33 research outputs found

    Dealing with temporal inconsistency in automated computer forensic profiling

    Get PDF
    Computer profiling is the automated forensic examination of a computer system in order to provide a human investigator with a characterisation of the activities that have taken place on that system. As part of this process, the logical components of the computer system – components such as users, files and applications - are enumerated and the relationships between them discovered and reported. This information is enriched with traces of historical activity drawn from system logs and from evidence of events found in the computer file system. A potential problem with the use of such information is that some of it may be inconsistent and contradictory thus compromising its value. This work examines the impact of temporal inconsistency in such information and discusses two types of temporal inconsistency that may arise – inconsistency arising out of the normal errant behaviour of a computer system, and inconsistency arising out of deliberate tampering by a suspect – and techniques for dealing with inconsistencies of the latter kind. We examine the impact of deliberate tampering through experiments conducted with prototype computer profiling software. Based on the results of these experiments, we discuss techniques which can be employed in computer profiling to deal with such temporal inconsistencies

    Rhizobium radiobacter Endophthalmitis following Intravitreal Ranibizumab Injection.

    Get PDF
    We present the first reported case of acute endophthalmitis due to Rhizobium radiobacter after an intravitreal injection of ranibizumab for neovascular age-related macular degeneration

    Intravitreal bevacizumab injections for diabetic macular edema - predictors of response: a retrospective study

    Get PDF
    BACKGROUND: Outcomes of intravitreal antivascular endothelial growth factor injections are variable among patients with diabetic macular edema (DME). The aim of this study was to determine the ocular and systemic predictors of DME response to intravitreal bevacizumab (IVB). METHODS: Retrospective review over 2 years of 78 eyes from 54 patients. An anatomical response to IVB was defined as a 20% reduction in central macula thickness after the first course (three injections) of IVB. RESULTS: Twenty-eight percent of patients had an anatomical response after the first course of IVB. Systemic hypertension (odds ratio, 95% confidence interval: 12.1, 0.7-21) was a statistically significant predictor (P=0.025) of a good response to IVB, whereas previous macular laser was a statistically significant (P=0.0005) predictor of a poor response (0.07, 0.01-0.32). Sixty-eight percent of eyes underwent subsequent treatment for DME after the first course of IVB. The visual acuity gain at 24 months in hypertensive (0.7±3.6 letters) and nonhypertensive (5.2±3.7 letters) patients was not significantly different (P=0.41). CONCLUSION: Hypertension and previous macular laser were positive and negative predictors of response to IVB, respectively. However, long-term visual acuity changes were not significantly different between eyes with and without systemic hypertension

    Association of Steroid 5α-Reductase Type 3 Congenital Disorder of Glycosylation With Early-Onset Retinal Dystrophy

    Get PDF
    Importance: Steroid 5α-reductase type 3 congenital disorder of glycosylation (SRD5A3-CDG) is a rare disorder of N-linked glycosylation. Its retinal phenotype is not well described but could be important for disease recognition because it appears to be a consistent primary presenting feature. Objective: To investigate a series of patients with the same mutation in the SRD5A3 gene and thereby characterize its retinal manifestations and other associated features. Design, Setting and Participants: Seven affected individuals from 4 unrelated families with early-onset retinal dystrophy as a primary manifestation underwent comprehensive ophthalmic assessment, including retinal imaging and electrodiagnostic testing. Developmental and systemic findings were also recorded. Molecular genetic approaches, including targeted next-generation sequencing, autozygosity mapping, and apex microarray, were tried to reach a diagnosis; all participants were mutation negative. Whole-exome sequencing or whole-genome sequencing was used to identify the causative variant. Biochemical profiling was conducted to confirm a CDG type I defect. Patient phenotype data were collected over the course of ophthalmic follow-up, spanning a period of 20 years, beginning March 20, 1997, through September 15, 2016. Main Outcomes and Measures: Detailed clinical phenotypes as well as genetic and biochemical results. Results: The cohort consisted of 7 participants (5 females and 2 males) whose mean (SD) age at the most recent examination was 17.1 (3.9) years and who were all of South Asian ethnicity. Whole-exome sequencing and whole-genome sequencing identified the same homozygous SRD5A3 c.57G>A, p.(Trp19Ter) variant as the underlying cause of early-onset retinal dystrophy in each family. Detailed ocular phenotyping identified early-onset (aged ≤3 years) visual loss (mean [SD] best-corrected visual acuity, +0.95 [0.34] logMAR [20/180 Snellen]), childhood-onset nyctalopia, myopia (mean [SD] refractive error, -6.71 [-4.22]), and nystagmus. Six of the 7 patients had learning difficulties and psychomotor delay. Fundus autofluorescence imaging and optical coherence tomographic scans were abnormal in all patients, and electrodiagnostic testing revealed rod and cone dysfunction in the 5 patients tested. Conclusions and Relevance: Mutations in the SRD5A3 gene may cause early-onset retinal dystrophy, a previously underdescribed feature of the SRD5A3-CDG disorder that is progressive and may lead to serious visual impairment. SRD5A3 and other glycosylation disorder genes should be considered as a cause of retinal dystrophy even when systemic features are mild. Further delineation of SRD5A3-associated eye phenotypes can help inform genetic counseling for prognostic estimation of visual loss and disease progression

    Valacyclovir in the treatment of acute retinal necrosis

    Get PDF
    Background: To report the outcome of oral valacyclovir as the sole antiviral therapy for patients with acute retinal necrosis (ARN). Methods: This study reports a retrospective, interventional case series of nine consecutive patients with ten eyes with newly diagnosed ARN treated with oral valacyclovir as the sole antiviral agent. Eight patients received oral valacyclovir 2 g tid (Valtrex, GlaxoSmithKline) and one patient with impaired renal function received oral 1 g tid. The main outcome measures were response to treatment, time to initial response to treatment, time to complete resolution of retinitis, best corrected visual acuity (BCVA) at final follow-up, retinal detachment and development of recurrent or second eye disease. Results: Retinitis resolved in ten of ten (100%) affected eyes. The median time to initial detectable response was seven days and the median time to complete resolution was 21 days. A final BCVA of 20/40 or better was achieved in 6/10 (60%) of eyes. 3/10 eyes (30%) developed a retinal detachment. No patients developed either disease reactivation or second eye involvement over the course of the study (mean follow up 31 weeks, range 7 to 104 weeks). Conclusions: Treatment with oral valacyclovir as the sole antiviral therapy resulted in complete resolution of retinitis. Final BCVA and retinal detachment rate were comparable with previously reported outcomes for intravenous acyclovi

    The eye in rheumatology

    No full text

    The eye in rheumatology

    No full text

    A model for computer profiling

    Get PDF
    This paper discusses the use of models in automatic computer forensic analysis, and proposes and elaborates on a novel model for use in computer profiling, the computer profiling object model. The computer profiling object model is an information model which models a computer as objects with various attributes and inter-relationships. These together provide the information necessary for a human investigator or an automated reasoning engine to make judgements as to the probable usage and evidentiary value of a computer system. The computer profiling object model can be implemented so as to support automated analysis to provide an investigator with the information needed to decide whether manual analysis is required
    corecore