9 research outputs found

    Mathematical model combined with microdosimetric kinetic model for tumor volume calculation in stereotactic body radiation therapy

    No full text
    Abstract We proposed a new mathematical model that combines an ordinary differential equation (ODE) and microdosimetric kinetic model (MKM) to predict the tumor-cell lethal effect of Stereotactic body radiation therapy (SBRT) applied to non-small cell lung cancer (NSCLC). The tumor growth volume was calculated by the ODE in the multi-component mathematical model (MCM) for the cell lines NSCLC A549 and NCI-H460 (H460). The prescription doses 48 Gy/4 fr and 54 Gy/3 fr were used in the SBRT, and the effect of the SBRT on tumor cells was evaluated by the MKM. We also evaluated the effects of (1) linear quadratic model (LQM) and the MKM, (2) varying the ratio of active and quiescent tumors for the total tumor volume, and (3) the length of the dose-delivery time per fractionated dose (tinter) on the initial tumor volume. We used the ratio of the tumor volume at 1 day after the end of irradiation to the tumor volume before irradiation to define the radiation effectiveness value (REV). The combination of MKM and MCM significantly reduced REV at 48 Gy/4 fr compared to the combination of LQM and MCM. The ratio of active tumors and the prolonging of tinter affected the decrease in the REV for A549 and H460 cells. We evaluated the tumor volume considering a large fractionated dose and the dose-delivery time by combining the MKM with a mathematical model of tumor growth using an ODE in lung SBRT for NSCLC A549 and H460 cells

    The Relationship between the Contouring Time of the Metal Artifacts Area and Metal Artifacts in Head and Neck Radiotherapy

    No full text
    (1) Background: The impacts of metal artifacts (MAs) on the contouring workload for head and neck radiotherapy have not yet been clarified. Therefore, this study evaluated the relationship between the contouring time of the MAs area and MAs on head and neck radiotherapy treatment planning. (2) Methods: We used treatment planning computed tomography (CT) images for head and neck radiotherapy. MAs were classified into three severities by the percentage of CT images containing MAs: mild (<25%), moderate (25–75%), and severe (>75%). We randomly selected nine patients to evaluate the relationship between MAs and the contouring time of the MAs area. (3) Results: The contouring time of MAs showed moderate positive correlations with the MAs volume and the number of CT images containing MAs. Interobserver reliability of the extracted MAs volume and contouring time were excellent and poor, respectively. (4) Conclusions: Our study suggests that the contouring time of MAs areas is related to individual commitment rather than clinical experience. Therefore, the development of software combining metal artifact reduction methods with automatic contouring methods is necessary to reducing interobserver variability and contouring workload

    Effect of setup error in the single-isocenter technique on stereotactic radiosurgery for multiple brain metastases

    No full text
    In conventional stereotactic radiosurgery (SRS), treatment of multiple brain metastases using multiple isocenters is time-consuming resulting in long dose delivery times for patients. A single-isocenter technique has been developed which enables the simultaneous irradiation of multiple targets at one isocenter. This technique requires accurate positioning of the patient to ensure optimal dose coverage. We evaluated the effect of six degrees of freedom (6DoF) setup errors in patient setups on SRS dose distributions for multiple brain metastases using a single-isocenter technique. We used simulated spherical gross tumor volumes (GTVs) with diameters ranging from 1.0 to 3.0 cm. The distance from the isocenter to the target's center was varied from 0 to 15 cm. We created dose distributions so that each target was entirely covered by 100% of the prescribed dose. The target's position vectors were rotated from 0 degrees-2.0 degrees and translated from 0-1.0 mm with respect to the three axes in space. The reduction in dose coverage for the targets for each setup error was calculated and compared with zero setup error. The calculated margins for the GTV necessary to satisfy the tolerance values for loss of GTV coverage of 3% to 10% were defined as coverage-based margins. In addition, the maximum isocenter to target distance for different 6DoF setup errors was calculated to satisfy the tolerance values. The dose coverage reduction and coverage-based margins increased as the target diameter decreased, and the distance and 6DoF setup error increased. An increase in setup error when a single-isocenter technique is used may increase the risk of missing the tumor; this risk increases with increasing distance from the isocenter and decreasing tumor size

    Definitive chemoradiotherapy with low-dose continuous 5-fluorouracil reduces hematological toxicity without compromising survival in esophageal squamous cell carcinoma patients

    No full text
    Background and purpose: To compare chemoradiotherapy (CRT) with low-dose continuous 5-fluorouracil (5FU) to CRT with 5FU+cisplatin (CDDP) for esophageal squamous cell carcinoma (ESCC) in a retrospective cohort study. Methods and materials: We reviewed the cases of Stage I–IV ESCC patients who underwent definitive CRT in 2000–2014. Concomitant chemotherapy was one of the three regimens: (1) high-dose intermittent 5FU and CDDP (standard-dose FP: SDFP), (2) low-dose continuous 5FU and CDDP (LDFP), or (3) low-dose continuous 5FU (LD5FU). The general selection criteria for chemotherapy were: SDFP for patients aged <70 yrs; LDFP for those aged 70–74 yrs; LD5FU for those aged ≄75 yrs or with performance status (PS) ≄3. Propensity scores were derived with chemotherapy (LD5FU vs. 5FU+CDDP) as the dependent variable. Results: In a multivariate analysis, chemotherapy (LD5FU vs. SDFP, p = .24; LDFP vs. SDFP, p = .52) did not affect the overall survival (OS). LD5FU caused significantly less grade 3–4 leukopenia (9%) compared to SDFP (47%) and LDFP (44%) (p < .001). In a propensity-matched analysis, LD5FU affected neither OS (HR 1.06; 95%CI 0.55–2.05; p = .87) nor progression-free survival (HR 0.95, 95%CI 0.50–1.81; p = .87). Conclusion: CRT with low-dose continuous 5FU may be a less toxic option for elderly ESCC patients

    Efficacy and Safety of the Radiotherapy for Liver Cancer: Assessment of Local Controllability and Its Role in Multidisciplinary Therapy

    No full text
    This study investigated the efficacy and safety of radiotherapy as part of multidisciplinary therapy for advanced hepatocellular carcinoma (HCC). Clinical data of 49 HCC patients treated with radiotherapy were assessed retrospectively. The efficacy of radiotherapy was assessed by progression-free survival, disease control rate, and overall survival. Safety was assessed by symptoms and hematological assay, and changes in hepatic reserve function were determined by Child&ndash;Pugh score and albumin&ndash;bilirubin (ALBI) score. Forty patients underwent curative radiotherapy, and nine patients with portal vein tumor thrombus (PVTT) underwent palliative radiotherapy as part of multidisciplinary therapy. Local disease control for curative therapy was 80.0% and stereotactic body radiotherapy was 86.7% which was greater than that of conventional radiotherapy (60.0%). Patients with PVTT had a median observation period of 651 days and 75% three-year survival when treated with multitherapy, including radiotherapy for palliative intent, transcatheter arterial chemoembolization, and administration of molecular targeted agents. No adverse events higher than grade 3 and no changes in the Child&ndash;Pugh score and ALBI score were seen. Radiotherapy is safe and effective for HCC treatment and can be a part of multidisciplinary therapy
    corecore