. The OSCE score (score of patient encounter), diagnostic accuracy score, clinical reasoning score, clinical knowledge score and grade point average (GPA) were obtained for each student, and correlation analysis was performed.ResultsClinical reasoning score was significantly correlated with diagnostic accuracy and GPA (correlation coefficient = 0.258 and 0.380; P = 0.038 and 0.002, respectively) but not with OSCE score or clinical knowledge score (correlation coefficient = 0.137 and 0.242; P = 0.276 and 0.052, respectively). Total OSCE score was not significantly correlated with clinical knowledge test score, clinical reasoning score, diagnostic accuracy score or GPA.ConclusionsOSCE score from patient encounters did not reflect the clinical reasoning abilities of the medical students in this study. The evaluation of medical students' clinical reasoning abilities through OSCE should be strengthened

    In-situ fabrication of cobalt-doped SrFe2As2 thin films by using pulsed laser deposition with excimer laser

    Full text link
    The remarkably high superconducting transition temperature and upper critical field of iron(Fe)-based layered superconductors, despite ferromagnetic material base, open the prospect for superconducting electronics. However, success in superconducting electronics has been limited because of difficulties in fabricating high-quality thin films. We report the growth of high-quality c-axis-oriented cobalt(Co)-doped SrFe2As2 thin films with bulk superconductivity by using an in-situ pulsed laser deposition technique with a 248-nm-wavelength KrF excimer laser and an arsenic(As)-rich phase target. The temperature and field dependences of the magnetization showing strong diamagnetism and transport critical current density with superior Jc-H performance are reported. These results provide necessary information for practical applications of Fe-based superconductors.Comment: 8 pages, 3figures. to be published at Appl. Phys. Let

    Beyond slurry-cast supercapacitor electrodes: PAN/MWNT heteromat-mediated ultrahigh capacitance electrode sheets

    Get PDF
    Supercapacitors (SCs) have garnered considerable attention as an appealing power source for forthcoming smart energy era. An ultimate challenge facing the SCs is the acquisition of higher energy density without impairing their other electrochemical properties. Herein, we demonstrate a new class of polyacrylonitrile (PAN)/multi-walled carbon tube (MWNT) heteromat-mediated ultrahigh capacitance electrode sheets as an unusual electrode architecture strategy to address the aforementioned issue. Vanadium pentoxide (V2O5) is chosen as a model electrode material to explore the feasibility of the suggested concept. The heteromat V2O5 electrode sheets are produced through one-pot fabrication based on concurrent electrospraying (for V2O5 precursor/MWNT) and electrospinning (for PAN nanofiber) followed by calcination, leading to compact packing of V2O5 materials in intimate contact with MWNTs and PAN nanofibers. As a consequence, the heteromat V2O5 electrode sheets offer three-dimensionally bicontinuous electron (arising from MWNT networks)/ion (from spatially reticulated interstitial voids to be filled with liquid electrolytes) conduction pathways, thereby facilitating redox reaction kinetics of V2O5 materials. In addition, elimination of heavy metallic foil current collectors, in combination with the dense packing of V2O5 materials, significantly increases (electrode sheet-based) specific capacitances far beyond those accessible with conventional slurry-cast electrodes.ope

    Clinical Study A Comparison of Clinical Outcomes of Dislocated Intraocular Lens Fixation between In Situ Refixation and Conventional Exchange Technique Combined with Vitrectomy

    Get PDF
    . Purpose. To evaluate surgical efficacy of in situ refixation technique for dislocated posterior chamber intraocular lens (PCIOL). Methods. This was a single-center retrospective case series. 34 patients (34 eyes) who underwent sclera fixation for dislocated IOLs combined with vitrectomy were studied. Of 34 eyes, 17 eyes underwent IOL exchange and the other 17 eyes underwent in situ refixation. Results. Mean follow-up period was 6 months. Mean logMAR best corrected visual acuity (BCVA) was not significantly different between the groups 6 months after surgery (0.10 ± 0.03 in the IOL exchange group and 0.10 ± 0.05 in the refixation group; = 0.065). Surgically induced astigmatism (SIA) was significantly lower in the refixation group (0.79 ± 0.41) than in the IOL exchange group (1.29 ± 0.46) ( = 0.004) at 3 months, which persisted to 6 months (1.13 ± 0.18 in the IOL exchange group and 0.74 ± 0.11 in the refixation group; = 0.006). Postoperative complications occurred in 3 eyes in the IOL exchange group (17.6%) and 2 eyes in the refixation group (11.8%). However, all of the patients were well managed without additional surgery. Conclusion. The in situ refixation technique should be preferentially considered if surgery is indicated since it seemed to produce a sustained less SIA compared to IOL exchange

    Percutaneous Cardiopulmonary Support in Refractory No-Reflow with Cardiogenic Shock after Coronary Stenting in Acute Myocardial Infarction

    Get PDF
    Coronary no-reflow is defined as inadequate myocardial perfusion of a given coronary segment without angiographic evidence of mechanical vessel obstruction. No-reflow is visualized angiographically as a reduction in thrombolysis in myocardial infarction (TIMI) flow grade and is typically accompanied by chest pain, electrocardiographic changes with ST-segment shift and possible hemodynamic compromise. No-reflow during primary percutaneous coronary intervention (PCI) results in increasing mortality and morbidity. Therefore, treatment of noreflow is associated with improved clinical outcomes. Generally, the treatment of no-reflow is based on pharmacotherapy. In this case, despite maximal pharmacotherapy and intraaortic balloon pump (IABP), refractory no-reflow accompanied with cardiogenic shock was successfully treated with percutaneous cardiopulmonary support (PCPS)

    Effect of 660 nm Light-Emitting Diode on the Wound Healing in Fibroblast-Like Cell Lines

    Get PDF
    Light in the red to near-infrared (NIR) range (630–1000 nm), which is generated using low energy laser or light-emitting diode (LED) arrays, was reported to have a range of beneficial biological effects in many injury models. NIR via a LED is a well-accepted therapeutic tool for the treatment of infected, ischemic, and hypoxic wounds as well as other soft tissue injuries in humans and animals. This study examined the effects of exposure to 660 nm red LED light at intensities of 2.5, 5.5, and 8.5 mW/cm2 for 5, 10, and 20 min on wound healing and proliferation in fibroblast-like cells, such as L929 mouse fibroblasts and human gingival fibroblasts (HGF-1). A photo illumination-cell culture system was designed to evaluate the cell proliferation and wound healing of fibroblast-like cells exposed to 600 nm LED light. The cell proliferation was evaluated by MTT assay, and a scratched wound assay was performed to assess the rate of migrating cells and the healing effect. Exposure to the 660 nm red LED resulted in an increase in cell proliferation and migration compared to the control, indicating its potential use as a phototherapeutic agent
    corecore