69 research outputs found

    The Focused Ultrasound Myoma Outcome Study (FUMOS); a retrospective cohort study on long-term outcomes of MR-HIFU therapy

    Get PDF
    Objectives: Since 2004, uterine fibroids have been treated with MR-HIFU, but there are persevering doubts on long-term efficacy to date. In the Focused Ultrasound Myoma Outcome Study (FUMOS), we evaluated long-term outcomes after MR-HIFU therapy, primarily to assess the reintervention rate. Methods: Data was retrospectively collected from 123 patients treated with MR-HIFU at our hospital from 2010 to 2017. Follow-up duration and baseline (MRI) characteristics were retrieved from medical records. Treatment failures, adverse events, and the nonperfused volume percentage (NPV%) were determined. Patients received a questionnaire about reinterventions, recovery time, satisfaction, and pregnancy outcomes. Restrictive treatment protocols were compared with unrestrictive (aiming for complete ablation) treatments. Subgroups were analyzed based on the achieved NPV < 50 or ≥ 50%. Results: Treatment failures occurred in 12.1% and the number of adverse events was 13.7%. Implementation of an unrestrictive treatment protocol significantly (p = 0.006) increased the mean NPV% from 37.4% [24.3–53.0] to 57.4% [33.5–76.5]. At 63.5 ± 29.0 months follow-up, the overall reintervention rate was 33.3% (n = 87). All reinterventions were performed within 34 months follow-up, but within 21 months in the unrestrictive group. The reintervention rate significantly (p = 0.002) decreased from 48.8% in the restrictive group (n = 43; follow-up 87.5 ± 7.3 months) to 18.2% in the unrestrictive group (n = 44; follow-up 40.0 ± 22.1 months). The median recovery time was 2.0 [1.0–7.0] days. Treatment satisfaction rate was 72.4% and 4/11 women completed family planning after MR-HIFU. Conclusions: The unrestrictive treatment protocol significantly increased the NPV%. Unrestrictive MR-HIFU treatments led to acceptable reintervention rates comparable to other reimbursed uterine-sparing treatments, and no reinterventions were reported beyond 21 months follow-up. Key Points: • All reinterventions were performe

    Use of multiparametric MRI to characterize uterine fibroid tissue types

    Get PDF
    Background: Although the biological characteristics of uterine fibroids (UF) have implications for therapy choice and effectiveness, there is limited MRI data about these characteristics. Currently, the Funaki classification and Scale

    Development and clinical evaluation of a 3-step modified manipulation protocol for MRI-guided high-intensity focused ultrasound of uterine fibroids

    Get PDF
    __Objectives:__ The clinical applicability of magnetic resonance image−guided high-intensity focused ultrasound (MR-HIFU) treatment of uterine fibroids is often limited due to inaccessible fibroids or bowel interference. The aim of this study was to implement a newly developed 3-step modified manipulation protocol and to evaluate its influence on the number of eligible women and treatment fai

    Combination of two fat saturation pulses improves detectability of glucose signals in carbon-13 MR spectroscopy

    Get PDF
    In order to improve the fat suppression performance of in vivo 13C-MRS operating at 3.0 Tesla, a phantom model study was conducted using a combination of two fat suppression techniques; a set of pulses for frequency (chemical shift) selective suppression (CHESS), and spatial saturation (SAT). By optimizing the slab thickness for SAT and the irradiation bandwidth for CHESS, the signals of the –13CH3 peak at 49 ppm and the –13CH2– peak at 26 ppm simulating fat components were suppressed to 5% and 19%, respectively. Combination of these two fat suppression pulses achieved a 53% increase of the height ratio of the glucose C1β peak compared with the sum of all other peaks, indicating better sensitivity for glucose signal detection. This method will be applicable for in vivo 13C-MRS by additional adjustment with the in vivo relaxation times of the metabolites

    Exploring label dynamics of velocity-selective arterial spin labeling in the kidney

    Get PDF
    Purpose: Velocity-selective arterial spin labeling (VSASL) has been proposed for renal perfusion imaging to mitigate planning challenges and effects of arterial transit time (ATT) uncertainties. In VSASL, label generation may shift in the vascular tree as a function of cutoff velocity. Here, we investigate label dynamics and especially the ATT of renal VSASL and compared it with a spatially selective pulsed arterial spin labeling technique, flow alternating inversion recovery (FAIR). Methods: Arterial spin labeling data were acquired in 7 subjects, using free-breathing dual VSASL and FAIR with five postlabeling delays: 400, 800, 1200, 2000, and 2600 ms. The VSASL measurements were acquired with cutoff velocities of 5, 10, and 15 cm/s, with anterior–posterior velocity-encoding direction. Cortical perfusion-weighted signal, temporal SNR, quantified renal blood flow, and arterial transit time were reported. Results: In contrast to FAIR, renal VSASL already showed fairly high signal at the earliest postlabeling delays, for all cutoff velocities. The highest VSASL signal and temporal SNR was obtained with a cutoff velocity of 10 cm/s at postlabeling delay = 800 ms, which was earlier than for FAIR at 1200 ms. Fitted ATT on VSASL was ≤ 0 ms, indicating ATT insensitivity, which was shorter than for FAIR (189 ± 79 ms, P .05) with good correlations on subject level. Conclusion: Velocity-selective arterial spin labeling in the kidney reduces ATT sensitivity compared with the recommended pulsed arterial spin labeling method, as well as if cutoff velocity is increased to reduce spurious labeling due to motion. Thus, VSASL has potential as a method for time-efficient, single-time-point, free-breathing renal perfusion measurements, despite lower tSNR than FAIR

    Physical techniques in flavin research

    No full text

    MR venography segmentation using inertia tensors

    No full text
    International audienc
    corecore