    Residual stress in plasma sprayed ceramic turbine tip and gas path seal specimens

    Get PDF
    The residual stresses in a ceramic sheet material used for turbine blade tip gas path seals, were estimated. These stresses result from the plasma spraying process which leaves the surface of the sheet in tension. To determine the properties of plasma sprayed ZrO2-Y2O3 sheet material, its load deflection characteristics were measured. Estimates of the mechanical properties for sheet materials were found to differ from those reported for plasma sprayed bulk materials

    Radiation-induced insulator discharge pulses in the CRRES internal discharge monitor satellite experiment

    Get PDF
    The Internal Discharge Monitor (IDM) was designed to observe electrical pulses from common electrical insulators in space service. The sixteen insulator samples included twelve planar printed circuit boards and four cables. The samples were fully enclosed, mutually isolated, and space radiation penetrated 0.02 cm of aluminum before striking the samples. Pulsing began on the seventh orbit, the maximum pulse rate occurred on the seventeenth orbit when 13 pulses occurred, and the pulses slowly diminished to about one per 3 orbits six months later. After 8 months, the radiation belts abruptly increased and the pulse rates attained a new high. These pulse rates were in agreement with laboratory experience on shorter time scales. Several of the samples never pulsed. If the pulses were not confined within IDM, the physical processes could spread to become a full spacecraft anomaly. The IDM results indicate the rate at which small insulator pulses occur. Small pulses are the seeds of larger satellite electrical anomalies. The pulse rates are compared with space radiation intensities, L shell location, and spectral distributions from the radiation spectrometers on the Combined Release and Radiation Effects Satellite

    Cyclic mutually unbiased bases, Fibonacci polynomials and Wiedemann's conjecture

    Full text link
    We relate the construction of a complete set of cyclic mutually unbiased bases, i. e., mutually unbiased bases generated by a single unitary operator, in power-of-two dimensions to the problem of finding a symmetric matrix over F_2 with an irreducible characteristic polynomial that has a given Fibonacci index. For dimensions of the form 2^(2^k) we present a solution that shows an analogy to an open conjecture of Wiedemann in finite field theory. Finally, we discuss the equivalence of mutually unbiased bases.Comment: 11 pages, added chapter on equivalenc

    The effect of annealing on the creep of plasma sprayed ceramics

    Get PDF
    The creep of plasma sprayed ZrO2-8Y2O3 was measured at temperatues from 98 to 1250 C (180 to 220 F), and compared to creep of identical samples after annealing at temperatures from 98 to 1316 C (1800 to 2400 F). Loads and temperatures which produced significant creep of as sprayed ceramics produced no creep after annealing

    Film and interstitial formation of metals in plasma-sprayed ceramics

    Get PDF
    A method is described to electrodeposit noble metals such as platinum and ordinary metals such as copper on and within plasma-sprayed ceramic materials and ceramic fiber materials. Low-density ceramic fiber bodies were vacuum impregnated with plating solution and attached to an electrode. Light micrographs illustrating the density and location of deposited materials are presented and discussed. Voids in the plasma-sprayed ceramic were filled with deposits that vary from spherical to lens-shaped circular and have particle size corresponding to the full range of void size. Multiple coatings of ceramic and metal can be sequenced

    Correlation of compressive stress with spalling of plasma sprayed ceramic materials

    Get PDF
    Ceramics on metal substrates for potential use as high temperature seals or other applications are exposed to forces originating from differences in thermal expansion between the ceramic and the metal substrate. This report develops a relationship between the difference in expansion of the ceramic and the substrate, defines conditions under which shear between the ceramic and the substrate occurs, and those under which bending forces are produced in the ceramic. The off-axis effect of compression forces resulting from high temperature plastic flow of the ceramic producing buckling of the ceramic is developed. Shear is associated with the edge or boundary stresses on the component while bending is associated with the distortion of an interior region. Both modes are significant in predicting life of the ceramic

    Accuracy of Emergency Medical Services Dispatcher and Crew Diagnosis of Stroke in Clinical Practice.

    Get PDF
    BACKGROUND: Accurate recognition of stroke symptoms by Emergency Medical Services (EMS) is necessary for timely care of acute stroke patients. We assessed the accuracy of stroke diagnosis by EMS in clinical practice in a major US city. METHODS AND RESULTS: Philadelphia Fire Department data were merged with data from a single comprehensive stroke center to identify patients diagnosed with stroke or TIA from 9/2009 to 10/2012. Sensitivity and positive predictive value (PPV) were calculated. Multivariable logistic regression identified variables associated with correct EMS diagnosis. There were 709 total cases, with 400 having a discharge diagnosis of stroke or TIA. EMS crew sensitivity was 57.5% and PPV was 69.1%. EMS crew identified 80.2% of strokes with National Institutes of Health Stroke Scale (NIHSS) ≥5 and symptom durationmodel, correct EMS crew diagnosis was positively associated with NIHSS (NIHSS 5-9, OR 2.62, 95% CI 1.41-4.89; NIHSS ≥10, OR 4.56, 95% CI 2.29-9.09) and weakness (OR 2.28, 95% CI 1.35-3.85), and negatively associated with symptom duration \u3e270 min (OR 0.41, 95% CI 0.25-0.68). EMS dispatchers identified 90 stroke cases that the EMS crew missed. EMS dispatcher or crew identified stroke with sensitivity of 80% and PPV of 50.9%, and EMS dispatcher or crew identified 90.5% of patients with NIHSS ≥5 and symptom duration \u3c6 \u3eh. CONCLUSION: Prehospital diagnosis of stroke has limited sensitivity, resulting in a high proportion of missed stroke cases. Dispatchers identified many strokes that EMS crews did not. Incorporating EMS dispatcher impression into regional protocols may maximize the effectiveness of hospital destination selection and pre-notification

    Borrelia lonestari DNA in adult Amblyomma americanum ticks, Alabama.

    Get PDF
    Polymerase chain reaction analysis of 204 Amblyomma americanum and 28 A. maculatum ticks collected in August 1999 near the homes of patients with southern tick-associated rash illness and in control areas in Choctaw County, Alabama, showed Borrelia lonestari flagellin gene sequence from two adult A. americanum. The presence of B. lonestari in A. americanum ticks from Alabama suggests that this suspected pathogen may be widespread in the southeastern United States

    In Vitro Hydrodynamic Assessment of a New Transcatheter Heart Valve Concept (the TRISKELE)

    Get PDF
    This study presents the in vitro hydrodynamic assessment of the TRISKELE, a new system suitable for transcatheter aortic valve implantation (TAVI), aiming to mitigate the procedural challenges experienced with current technologies. The TRISKELE valve comprises three polymeric leaflet and an adaptive sealing cuff, supported by a novel fully retrievable self-expanding nitinol wire frame. Valve prototypes were manufactured in three sizes of 23, 26, and 29 mm by automated dip-coating of a biostable polymer, and tested in a hydrodynamic bench setup in mock aortic roots of 21, 23, 25, and 27 mm annulus, and compared to two reference valves suitable for equivalent implantation ranges: Edwards SAPIEN XT and Medtronic CoreValve. The TRISKELE valves demonstrated a global hydrodynamic performance comparable or superior to the controls with significant reduction in paravalvular leakage. The TRISKELE valve exhibits enhanced anchoring and improved sealing. The valve is currently under preclinical investigation

    Thermomechanical design criteria for ceramic-coated surfaces

    Get PDF
    Some early history of ceramic applications is presented. Finite element modeling of components to determine service and fabrication loads found inelastic behavior and residual stresses to be significant to component life. Inelastic behavior mitigates peak strains but enhances residual strains. Results of furnace, Mach 0.3 burner, and engine tests are discussed and categorized into design criteria (loading, geometry, fabrication, materials, analysis, and testing). These design rules and finite element analyses are brought to bear on two test cases: turboshaft engine seals, and rocket thrust chambers
    • …