    Improving angle stability by switching shunt reactors in mixed overhead cable lines. An Italian 400 kV case study

    Get PDF
    Stringent environmental constraints make the construction of new transmission overhead lines more and more difficult. Alternatively, today it is possible to use cable lines for high (HV) and extra-high (EHV) voltage systems. The configuration of the so-called mixed lines can create some problems in the operation of the electrical system, both during steady-state and transient conditions. In particular, the system stability is one of the main concerns when analyzing the dynamic response of power systems. In this paper, the study of angular stability of a system containing a mixed line is presented: a specific control logic applied to the shunt reactors of the mixed line is proposed as improvement of the overall system stability. The proposed switching logic is first discussed from a theoretical point of view and validated with two different testing systems. Then, the existing overhead-cable lines connecting Sicily to the rest of continental Europe 400 kV power system are taken as case study for the application of the proposed switching strategy. Several simulations are performed in the power system analysis software NEPLAN360: the results show the fundamental role of the timing of the control actions applied on the shunt reactors in helping the system to keep the stability. The proposed control proves to be an effective support to the system subjected to critical contingencies, contributing decisively to avoid the angular separation between areas and therefore to preserve the stability of the system

    Analysis and simulations of the primary frequency control during a system split in continental europe power system

    Get PDF
    The occurrence of system separations in the power system of Continental Europe has been observed in recent decades as a critical event which might cause power imbalances higher than the reference incident specified per system design, representing an actual challenge for the stability and safe operation of the system. This work presents an analysis and simulations of the primary frequency control in the Continental Europe synchronous area in conditions of system separation. The adopted approach is based on fundamental aspects of the frequency-containment reserve process. The analysis takes an actual event into consideration, which determined the separation of the system in January 2021. The main purpose of the work is the development of specific models and simulations able to reproduce the actual split event. Due to specific arrangements discussed in detail, it is possible to obtain a substantial match between the simulations and the frequencies registered after the system split. The work also provides insight into the importance of the temporal sequence of power imbalances and defensive actions in the primary frequency control process. The models developed in the work are finally used to investigate the separation event under different operating conditions, such as missing defensive actions and low inertia scenarios

    An original control strategy of storage systems for the frequency stability of autonomous grids with renewable power generation

    Get PDF
    This work examines the operation of the autonomous power system of a geographical island assuming the integration of significant generation shares from renewable energy sources and the installation of the required storage systems. The frequency stability of the system is investigated considering different operating conditions, in terms of load demand and renewable power generation. The main focus of the work is an original control strategy specifically designed for power converters interfacing storage units to the grid. The proposed strategy is based on an extended frequency droop control, which selects specific droop settings depending on the operating mode—charge or discharge—of the storage unit. A simulation model of the whole electrical system is developed for dynamic analysis. The model also implements the possibility of including specific auxiliary frequency controls for synthetic inertia and primary reserve. The results of the simulation and analysis indicate that the proposed control strategy has a significant positive effect, making the storage units able to provide a fundamental and more effective support to the frequency stability of the system. The application of the proposed control strategy to storage units also reduces the need for a contribution to the frequency control from intermittent and variable sources, making the whole system more robust, stable and reliable

    Frequency Dynamics in Fully Non-Synchronous Electrical Grids: A Case Study of an Existing Island

    Get PDF
    The operation of a power system with 100% converter-interfaced generation poses several questions and challenges regarding various aspects of the design and the control of the system. Existing literature on the integration of renewable energy sources in isolated systems mainly focuses on energy aspects or steady-state issues, and only a few studies examine the dynamic issues of autonomous networks operated with fully non-synchronous generation. A lack of research can be found in particular in the determination of the required amount of grid-forming power, the selection of the number and rated power of the units which should implement the grid-forming controls, and the relative locations of the grid-forming converters. The paper aims to address those research gaps starting from a theoretical point of view and then by examining the actual electrical network of an existing island as a case study. The results obtained from the investigations indicate specific observations and design opportunities, which are essential for securing the synchronization and the stability of the grid. Possible solutions for a fully non-synchronous operation of autonomous systems, in terms of dynamic characteristics and frequency stability, are presented and discussed

    A General Methodology for Short-circuit Calculations in Hybrid AC/DC Microgrids

    Get PDF
    In this paper, the issues related to short-circuit calculations in hybrid AC/DC microgrids are discussed. The reference standard for short-current calculations in DC systems is the IEC 61660, which provides a mathematical formulation of the problem. The standard only includes radial DC grids and does not consider a more complex system, such as meshed DC systems or a hybrid AC/DC microgrid. This paper proposes a generalized approach that can be used independently of the characteristics of the hybrid system. The proposed approach is applied to four test microgrids with different distributed sources and number of nodes and the results are compared with those obtained simulating the same grids with Neplan 360®

    Evaluation Of Elastic Modulus And Stress Gradient Of PECVD Silicon Nitride Thin Films

    Get PDF
    This study investigated the techniques for determining the elastic modulus and estimating the stress gradient of plasma-enhanced chemical vapor deposition (PECVD) silicon nitride thin films. The experimentally determined elastic modulus was then used in a finite element beam model to compute the stress distribution inside the thin films using a commercial finite element analysis package. The computed beam displacement caused by a given stress gradient was compared with the displacement experimentally evaluated using optical interference microscopy. This comparison allows the stress gradient of the PECVD silicon nitride membrane introduced by the fabrication process to be evaluated

    Critical Assessments of the Potential for Integrating Renewable Energy into Isolated Grids on Vietnamese Islands: The Case of the An-Binh Grid

    Get PDF
    Renewable electricity for off-grid areas is widely seen as one of the top choices in supporting local economic development in most countries, and so is Vietnam. Over the years, many isolated networks using renewable energy sources have been deployed for off-grid areas in Vietnam. However, the use of these energy sources in Vietnam’s isolated networks is still facing many challenges due to its infancy here. The issues of reliability and vulnerability of these networks are not given the expected attention. Another challenge is that the issues of the operational security of these systems could also be negatively affected by the variable nature of renewable sources, including static and dynamic security. For this reason, this study aims to contribute to a better understanding of integrating renewable energy into isolated networks, and in this case, using solar power for the An-Binh Island grid in Vietnam. The findings from this study suggest that choosing the right structure of the power mix could contribute to improving the operational security of isolated networks. Moreover, several solutions to enhance the reliability of this grid are also proposed. The NEPLAN environment was selected for simulation and analysis for all the scenarios in this study

    Right ventricular function in AL amyloidosis: characteristics and prognostic implication

    Get PDF
    AIM: The importance of right ventricle (RV) dysfunction in AL amyloidosis has been underestimated. This study was designed to comprehensively evaluate RV function and its prognostic role in patients with AL amyloidosis with and without echocardiographic evidence of cardiac involvement. METHOD AND RESULTS: Fifty-two biopsy-proven AL amyloidosis patients underwent a thorough echocardiographic evaluation. Twenty-seven patients (CA) met the international echocardiographic criteria for cardiac involvement [left ventricular (LV) wall thickness >/= 12 mm] and 25 patients had no cardiac amyloidosis features (NCA). Patients were compared with a sex- age-matched control group. Patients and controls underwent traditional, tissue Doppler (TDI), speckle-tracking left and RV echocardiographic evaluation. No difference was observed between groups in RV diastolic diameter, whereas CA patients showed increased RV free wall thickness (P< 0.0001). Compared with controls and NCA patients, traditional echocardiography, TDI, and speckle-tracking evaluation detected significantly (P< 0.0001) depressed RV longitudinal systolic function in CA patients. No difference was observed between groups at Doppler diastolic evaluation, whereas at tricuspidal annulus TDI analysis, CA subject showed significantly lower E' and A' values with increased E/E' ratio (P< 0.0001). Over a 19 months median follow-up period, 18 patients died. Cox multivariate analysis showed that N-terminal pro-Brain natriuretic peptide and RV longitudinal strain were the strongest death predictor. CONCLUSION: Our data show that in patients with AL amyloidosis, RV involvement develops later than LV amyloid deposition but when it occurs, prognosis dramatically worsens. Moreover RV longitudinal strain was the only echocardiographic predictor of prognosis. We suggest that RV function analysis should be performed routinely as a part of echocardiographic evaluation in these patients

    Oral hyposensitization to nickel induces clinical improvement and a decrease in TH1 and TH2 cytokines in patients with systemic nickel allergy syndrome.

    Get PDF
    Some patients with nickel (Ni) allergic contact dermatitis suffer from systemic (intestinal or cutaneous) symptoms after ingestion of Ni-rich foods and experience symptoms reduction with low-Ni diet, a condition termed "systemic Ni allergy syndrome" (SNAS). We aimed at evaluating whether oral administration of low nickel doses improved clinical conditions and modulated immunological aspects of SNAS, without significant side effects. Thirty-six SNAS patients were enrolled. Treatment started after 1-month of low-Ni diet and consisted in an incremental oral NiOH dose phase (0.3ng to 1.5 μg/week) followed by a 12-months maintenance phase (1.5 μg/week). Randomly, twenty-four patients added Ni therapy to low-Ni diet and 12 remained with diet alone. All patients were allowed rescue medications (antihistamines and topical steroids). After 4 months, Ni-rich foods were gradually reintroduced. In vitro allergen-driven IL13, IL5 and IFNγ release by peripheral blood mononuclear cells was evaluated before and after treatment. Twenty-three patients receiving NiOH and the 12 control patients completed the study. Evaluation of SNAS clinical severity (by VAS and drug consumption) showed a significant difference in favor of NiOH-treated patients compared to controls. Twenty of 23 patients in the NiOH group and none in the control group tolerated Ni-rich food reintroduction. Release of all studied cytokines in culture supernatants was significantly lower after NiOH treatment. In conclusion NiOH is effective in reducing symptoms and drug consumption in SNAS and is able to modulate inflammatory parameters

    New hope in brain glioma surgery: The role of intraoperative ultrasound. A review

    Get PDF
    Maximal safe resection represents the gold standard for surgery of malignant brain tumors. As regards gross-total resection, accurate localization and precise delineation of the tumor margins are required. Intraoperative diagnostic imaging (Intra-Operative Magnetic Resonance-IOMR, Intra-Operative Computed Tomography-IOCT, Intra-Operative Ultrasound-IOUS) and dyes (fluorescence) have become relevant in brain tumor surgery, allowing for a more radical and safer tumor resection. IOUS guidance for brain tumor surgery is accurate in distinguishing tumor from normal parenchyma, and it allows a real-time intraoperative visualization. We aim to evaluate the role of IOUS in gliomas surgery and to outline specific strategies to maximize its efficacy. We performed a literature research through the Pubmed database by selecting each article which was focused on the use of IOUS in brain tumor surgery, and in particular in glioma surgery, published in the last 15 years (from 2003 to 2018). We selected 39 papers concerning the use of IOUS in brain tumor surgery, including gliomas. IOUS exerts a notable attraction due to its low cost, minimal interruption of the operational flow, and lack of radiation exposure. Our literature review shows that increasing the use of ultrasound in brain tumors allows more radical resections, thus giving rise to increases in survival
    • …
    corecore