186 research outputs found

    Improving angle stability by switching shunt reactors in mixed overhead cable lines. An Italian 400 kV case study

    Get PDF
    Stringent environmental constraints make the construction of new transmission overhead lines more and more difficult. Alternatively, today it is possible to use cable lines for high (HV) and extra-high (EHV) voltage systems. The configuration of the so-called mixed lines can create some problems in the operation of the electrical system, both during steady-state and transient conditions. In particular, the system stability is one of the main concerns when analyzing the dynamic response of power systems. In this paper, the study of angular stability of a system containing a mixed line is presented: a specific control logic applied to the shunt reactors of the mixed line is proposed as improvement of the overall system stability. The proposed switching logic is first discussed from a theoretical point of view and validated with two different testing systems. Then, the existing overhead-cable lines connecting Sicily to the rest of continental Europe 400 kV power system are taken as case study for the application of the proposed switching strategy. Several simulations are performed in the power system analysis software NEPLAN360: the results show the fundamental role of the timing of the control actions applied on the shunt reactors in helping the system to keep the stability. The proposed control proves to be an effective support to the system subjected to critical contingencies, contributing decisively to avoid the angular separation between areas and therefore to preserve the stability of the system

    Analysis and simulations of the primary frequency control during a system split in continental europe power system

    Get PDF
    The occurrence of system separations in the power system of Continental Europe has been observed in recent decades as a critical event which might cause power imbalances higher than the reference incident specified per system design, representing an actual challenge for the stability and safe operation of the system. This work presents an analysis and simulations of the primary frequency control in the Continental Europe synchronous area in conditions of system separation. The adopted approach is based on fundamental aspects of the frequency-containment reserve process. The analysis takes an actual event into consideration, which determined the separation of the system in January 2021. The main purpose of the work is the development of specific models and simulations able to reproduce the actual split event. Due to specific arrangements discussed in detail, it is possible to obtain a substantial match between the simulations and the frequencies registered after the system split. The work also provides insight into the importance of the temporal sequence of power imbalances and defensive actions in the primary frequency control process. The models developed in the work are finally used to investigate the separation event under different operating conditions, such as missing defensive actions and low inertia scenarios

    An original control strategy of storage systems for the frequency stability of autonomous grids with renewable power generation

    Get PDF
    This work examines the operation of the autonomous power system of a geographical island assuming the integration of significant generation shares from renewable energy sources and the installation of the required storage systems. The frequency stability of the system is investigated considering different operating conditions, in terms of load demand and renewable power generation. The main focus of the work is an original control strategy specifically designed for power converters interfacing storage units to the grid. The proposed strategy is based on an extended frequency droop control, which selects specific droop settings depending on the operating mode—charge or discharge—of the storage unit. A simulation model of the whole electrical system is developed for dynamic analysis. The model also implements the possibility of including specific auxiliary frequency controls for synthetic inertia and primary reserve. The results of the simulation and analysis indicate that the proposed control strategy has a significant positive effect, making the storage units able to provide a fundamental and more effective support to the frequency stability of the system. The application of the proposed control strategy to storage units also reduces the need for a contribution to the frequency control from intermittent and variable sources, making the whole system more robust, stable and reliable

    Frequency Dynamics in Fully Non-Synchronous Electrical Grids: A Case Study of an Existing Island

    Get PDF
    The operation of a power system with 100% converter-interfaced generation poses several questions and challenges regarding various aspects of the design and the control of the system. Existing literature on the integration of renewable energy sources in isolated systems mainly focuses on energy aspects or steady-state issues, and only a few studies examine the dynamic issues of autonomous networks operated with fully non-synchronous generation. A lack of research can be found in particular in the determination of the required amount of grid-forming power, the selection of the number and rated power of the units which should implement the grid-forming controls, and the relative locations of the grid-forming converters. The paper aims to address those research gaps starting from a theoretical point of view and then by examining the actual electrical network of an existing island as a case study. The results obtained from the investigations indicate specific observations and design opportunities, which are essential for securing the synchronization and the stability of the grid. Possible solutions for a fully non-synchronous operation of autonomous systems, in terms of dynamic characteristics and frequency stability, are presented and discussed

    A General Methodology for Short-circuit Calculations in Hybrid AC/DC Microgrids

    Get PDF
    In this paper, the issues related to short-circuit calculations in hybrid AC/DC microgrids are discussed. The reference standard for short-current calculations in DC systems is the IEC 61660, which provides a mathematical formulation of the problem. The standard only includes radial DC grids and does not consider a more complex system, such as meshed DC systems or a hybrid AC/DC microgrid. This paper proposes a generalized approach that can be used independently of the characteristics of the hybrid system. The proposed approach is applied to four test microgrids with different distributed sources and number of nodes and the results are compared with those obtained simulating the same grids with Neplan 360®

    New hope in brain glioma surgery: The role of intraoperative ultrasound. A review

    Get PDF
    Maximal safe resection represents the gold standard for surgery of malignant brain tumors. As regards gross-total resection, accurate localization and precise delineation of the tumor margins are required. Intraoperative diagnostic imaging (Intra-Operative Magnetic Resonance-IOMR, Intra-Operative Computed Tomography-IOCT, Intra-Operative Ultrasound-IOUS) and dyes (fluorescence) have become relevant in brain tumor surgery, allowing for a more radical and safer tumor resection. IOUS guidance for brain tumor surgery is accurate in distinguishing tumor from normal parenchyma, and it allows a real-time intraoperative visualization. We aim to evaluate the role of IOUS in gliomas surgery and to outline specific strategies to maximize its efficacy. We performed a literature research through the Pubmed database by selecting each article which was focused on the use of IOUS in brain tumor surgery, and in particular in glioma surgery, published in the last 15 years (from 2003 to 2018). We selected 39 papers concerning the use of IOUS in brain tumor surgery, including gliomas. IOUS exerts a notable attraction due to its low cost, minimal interruption of the operational flow, and lack of radiation exposure. Our literature review shows that increasing the use of ultrasound in brain tumors allows more radical resections, thus giving rise to increases in survival

    Critical Assessments of the Potential for Integrating Renewable Energy into Isolated Grids on Vietnamese Islands: The Case of the An-Binh Grid

    Get PDF
    Renewable electricity for off-grid areas is widely seen as one of the top choices in supporting local economic development in most countries, and so is Vietnam. Over the years, many isolated networks using renewable energy sources have been deployed for off-grid areas in Vietnam. However, the use of these energy sources in Vietnam’s isolated networks is still facing many challenges due to its infancy here. The issues of reliability and vulnerability of these networks are not given the expected attention. Another challenge is that the issues of the operational security of these systems could also be negatively affected by the variable nature of renewable sources, including static and dynamic security. For this reason, this study aims to contribute to a better understanding of integrating renewable energy into isolated networks, and in this case, using solar power for the An-Binh Island grid in Vietnam. The findings from this study suggest that choosing the right structure of the power mix could contribute to improving the operational security of isolated networks. Moreover, several solutions to enhance the reliability of this grid are also proposed. The NEPLAN environment was selected for simulation and analysis for all the scenarios in this study

    Factors affecting adherence to guidelines for antithrombotic therapy in elderly patients with atrial fibrillation admitted to internal medicine wards

    Get PDF
    Current guidelines for ischemic stroke prevention in atrial fibrillation or flutter (AFF) recommend Vitamin K antagonists (VKAs) for patients at high-intermediate risk and aspirin for those at intermediate-low risk. The cost-effectiveness of these treatments was demonstrated also in elderly patients. However, there are several reports that emphasize the underuse of pharmacological prophylaxis of cardio-embolism in patients with AFF in different health care settings. AIMS: To evaluate the adherence to current guidelines on cardio-embolic prophylaxis in elderly (> 65 years old) patients admitted with an established diagnosis of AFF to the Italian internal medicine wards participating in REPOSI registry, a project on polypathologies/polytherapies stemming from the collaboration between the Italian Society of Internal Medicine and the Mario Negri Institute of Pharmacological Research; to investigate whether or not hospitalization had an impact on guidelines adherence; to test the role of possible modifiers of VKAs prescription. METHODS: We retrospectively analyzed registry data collected from January to December 2008 and assessed the prevalence of patients with AFF at admission and the prevalence of risk factors for cardio-embolism. After stratifying the patients according to their CHADS(2) score the percentage of appropriateness of antithrombotic therapy prescription was evaluated both at admission and at discharge. Univariable and multivariable logistic regression models were employed to verify whether or not socio-demographic (age >80years, living alone) and clinical features (previous or recent bleeding, cranio-facial trauma, cancer, dementia) modified the frequency and modalities of antithrombotic drugs prescription at admission and discharge. RESULTS: Among the 1332 REPOSI patients, 247 were admitted with AFF. At admission, CHADS(2) score was ≥ 2 in 68.4% of patients, at discharge in 75.9%. Among patients with AFF 26.5% at admission and 32.8% at discharge were not on any antithrombotic therapy, and 43.7% at admission and 40.9% at discharge were not taking an appropriate therapy according to the CHADS(2) score. The higher the level of cardio-embolic risk the higher was the percentage of antiplatelet- but not of VKAs-treated patients. At admission or at discharge, both at univariable and at multivariable logistic regression, only an age >80 years and a diagnosis of cancer, previous or active, had a statistically significant negative effect on VKAs prescription. Moreover, only a positive history of bleeding events (past or present) was independently associated to no VKA prescription at discharge in patients who were on VKA therapy at admission. If heparin was considered as an appropriate therapy for patients with indication for VKAs, the percentage of patients admitted or discharged on appropriate therapy became respectively 43.7% and 53.4%. CONCLUSION: Among elderly patients admitted with a diagnosis of AFF to internal medicine wards, an appropriate antithrombotic prophylaxis was taken by less than 50%, with an underuse of VKAs prescription independently of the level of cardio-embolic risk. Hospitalization did not improve the adherence to guideline

    Adherence to antibiotic treatment guidelines and outcomes in the hospitalized elderly with different types of pneumonia

    Get PDF
    Background: Few studies evaluated the clinical outcomes of Community Acquired Pneumonia (CAP), Hospital-Acquired Pneumonia (HAP) and Health Care-Associated Pneumonia (HCAP) in relation to the adherence of antibiotic treatment to the guidelines of the Infectious Diseases Society of America (IDSA) and the American Thoracic Society (ATS) in hospitalized elderly people (65 years or older). Methods: Data were obtained from REPOSI, a prospective registry held in 87 Italian internal medicine and geriatric wards. Patients with a diagnosis of pneumonia (ICD-9 480-487) or prescribed with an antibiotic for pneumonia as indication were selected. The empirical antibiotic regimen was defined to be adherent to guidelines if concordant with the treatment regimens recommended by IDSA/ATS for CAP, HAP, and HCAP. Outcomes were assessed by logistic regression models. Results: A diagnosis of pneumonia was made in 317 patients. Only 38.8% of them received an empirical antibiotic regimen that was adherent to guidelines. However, no significant association was found between adherence to guidelines and outcomes. Having HAP, older age, and higher CIRS severity index were the main factors associated with in-hospital mortality. Conclusions: The adherence to antibiotic treatment guidelines was poor, particularly for HAP and HCAP, suggesting the need for more adherence to the optimal management of antibiotics in the elderly with pneumonia
    • …
    corecore