162 research outputs found

    Social media for cardiac imagers: a review.

    Get PDF
    Cardiac imaging plays a pivotal role in the diagnosis and management of cardiovascular diseases. In the burgeoning landscape of digital technology and social media platforms, it becomes essential for cardiac imagers to know how to effectively increase the visibility and the impact of their activity. With the availability of social sites like X (formerly Twitter), Instagram and Facebook, cardiac imagers can now reach a wider audience and engage with peers, sharing their findings, insights, and discussions. The integration of persistent identifiers, such as Digital Object Identifiers (DOIs), facilitates traceability and citation of cardiac imaging publications across various digital platforms, further enhancing their discoverability. To maximize visibility, practical advice is provided, including the use of visually engaging infographics and videos, as well as the strategic implementation of relevant hashtags and keywords. These techniques can significantly improve the discoverability of cardiac imaging research through search engine optimization and social media algorithms. Tracking impact and engagement is crucial in the digital age, and this review discusses various metrics and tools to gauge the reach and influence of cardiac imaging publications. This includes traditional citation-based metrics and altmetrics. Moreover, this review underscores the importance of creating and updating professional profiles on social platforms and participating in relevant scientific communities online. The adoption of digital technology, social platforms, and a strategic approach to publication sharing can empower cardiac imaging professionals to enhance the visibility and impact of their research, ultimately advancing the field and improving patient care

    RESEARCHES ON THE INFLUENCE OF RISKS IN INDUSTRIAL ORGANIZATIONS’ PROCESSES WHEN IMPLEMENTING QUALITY-RISK INTEGRATED MANAGEMENT SYSTEMS

    Get PDF
    The concept of the integrated quality-risk management system can be defined as a set of methodologies, associated processes that invariably use human resources, material and financial resources, equipments and knowledge, in order to meet the objectives aimed at satisfying all interested parties.In the conditions of fulfilling the integrated management system, it will bring many economic and financial benefits in order to reduce the consumption of resources and increase the profit. If implemented correctly, the quality-risk integrated management system will include all business competencies in a systematic environment that will deliver on the mission of the organization, contribute to increasing benefits, optimize resource consumption, and reduce costs to maintain multiple integrated management systems

    An atypical case of pulmonary embolism from a jugular vein

    Get PDF
    Neck venous malformations and their potentially life-threatening complications are rarely reported in the available literature. Cases of aneurysmal or hypo-plastic jugular vein thrombosis associated with systemic embolization have not been frequently reported. We present the case of a 60-year-old male, without any known risk factors for thromboembolic disease, admitted for sudden onset dyspnea. The physical examination was remarkable for a right lateral cervical mass, expanding with Valsalva maneuver. Thoracic CT with contrast established the diagnosis of bilateral pulmonary embolism and raised the suspicion of superior vena cava and right atrial thrombosis. Bedside transthoracic echocardiography confirmed the presence of a large right atrial thrombus, with intermittent protrusion through the tricuspid valve. Systemic thrombolysis with Alteplase was initiated shortly after diagnosis, in parallel with unfractionated heparin, with complete resolution of the intracavitary thrombus documented by echocardiography. The patient showed significant improvement in symptoms and was later started on oral anticoagulation. Computed vascular tomography of the neck was performed before discharge, showing hypoplasia of the left internal jugular vein and aneurismal dilation of the contralateral internal jugular vein, without thrombosis. There were no identifiable systemic causes for thrombosis. Surgical resection of the aneurismal jugular vein was excluded, because of its potential to cause intracranial hypertension. The preferred therapeutic option in this case was long-term oral anticoagulation

    Evaluation of Left Atrial Size and Function: Relevance for Clinical Practice

    Get PDF
    Left atrial (LA) structural and functional evaluation have recently emerged as powerful biomarkers for adverse events in a variety of cardiovascular conditions. Moreover, noninvasive evaluation of LA pressure has gained importance in the characterization of the hemodynamic profile of patients. This review describes the methodology, benefits and pitfalls of measuring LA size and function by echocardiography and provides a brief overview of the prognostic utility of newer echocardiographic metrics of LA geometry and function (i.e., three-dimensional volumes, longitudinal strain, and phasic function parameters)

    Higher ventricular-arterial coupling derived from three-dimensional echocardiography is associated with a worse clinical outcome in systemic sclerosis

    Get PDF
    Primary myocardial involvement is common in systemic sclerosis (SSc). Ventricular-arterial coupling (VAC) reflecting the interplay between ventricular performance and arterial load, is a key determinant of cardiovascular (CV) performance. We aimed to investigate VAC, VAC-derived indices, and the potential association between altered VAC and survival free from death/hospitalization for major adverse CV events (MACE) in scleroderma. Only SSc patients without any anamnes-tic and echocardiographic evidence of primary myocardial involvement who underwent three-dimensional echocardiography (3DE) were included in this cross-sectional study and compared with healthy matched controls. 3DE was used for noninvasive measurements of end-systolic elastance (Ees), arterial elastance (Ea), VAC (Ea/Ees) and end-diastolic elastance (Eed); the occurrence of death/hospitalization for MACE was recorded during follow-up. Sixty-five SSc patients (54 female; aged 56 ± 14 years) were included. Ees (p = 0.04), Ea (p = 0.04) and Eed (p = 0.01) were higher in patients vs. controls. Thus, VAC was similar in both groups. Ees was lower and VAC was higher in patients with diffuse cutaneous form (dcSSc) vs. patients with limited form (lcSSc) (p = 0.001 and p = 0.02, respectively). Over a median follow-up of 4 years, four patients died for heart failure and 34 were hospitalized for CV events. In patients with VAC >0.63 the risk of MACE was higher (HR 2.5; 95% CI 1.13–5.7; p = 0.01) and survival free from death/hospitalization was lower (p = 0.005) than in those with VAC < 0.63. Our study suggests that VAC may be impaired in SSc patients without signs and symptoms of primary myocardial involvement. Moreover, VAC appears to have a prognostic role in SSc

    EACVI survey on radiation exposure in interventional echocardiography.

    Get PDF
    AIMS: The European Association of Cardiovascular Imaging (EACVI) Scientific Initiatives Committee performed a global survey on radiation exposure in interventional echocardiography. The survey aimed to collect data on local practices for radioprotection in interventional echocardiography and to assess the awareness of echocardiography operators about radiation-related risks. METHODS AND RESULTS: A total of 258 interventional echocardiographers from 52 different countries (48% European) responded to the survey. One hundred twenty-two (47%) participants were women. Two-thirds (76%) of interventional echocardiographers worked in tertiary care/university hospitals. Interventional echocardiography was the main clinical activity for 34% of the survey participants. The median time spent in the cath-lab for the echocardiographic monitoring of structural heart procedures was 10 (5-20) hours/month. Despite this, only 28% of interventional echocardiographers received periodic training and certification in radioprotection and 72% of them did not know their annual radiation dose. The main adopted personal protection devices were lead aprons and thyroid collars (95% and 92% of use, respectively). Dedicated architectural protective shielding was not available for 33% of interventional echocardiographers. Nearly two-thirds of responders thought that the radiation exposure of interventional echocardiographers was higher than that of interventional cardiologists and 72% claimed for an improvement in the radioprotection measures. CONCLUSION: Radioprotection measures for interventional echocardiographers are widely variable across centres. Radioprotection devices are often underused by interventional echocardiographers, portending an increased radiation-related risk. International scientific societies working in the field should collaborate to endorse radioprotection training, promote reliable radiation dose assessment, and support the adoption of radioprotection shielding dedicated to interventional echocardiographers

    Quantification of the relative contribution of the different right ventricular wall motion components to right ventricular ejection fraction

    Get PDF
    Abstract Three major mechanisms contribute to right ventricular (RV) pump function: (i) shortening of the longitudinal axis with traction of the tricuspid annulus towards the apex; (ii) inward movement of the RV free wall; (iii) bulging of the interventricular septum into the RV and stretching the free wall over the septum. The relative contribution of the aforementioned mechanisms to RV pump function may change in different pathological conditions. Our aim was to develop a custom method to separately assess the extent of longitudinal, radial and anteroposterior displacement of the RV walls and to quantify their relative contribution to global RV ejection fraction using 3D data sets obtained by echocardiography. Accordingly, we decomposed the movement of the exported RV beutel wall in a vertex based manner. The volumes of the beutels accounting for the RV wall motion in only one direction (either longitudinal, radial, or anteroposterior) were calculated at each time frame using the signed tetrahedron method. Then, the relative contribution of the RV wall motion along the three different directions to global RV ejection fraction was calculated either as the ratio of the given direction’s ejection fraction to global ejection fraction and as the frame-by-frame RV volume change (∆V/∆t) along the three motion directions. The ReVISION (Right VentrIcular Separate wall motIon quantificatiON) method may contribute to a better understanding of the pathophysiology of RV mechanical adaptations to different loading conditions and diseases

    Methodological approach for the assessment of ultrasound reproducibility of cardiac structure and function: a proposal of the study group of Echocardiography of the Italian Society of Cardiology (Ultra Cardia SIC) Part I

    Get PDF
    When applying echo-Doppler imaging for either clinical or research purposes it is very important to select the most adequate modality/technology and choose the most reliable and reproducible measurements. Quality control is a mainstay to reduce variability among institutions and operators and must be obtained by using appropriate procedures for data acquisition, storage and interpretation of echo-Doppler data. This goal can be achieved by employing an echo core laboratory (ECL), with the responsibility for standardizing image acquisition processes (performed at the peripheral echo-labs) and analysis (by monitoring and optimizing the internal intra- and inter-reader variability of measurements). Accordingly, the Working Group of Echocardiography of the Italian Society of Cardiology decided to design standardized procedures for imaging acquisition in peripheral laboratories and reading procedures and to propose a methodological approach to assess the reproducibility of echo-Doppler parameters of cardiac structure and function by using both standard and advanced technologies. A number of cardiologists experienced in cardiac ultrasound was involved to set up an ECL available for future studies involving complex imaging or including echo-Doppler measures as primary or secondary efficacy or safety end-points. The present manuscript describes the methodology of the procedures (imaging acquisition and measurement reading) and provides the documentation of the work done so far to test the reproducibility of the different echo-Doppler modalities (standard and advanced). These procedures can be suggested for utilization also in non referall echocardiographic laboratories as an "inside" quality check, with the aim at optimizing clinical consistency of echo-Doppler data

    Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation

    Get PDF
    BACKGROUND: Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF. METHODS: A total of 78 patients were included in this study. Fifty-five with sinus rhythm (group A) and 23 having AF (group B). 4B and SB 3DE was performed in all patients. LV volumes and EF was determined by these two modalities and inter- and intraobserver variability was analyzed. RESULTS: SB modality showed significantly lower inter- and intraobserver variability in group B in comparison to 4B when measuring LV volumes and EF, except for end-systolic volume (ESV) in intraobserver analysis. There were significant differences when calculating the LV volumes (p<0.001) and EF (p<0.05) with SB in comparison to 4B in group B. CONCLUSION: Single-beat three-dimensional full volume acquisition seems to be superior to four-beat ECG-gated acquisition in measuring left ventricular volumes and ejection fraction in patients having atrial fibrillation. The variability is significantly lower both for ejection fraction and left ventricular volumes
    corecore