97 research outputs found

    The potential of spring distraction to dynamically correct complex spinal deformities in the growing child

    Get PDF
    Purpose: Current treatment of progressive early onset scoliosis involves growth-friendly instrumentation if conservative treatment fails. These implants guide growth by passive sliding or repeated lengthenings. None of these techniques provide dynamic correction after implantation. We developed the spring distraction system (SDS), by using one or multiple compressed springs positioned around a standard sliding rod, to provide active continuous distraction of the spine to stimulate growth and further correction. The purpose of this study was to determine feasibility and proof of concept of the SDS. Methods: We developed a versatile, dynamic spring distraction system for patients who would benefit from active continuous distraction. This prospective case series evaluates four patients with exceptional and progressive congenital spine deformities. Results: Four patients had a mean age of 6.8 years at surgery with a mean follow-up of 36 months (range 25–45). The mean progressive thoracic lordosis, which was the reason for initiating surgical treatment in two patients, changed from 32° lordosis preoperatively to 1° kyphosis post-operatively. During follow-up, this further improved to 32° thoracic kyphosis. In the two other patients, with cervicothorcacic scoliosis, the main coronal curve improved from 79° pre-operatively to 56° post-operatively and further improved to 42°. The mean T1-S1 spine growth during follow-up for all patients was 1.3 cm/year. There was one reoperation because of skin problems and no device-failures. Conclusion: These early results show the feasibility and the proof of concept of spring-based distraction as a dynamic growth-enhancing system with the potential of further correction of the deformity after implantation

    Громадська робота як чинник повсякденного життя вчителя

    Get PDF
    Treatment and reconstruction of large bone defects, delayed unions, and nonunions is challenging and has resulted in an ongoing search for novel tissue-engineered therapies. Bone morphogenetic protein-2 (BMP-2) gene therapy is a promising strategy to provide sustained production of BMP-2 locally. Alginate polymer-based nonviral gene therapy with BMP-2 plasmid DNA (pBMP-2) in constructs with multipotent mesenchymal stromal cells (MSCs) has resulted in prolonged gene expression and bone formation in vivo. To further translate this technology toward larger animal models, important issues remain to be investigated, such as the necessity of seeded cells as a target for gene therapy. For that purpose, a large animal-screening model in an orthotopic location, with fully separated chambers, was investigated. Four cylinder-shaped implants were placed in the iliac crests of ten goats. Polycaprolactone tubes around each implant allowed bone ingrowth from the underlying bone and bone marrow and ensured separation of the experimental conditions. An empty tube showed low levels of spontaneous bone ingrowth, and implantation of autologous bone indicated proper bone function with respect to remodeling and resorption. Control ceramic scaffolds were compared to scaffolds containing pBMP-2 either or not combined with seeded MSCs. Fluorochrome incorporation evaluated at 3, 6, and 9 weeks and histomorphometry at 12 weeks after implantation revealed clear differences between the groups, with pBMP-2 combined with MSCs being the most effective. The BMP-2 was demonstrated in a variety of bone-residing cells through immunohistochemistry. Further analysis indicated that multinucleated giant cells might have an important role in transgene expression. Taken together, this work introduces a large animal model for studying bone formation at multiple sites simultaneously in an orthotopic location. The model appeared robust, showed no neighboring effects, and demonstrated effectivity of combined cell and gene therapy

    Схемотехническое моделирование и синтез активных СВЧ-фильтров на полевых транзисторах Шоттки

    Get PDF
    Разработаны схемы активных СВЧ-фильтров, пригодных для исполнения в виде гибридной или полупроводниковой микросхемы

    Induction of a representative idiopathic-like scoliosis in a porcine model using a multidirectional dynamic spring-based system

    Get PDF
    BACKGROUND CONTEXT: Scoliosis is a 3D deformity of the spine in which vertebral rotation plays an important role. However, no treatment strategy currently exists that primarily applies a continuous rotational moment over a long period of time to the spine, while preserving its mobility. We developed a dynamic, torsional device that can be inserted with standard posterior instrumentation. The feasibility of this implant to rotate the spine and preserve motion was tested in growing mini-pigs. PURPOSE: To test the quality and feasibility of the torsional device to induce the typical axial rotation of scoliosis while maintaining growth and mobility of the spine. STUDY DESIGN: Preclinical animal study with 14 male, 7 month old Gottingen mini-pigs. Comparison of two scoliosis induction methods, with and without the torsional device, with respect to 3D deformity and maintenance of the scoliosis after removal of the implants. METHODS: Fourteen mini-pigs received either a unilateral tether-only (n=6) or a tether combined with a contralateral torsional device (n=8). X-rays and CT-scans were made post-operative, at 8 weeks and at 12 weeks. Flexibility of the spine was assessed at 12 weeks. In 3 mini-pigs per condition, the implants were removed and the animals were followed until no further correction was expected. RESULTS: At 12 weeks the tether-only group yielded a coronal Cobb angle of 16.8±3.3°For the tether combined with the torsional device this was 22.0±4.0°. The most prominent difference at 12 weeks was the axial rotation with 3.6±2.8° for the tether-only group compared to 18.1±4.6° for the tether-torsion group. Spinal growth and flexibility remained normal and comparable for both groups. After removal of the devices, the induced scoliosis reduced by 41% in both groups. There were no adverse tissue reactions, implant complications or infections. CONCLUSION: The present study indicates the ability of the torsional device combined with a tether to induce a flexible idiopathic-like scoliosis in mini-pigs. The torsional device was necessary to induce the typical axial rotation found in human scoliosis. Clinical significance: The investigated torsional device could induce apical rotation in a flexible and growing spine. Whether this may be used to reduce a scoliotic deformity remains to be investigated

    Уровень провоспалительных цитокинов внутриматочных смывов при гиперплазиях эндометрия

    Get PDF
    Проведено вивчення змін рівня прозапальних цитокінів ІЛ -1ß, ІЛ -6 та ФНП-α в маткових змивах у жінок з різними видами гіперплазій ендометрію. Встановлено, що формування гіперплазії ендометрію супроводжується активацією прозапальних цитокінів. Найбільш виражені зміни виявлені при комплексній гіперплазії ендометрію. Запальний процес в урогенітальної системі сприяє більш вираженому зростанню рівня цитокінів в маткових змивах. Оцінка вираженості змін в рівні цитокінів маткових змивів може використовуватися в якості додаткового критерію, що характеризує гіперплазії ендометрію, для оцінки формування запальних змін в ендометрії при його гіперплазії і для оцінки прогнозу перебігу гіперплазій.Levels of proinflammatory cytokines IL-1ß, IL-6 and TNF-α in uterine lavage fluid of women with different types of endometrial hyperplasia were studied. It is established that the formation of endometrial hyperplasia is associated with activation of proinflammatory cytokines. The most intensive changes were found in complex endometrial hyperplasia. Inflammation in the urogenital system leads to more intensive increase of cytokines level in the uterine washout. Investigation of changes in cytokines levels in uterine lavage fluid can be used as an additional criterion for characteristics of endometrial hyperplasia, to assess the formation of inflammatory changes in the endometrium and for prognosis of hyperplasia

    Three-dimensional correction of scoliosis by a double spring reduction system as a dynamic internal brace:a pre-clinical study in Göttingen minipigs

    Get PDF
    BACKGROUND CONTEXT: Adolescent idiopathic scoliosis (AIS) is a major skeletal deformity that is characterized by a combination of apical rotation, lateral bending and apical lordosis. To provide full 3D correction, all these deformations should be addressed. We developed the Double Spring Reduction (DSR) system, a (growth-friendly) concept that continuously corrects the deformity through two different elements: A posterior convex Torsional Spring Implant (TSI) that provides a derotational torque at the apex, and a concave Spring Distraction System (SDS), which provides posterior, concave distraction to restore thoracic kyphosis. PURPOSE: To determine whether the DSR components are able to correct an induced idiopathic-like scoliosis and to compare correction realized by the TSI alone to correction enforced by the complete DSR implant. STUDY DESIGN/SETTING: Preclinical randomized animal cohort study. PATIENT SAMPLE: Twelve growing Göttingen minipigs. OUTCOME MEASURES: Coronal Cobb angle, T10-L3 lordosis/kyphosis, apical axial rotation, relative anterior lengthening. METHODS: All mini-pigs received the TSI with a contralateral tether to induce an idiopathic-like scoliosis with apical rotation (mean Cobb: 20.4°; mean axial apical rotation: 13.1°, mean lordosis: 4.9°). After induction, the animals were divided into two groups: One group (N=6) was corrected by TSI only (TSI only-group), another group (N=6) was corrected by a combination of TSI and SDS (DSR-group). 3D spinal morphology on CT was compared between groups over time. After 2 months of correction, animals were euthanized. RESULTS: Both intervention groups showed excellent apical derotation (TSI only-group: 15.0° to 5.4°; DSR-group: 11.2° to 3.5°). The TSI only-group showed coronal Cobb improvement from 22.5° to 6.0°, while the DSR-group overcorrected the 18.3° Cobb to -9.2°. Lordosis was converted to kyphosis in both groups (TSI only-group: -4.6° to 4.3°; DSR-group: -5.2° to 25.0°) which was significantly larger in the DSR-group (p<.001). CONCLUSIONS: The TSI alone realized strong apical derotation and moderate correction in the coronal and sagittal plane. The addition of distraction on the posterior concavity resulted in more coronal correction and reversal of induced lordosis into physiological kyphosis. CLINICAL SIGNIFICANCE: This study shows that dynamic spring forces could be a viable method to guide the spine towards healthy alignment, without fusing it or inhibiting its growth

    Health-related quality of life in early onset scoliosis patients treated with the spring distraction system:what to expect in the first 2 years after surgery

    Get PDF
    Purpose: The Spring Distraction System (SDS) is a novel “growth-friendly” implant for the treatment of Early-Onset Scoliosis (EOS). This prospective study aims to determine the evolution of the “24-Item Early-Onset Scoliosis Questionnaire” (EOSQ-24) scores during 2-year follow-up after SDS surgery. Secondary aims include investigating the relation between EOSQ-24 scores and EOS etiology, and evaluating the impact of an unplanned return to the operating room (UPROR) on HRQoL. Methods: All SDS patients with at least 2-year follow-up were included. Caregivers completed the EOSQ-24 pre-operatively, post-operatively, and at 6, 12, and 24 month follow-up. Mean total and -domain scores were graphed over time. Repeated-measures ANOVA analyzed the influence of etiology on EOSQ-24 scores. Multiple regression analyzed associations between UPRORs and EOSQ-24 scores. Results: Forty-nine patients were included. Mean total EOSQ-24 scores decreased from 70 pre-operatively to 66 post-operatively, then gradually increased to 75 (24 months). Most domains exhibited changes over time, with initial declines, but eventually surpassing pre-operative levels after 2-year follow-up. Neuromuscular/Syndromic patients had lower scores, but showed similar improvements over time compared with other etiologies. Multiple regression showed lower Parental Burden domain score (− 14 points) in patients with UPRORs, although no significant reductions were found in total score, or in other domains. Conclusion: HRQoL decreases immediately following SDS surgery but quickly recovers and exceeds pre-operative levels at 2-year follow-up in all domains. Neuromuscular/Syndromic patients have lower initial scores, but progress similarly over time. UPRORs do not influence EOSQ-24 scores, except for a negative impact on the Parental Burden domain in the short term. Level of Evidence: III.</p

    A new in vivo screening model for posterior spinal bone formation: comparison of ten calcium phosphate ceramic material treatments

    Get PDF
    This study presents a new screening model for evaluating the influence of multiple conditions on the initial process of bone formation in the posterior lumbar spine of a large animal. This model uses cages designed for placement on the decorticated transverse process of the goat lumbar spine. Five conduction channels per cage, each be defined by a different material treatment, are open to both the underlying bone and overlying soft tissue. The model was validated in ten adult Dutch milk goats, with each animal implanted with two cages containing a total of ten calcium phosphate material treatments according to a randomized complete block design. The ten calcium phosphate ceramic materials were created through a combination of material chemistry (BCP, TCP, HA), sintering temperature (low, medium, high), calcination and surface roughness treatments. To monitor the bone formation over time, fluorochrome markers were administered at 3, 5 and 7 weeks and the animals were sacrificed at 9 weeks after implantation. Bone formation in the conduction channels was investigated by histology and histomorphometry of non-decalcified sections using traditional light and epifluorescent microscopy. According to both observed and measured bone formation parameters, materials were ranked in order of increasing magnitude as follows: low sintering temperature BCP (rough and smooth)≈medium sintering temperature BCP≈TCP>calcined low sintering temperature HA>non-calcined low sintering temperature HA>high sintering temperature BCP (rough and smooth)>high sintering temperature HA (calcined and non-calcined). These results agree closely with those obtained in previous studies of osteoconduction and bioactivity of ceramics thereby validating the screening model presented in this study

    Orthopaedic management of Hurler’s disease after hematopoietic stem cell transplantation: a systematic review

    Get PDF
    The introduction of hematopoietic stem cell transplantation (HSCT) has significantly improved the life-span of Hurler patients (mucopolysaccharidosis type I-H, MPS I-H). Yet, the musculoskeletal manifestations seem largely unresponsive to HSCT. In order to facilitate evidence based management, the aim of the current study was to give a systematic overview of the orthopaedic complications and motor functioning of Hurler's patients after HSCT. A systematic review was conducted of the medical literature published from January 1981 to June 2010. Two reviewers independently assessed all eligible citations, as identified from the Pubmed and Embase databases. A pre-developed data extraction form was used to systematically collect information on the prevalence of radiological and clinical signs, and on the orthopaedic treatments and outcomes. A total of 32 studies, including 399 patient reports were identified. The most frequent musculoskeletal abnormalities were odontoid hypoplasia (72%), thoracolumbar kyphosis (81%), genu valgum (70%), hip dysplasia (90%) and carpal tunnel syndrome (63%), which were often treated surgically during the first decade of life. The overall complication rate of surgical interventions was 13.5%. Motor functioning was further hampered due to reduced joint mobility, hand dexterity, motor development and longitudinal growth. Stem cell transplantation does not halt the progression of a large range of disabling musculoskeletal abnormalities in Hurler's disease. Although prospective data on the quantification, progression and treatment of these deformities were very limited, early surgical intervention is often advocated. Prospective data collection will be mandatory to achieve better evidence on the effect of treatment strategies

    The Percentage of Amplitude Decrease Warning Criteria for Transcranial MEP Monitoring

    Get PDF
    Muscle motor evoked potentials (MEPs) from transcranial electrical stimulation (TES) became a standard technique for monitoring the motor functions of the brain and spinal cord at risk during spinal and brain surgery. However, a wide range of criteria based on the percentage of amplitude decrease is used in practice. A survey of the current literature on clinical outcome parameters reveals a variety of percentages in a range of 30% to 100% (50% to 100% spinal procedures) with no consensus. The interpretation of muscle MEPs is hampered by their sensitivity to many interfering factors. Trial-to-trial MEP variations may partly be reduced by controllable parameters of which TES parameters are in the hands of the neuromonitorist. We propose an operational model based on basic neurophysiologic knowledge to interpret the characteristics of MEP-TES voltage curves and predict the influences of the location on the sigmoid voltage curve on spontaneous MEP-variations and influences of factors affecting the voltage curve. The model predicts a correlation between the slope, expressed by a gain, and variations of muscle MEP amplitudes. This complies with two case examples. The limited specificity/sensitivity of warning criteria based on the percentage of amplitude reduction can possibly be improved by developing standards for set-up procedures of TES paradigms. These procedures include strategies for desensitizing MEPs for variations of controllable parameters. The TES voltage or current is a feasible controlling parameter and should be related to the motor threshold and the onset of the supramaximal level being landmarks of MEP-voltage functions. These parameters may offer a valuable addition to multicenter outcome studies
    corecore