472 research outputs found

    Fructose transport-deficient Staphylococcus aureus reveals important role of epithelial glucose transporters in limiting sugar-driven bacterial growth in airway surface liquid.

    Get PDF
    Hyperglycaemia as a result of diabetes mellitus or acute illness is associated with increased susceptibility to respiratory infection with Staphylococcus aureus. Hyperglycaemia increases the concentration of glucose in airway surface liquid (ASL) and promotes the growth of S. aureus in vitro and in vivo. Whether elevation of other sugars in the blood, such as fructose, also results in increased concentrations in ASL is unknown and whether sugars in ASL are directly utilised by S. aureus for growth has not been investigated. We obtained mutant S. aureus JE2 strains with transposon disrupted sugar transport genes. NE768(fruA) exhibited restricted growth in 10 mM fructose. In H441 airway epithelial-bacterial co-culture, elevation of basolateral sugar concentration (5-20 mM) increased the apical growth of JE2. However, sugar-induced growth of NE768(fruA) was significantly less when basolateral fructose rather than glucose was elevated. This is the first experimental evidence to show that S. aureus directly utilises sugars present in the ASL for growth. Interestingly, JE2 growth was promoted less by glucose than fructose. Net transepithelial flux of D-glucose was lower than D-fructose. However, uptake of D-glucose was higher than D-fructose across both apical and basolateral membranes consistent with the presence of GLUT1/10 in the airway epithelium. Therefore, we propose that the preferential uptake of glucose (compared to fructose) limits its accumulation in ASL. Pre-treatment with metformin increased transepithelial resistance and reduced the sugar-dependent growth of S. aureus. Thus, epithelial paracellular permeability and glucose transport mechanisms are vital to maintain low glucose concentration in ASL and limit bacterial nutrient sources as a defence against infection

    Accuracy of popular automatic QT Interval algorithms assessed by a 'Gold Standard' and comparison with a Novel method: computer simulation study

    Get PDF
    BACKGROUND: Accurate measurement of the QT interval is very important from a clinical and pharmaceutical drug safety screening perspective. Expert manual measurement is both imprecise and imperfectly reproducible, yet it is used as the reference standard to assess the accuracy of current automatic computer algorithms, which thus produce reproducible but incorrect measurements of the QT interval. There is a scientific imperative to evaluate the most commonly used algorithms with an accurate and objective 'gold standard' and investigate novel automatic algorithms if the commonly used algorithms are found to be deficient. METHODS: This study uses a validated computer simulation of 8 different noise contaminated ECG waveforms (with known QT intervals of 461 and 495 ms), generated from a cell array using Luo-Rudy membrane kinetics and the Crank-Nicholson method, as a reference standard to assess the accuracy of commonly used QT measurement algorithms. Each ECG contaminated with 39 mixtures of noise at 3 levels of intensity was first filtered then subjected to three threshold methods (T1, T2, T3), two T wave slope methods (S1, S2) and a Novel method. The reproducibility and accuracy of each algorithm was compared for each ECG. RESULTS: The coefficient of variation for methods T1, T2, T3, S1, S2 and Novel were 0.36, 0.23, 1.9, 0.93, 0.92 and 0.62 respectively. For ECGs of real QT interval 461 ms the methods T1, T2, T3, S1, S2 and Novel calculated the mean QT intervals(standard deviations) to be 379.4(1.29), 368.5(0.8), 401.3(8.4), 358.9(4.8), 381.5(4.6) and 464(4.9) ms respectively. For ECGs of real QT interval 495 ms the methods T1, T2, T3, S1, S2 and Novel calculated the mean QT intervals(standard deviations) to be 396.9(1.7), 387.2(0.97), 424.9(8.7), 386.7(2.2), 396.8(2.8) and 493(0.97) ms respectively. These results showed significant differences between means at >95% confidence level. Shifting ECG baselines caused large errors of QT interval with T1 and T2 but no error with Novel. CONCLUSION: The algorithms T2, T1 and Novel gave low coefficients of variation for QT measurement. The Novel technique gave the most accurate measurement of QT interval, T3 (a differential threshold method) was the next most accurate by a large margin. The objective and accurate 'gold standard' presented in this paper may be useful to assess new QT measurement algorithms. The Novel algorithm may prove to be more accurate and reliable method to measure the QT interval

    Identificaçao da Via Lenta na Reentrada Nodal Atrioventricular Usando o Intervalo Atrioventricular Mais Curto

    Get PDF
    Em 10 pacientes consecutivos, realizou-se o mapeamento da parede septal do átrio direito durante taquicardia supraventricular por reentrada nodal AV, para comprovar a hipótese de que o intervalo AV mais curto identificava a área de conduçao da via lenta. O septo atrial foi dividido em quatro zonas distintas. Em sete dos pacientes o intervalo AV anterógrado mais curto foi encontrado na zona 3; em dois, na zona 4; no último, na zona 2. A modificaçao por radiofreqüência da via lenta foi obtida com sucesso, em todos os pacientes, na área de conduçao AV mais curta. O intervalo AV durante ritmo sinusal permaneceu inalterado antes e após a ablaçao. Após um seguimento de 21 ±4 meses, nenhum deles teve recorrência dos sintomas

    Identificaçao da Via Lenta na Reentrada Nodal Atrioventricular Usando o Intervalo Atrioventricular Mais Curto

    Get PDF
    Em 10 pacientes consecutivos, realizou-se o mapeamento da parede septal do átrio direito durante taquicardia supraventricular por reentrada nodal AV, para comprovar a hipótese de que o intervalo AV mais curto identificava a área de conduçao da via lenta. O septo atrial foi dividido em quatro zonas distintas. Em sete dos pacientes o intervalo AV anterógrado mais curto foi encontrado na zona 3; em dois, na zona 4; no último, na zona 2. A modificaçao por radiofreqüência da via lenta foi obtida com sucesso, em todos os pacientes, na área de conduçao AV mais curta. O intervalo AV durante ritmo sinusal permaneceu inalterado antes e após a ablaçao. Após um seguimento de 21 ±4 meses, nenhum deles teve recorrência dos sintomas

    Guidelines for autopsy investigation of sudden cardiac death: 2017 update from the Association for European Cardiovascular Pathology.

    Get PDF
    Although sudden cardiac death (SCD) is one of the most important modes of death in Western countries, pathologists and public health physicians have not given this problem the attention it deserves. New methods of preventing potentially fatal arrhythmias have been developed and the accurate diagnosis of the causes of SCD is now of particular importance. Pathologists are responsible for determining the precise cause and mechanism of sudden death but there is still considerable variation in the way in which they approach this increasingly complex task. The Association for European Cardiovascular Pathology has developed these guidelines, which represent the minimum standard that is required in the routine autopsy practice for the adequate investigation of SCD. The present version is an update of our original article, published 10 years ago. This is necessary because of our increased understanding of the genetics of cardiovascular diseases, the availability of new diagnostic methods, and the experience we have gained from the routine use of the original guidelines. The updated guidelines include a detailed protocol for the examination of the heart and recommendations for the selection of histological blocks and appropriate material for toxicology, microbiology, biochemistry, and molecular investigation. Our recommendations apply to university medical centers, regionals hospitals, and all healthcare professionals practicing pathology and forensic medicine. We believe that their adoption throughout Europe will improve the standards of autopsy practice, allow meaningful comparisons between different communities and regions, and permit the identification of emerging patterns of diseases causing SCD. Finally, we recommend the development of regional multidisciplinary networks of cardiologists, geneticists, and pathologists. Their role will be to facilitate the identification of index cases with a genetic basis, to screen appropriate family members, and ensure that appropriate preventive strategies are implemented

    Analytically Solvable Asymptotic Model of Atrial Excitability

    Get PDF
    We report a three-variable simplified model of excitation fronts in human atrial tissue. The model is derived by novel asymptotic techniques \new{from the biophysically realistic model of Courtemanche et al (1998) in extension of our previous similar models. An iterative analytical solution of the model is presented which is in excellent quantitative agreement with the realistic model. It opens new possibilities for analytical studies as well as for efficient numerical simulation of this and other cardiac models of similar structure

    Cost-effectiveness of In-home Automated External Defibrillators for Individuals at Increased Risk of Sudden Cardiac Death

    Full text link
    In-home automated external defibrillators (AEDs) are increasingly recommended as a means for improving survival of cardiac arrests that occur at home. The current study was conducted to explore the relationship between individuals' risk of cardiac arrest and cost-effectiveness of in-home AED deployment. Design : Markov decision model employing a societal perspective. Patients : Four hypothetical cohorts of American adults 60 years of age at progressively greater risk for sudden cardiac death (SCD): 1) all adults (annual probability of SCD 0.4%); 2) adults with multiple SCD risk factors (probability 2%); 3) adults with previous myocardial infarction (probability 4%); and 4) adults with ischemic cardiomyopathy unable to receive an implantable defibrillator (probability 6%). Intervention : Strategy 1: individuals suffering an in-home cardiac arrest were treated with emergency medical services equipped with AEDs (EMS-D). Strategy 2: individuals suffering an in-home cardiac arrest received initial treatment with an in-home AED, followed by EMS. Results : Assuming cardiac arrest survival rates of 15% with EMS-D and 30% with AEDs, the cost per quality-adjusted life-year gained (QALY) of providing in-home AEDs to all adults 60 years of age is 216,000.CostsofprovidinginhomeAEDstoadultswithmultipleriskfactors(2216,000. Costs of providing in-home AEDs to adults with multiple risk factors (2% probability of SCD), previous myocardial infarction (4% probability), and ischemic cardiomyopathy (6% probability) are 132,000, 104,000,and104,000, and 88,000, respectively. Conclusions : The cost-effectiveness of in-home AEDs is intimately linked to individuals' risk of SCD. However, providing in-home AEDs to all adults over age 60 appears relatively expensive.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/72168/1/j.1525-1497.2005.40247.x.pd

    Method for Quantitative Study of Airway Functional Microanatomy Using Micro-Optical Coherence Tomography

    Get PDF
    We demonstrate the use of a high resolution form of optical coherence tomography, termed micro-OCT (μOCT), for investigating the functional microanatomy of airway epithelia. μOCT captures several key parameters governing the function of the airway surface (airway surface liquid depth, periciliary liquid depth, ciliary function including beat frequency, and mucociliary transport rate) from the same series of images and without exogenous particles or labels, enabling non-invasive study of dynamic phenomena. Additionally, the high resolution of μOCT reveals distinguishable phases of the ciliary stroke pattern and glandular extrusion. Images and functional measurements from primary human bronchial epithelial cell cultures and excised tissue are presented and compared with measurements using existing gold standard methods. Active secretion from mucus glands in tissue, a key parameter of epithelial function, was also observed and quantified
    corecore