    Correction: Use of "biokitHSV-2 Rapid Assay" to improve the positive predictive value of Focus HerpeSelect HSV-2 ELISA

    Get PDF
    As the competing interests for only the previous calendar year were included in the published article and it is journal policy to list competing interests for the previous five years, a full declaration of interests for the authors is now published

    Use of "biokit HSV-2 Rapid Assay" to improve the positive predictive value of Focus HerpeSelect HSV-2 ELISA

    Get PDF
    BACKGROUND: Commercially available assays to detect antibodies to the herpes simplex virus type 2 (HSV-2)-specific glycoprotein gG-2 have markedly improved serologic diagnosis of HSV-2 infection. However, even tests with high specificity can have low positive predictive values in low prevalence populations. HSV-2 is a chronic, life-long viral infection that requires both medical attention and potential alterations in health care strategy. As such, the concern for false positive diagnoses is high confirmatory testing is routine for other viral serologies such as HIV and hepatitis C. We evaluated such a strategy for HSV-2 serology by using an easily performed commercial test, biokitHSV-2 rapid test ("Biokit"; Biokit USA, Lexington MA) as a confirmatory test for the widely used gG-2 specific serology ("Focus;" HerpeSelect HSV-2 ELISA; Focus Diagnostics, Cypress CA). METHODS: We tested 782 sera by Focus HSV-2 ELISA, Biokit, and the current gold standard test, Western blot (WB). RESULTS: The positive predictive value of the Focus HSV-2 ELISA increased from 80.5% to 95.6% when Biokit testing was performed on sera that were initially positive by Focus HSV-2 ELISA. Confirmatory testing increased the specificity markedly among sera with Focus EIA values between 1.1 and 3.5: only 35% of low positive (index values 1.1–3.5) Focus HSV-2 ELISA results confirmed as positive by Biokit and WB compared with 92% of those with index values >3.5. Mathematical modeling of the data resulted in expected positive predictive values over 98% for populations with antibody prevalences typical of clinical practices in the US and Europe. CONCLUSION: Confirmatory Biokit testing of positive Focus HSV-2 ELISA results is fast, easy, and effective in reducing falsely positive HSV-2 antibody results. Patients, clinicians, and laboratories could benefit from the enhanced specificity of this simple HSV-2 serologic test combination

    Comparison of focus HerpesSelect and Kalon HSV-2 gG2 ELISA serological assays to detect herpes simplex virus type 2 antibodies in a South African population.

    Get PDF
    INTRODUCTION: Sero-epidemiological studies of herpes simplex virus (HSV) type 2 infection in Africa remain difficult to interpret as a result of the high rate of false-positive results observed when using the new recombinant gG2 HSV-2 ELISA tests. The performance of two widely used gG2 ELISA was compared to derive an appropriate testing algorithm for use in South Africa. METHODS: Sera from 210 women attending family planning clinics in Johannesburg were tested using HerpeSelect and Kalon HSV-2 gG2 assays. Sera from 20 discordant pairs, 44 concordant positive and 33 concordant negative samples were further tested by HSV Western blot. The sensitivity and specificity of each test and of combination algorithms compared with Western blot were calculated. RESULTS: HerpeSelect had a sensitivity of 98% (95% CI 95 to 100) and specificity of 61% (95% CI 48 to 74). Kalon was less sensitive (89%, 95% CI 83 to 94) but more specific (85%, 95% CI 61 to 100). Seroprevalence may have been overestimated by as much as 14% by HerpeSelect. Specificity was improved by raising the cut-off index for the determination of a positive result for HerpeSelect (to >or=3.5), but not for Kalon. HIV-1 infection reduced the specificity of HerpeSelect to 30%. Improved sensitivity and specificity were obtained by a two-test algorithm using HerpeSelect (>or=3.5) as the first test and Kalon to resolve equivocal results (sensitivity 92%, 95% CI 82 to 98; specificity 91%, 95% CI 79 to 98). CONCLUSION: Newer HSV-2 serological tests have low specificity in this South African population with a high HIV-1 prevalence. Two-step testing strategies could provide rational testing alternatives to Western blot

    Efficacy Results of a Trial of a Herpes Simplex Vaccine

    Get PDF
    Two previous studies of a herpes simplex virus type 2 (HSV-2) subunit vaccine containing glycoprotein D in HSV-discordant couples revealed 73% and 74% efficacy against genital disease in women who were negative for both HSV type 1 (HSV-1) and HSV-2 antibodies. Efficacy was not observed in men or HSV-1 seropositive women

    Plasma viral loads during early HIV-1 infection are similar in subtype C- and non-subtype C-infected African seroconverters.

    No full text
    Recent data suggest that infection with human immunodeficiency virus type 1 (HIV-1) subtype C results in prolonged high-level viremia (>5 log10 copies/mL) during early infection. We examined the relationship between HIV-1 subtype and plasma viremia among 153 African seroconverters. Mean setpoint viral loads were similar for C and non-C subtypes: 4.36 vs 4.42 log10 copies/mL (P = .61). The proportion of subtype C-infected participants with viral loads >5 log10 copies/mL was not greater than the proportion for those with non-C infection. Our data do not support the hypothesis that higher early viral load accounts for the rapid spread of HIV-1 subtype C in southern Africa

    Characteristics of HIV-1 Discordant Couples Enrolled in a Trial of HSV-2 Suppression to Reduce HIV-1 Transmission: The Partners Study

    Get PDF
    Background: The Partners HSV-2/HIV-1 Transmission Study (Partners Study) is a phase III, placebo-controlled trial of daily acyclovir for genital herpes (HSV-2) suppression among HIV-1/HSV-2 co-infected persons to reduce HIV-1 transmission to their HIV-1 susceptible partners, which requires recruitment of HIV-1 serodiscordant heterosexual couples. We describe the baseline characteristics of this cohort. Methods: HIV-1 serodiscordant heterosexual couples, in which the HIV-1 infected partner was HSV-2 seropositive, had a CD4 count ≥250 cells/mcL and was not on antiretroviral therapy, were enrolled at 14 sites in East and Southern Africa. Demographic, behavioral, clinical and laboratory characteristics were assessed. Results: Of the 3408 HIV-1 serodiscordant couples enrolled, 67% of the HIV-1 infected partners were women. Couples had cohabitated for a median of 5 years (range 2–9) with 28% reporting unprotected sex in the month prior to enrollment. Among HIV-1 susceptible participants, 86% of women and 59% of men were HSV-2 seropositive. Other laboratory-diagnosed sexually transmitted infections were uncommon (500 relative to <350, respectively, p<0.001). Conclusions: The Partners Study successfully enrolled a cohort of 3408 heterosexual HIV-1 serodiscordant couples in Africa at high risk for HIV-1 transmission. Follow-up of this cohort will evaluate the efficacy of acyclovir for HSV-2 suppression in preventing HIV-1 transmission and provide insights into biological and behavioral factors determining heterosexual HIV-1 transmission. Trial Registration ClinicalTrials.gov NCT0019451

    Performance of the Focus and Kalon Enzyme-Linked Immunosorbent Assays for Antibodies to Herpes Simplex Virus Type 2 Glycoprotein G in Culture-Documented Cases of Genital Herpes

    No full text
    Glycoprotein G-based herpes simplex virus type 2 (HSV-2) enzyme-linked immunosorbent assays from Focus and Kalon were performed with specimens from 118 patients with culture-documented genital herpes episodes, and their results were compared. Sensitivity was 52% by Kalon and 86% by Focus for first HSV-2 episodes and 100% (for each of the two tests) for recurrent HSV-2. Median times to seroconversion were 120 days by the Kalon assay, 21 days by the Focus assay, and 68 days by Western blotting assay. Values for specificity were 100% (Kalon) and 93% (Focus)
    corecore