    A risk assessment of automated treatment planning and recommendations for clinical deployment

    Get PDF
    CITATION: Kisling, K. et al. 2019. A risk assessment of automated treatment planning and recommendations for clinical deployment. Medical Physics, 46(6): 2567-2574. doi:10.1002/mp.13552The original publication is available at https://aapm.onlinelibrary.wiley.com/journal/24734209Purpose: To assess the risk of failure of a recently developed automated treatment planning tool, the radiation planning assistant (RPA), and to determine the reduction in these risks with implementation of a quality assurance (QA) program specifically designed for the RPA. Methods: We used failure mode and effects analysis (FMEA) to assess the risk of the RPA. The steps involved in the workflow of planning a four-field box treatment of cervical cancer with the RPA were identified. Then, the potential failure modes at each step and their causes were identified and scored according to their likelihood of occurrence, severity, and likelihood of going undetected. Additionally, the impact of the components of the QA program on the detectability of the failure modes was assessed. The QA program was designed to supplement a clinic's standard QA processes and consisted of three components: (a) automatic, independent verification of the results of automated planning; (b) automatic comparison of treatment parameters to expected values; and (c) guided manual checks of the treatment plan. A risk priority number (RPN) was calculated for each potential failure mode with and without use of the QA program. Results: In the RPA automated treatment planning workflow, we identified 68 potential failure modes with 113 causes. The average RPN was 91 without the QA program and 68 with the QA program (maximum RPNs were 504 and 315, respectively). The reduction in RPN was due to an improvement in the likelihood of detecting failures, resulting in lower detectability scores. The top-ranked failure modes included incorrect identification of the marked isocenter, inappropriate beam aperture definition, incorrect entry of the prescription into the RPA plan directive, and lack of a comprehensive plan review by the physician. Conclusions: Using FMEA, we assessed the risks in the clinical deployment of an automated treatment planning workflow and showed that a specialized QA program for the RPA, which included automatic QA techniques, improved the detectability of failures, reducing this risk. However, some residual risks persisted, which were similar to those found in manual treatment planning, and human error remained a major cause of potential failures. Through the risk analysis process, we identified three key aspects of safe deployment of automated planning: (a) user training on potential failure modes; (b) comprehensive manual plan review by physicians and physicists; and (c) automated QA of the treatment plan.https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.13552Publisher’s versio

    Illustrated instructions for mechanical quality assurance of a medical linear accelerator

    No full text
    PurposeThe purpose of this study was to develop and test a set of illustrated instructions for effective training for mechanical quality assurance (QA) of medical linear accelerators (linac).MethodsIllustrated instructions were created for mechanical QA and underwent several steps of review, testing, and refinement. Eleven testers with no recent QA experience were then recruited from our radiotherapy department (one student, two computational scientists, and eight dosimetrists). This group was selected because they have experience of radiation therapy but no preconceived ideas about how to do QA. The following parameters were progressively decalibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (five testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (three testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (three testers). Testers were taught how to use the linac and then used the instructions to try to identify these errors. An experienced physicist observed each session, giving support on machine operation as necessary.ResultsTesters were able to follow the instructions. They determined gantry, collimator, and couch angle errors within 0.4°, 0.3°, and 0.9° of the actual changed values, respectively. Laser positions were determined within 1 mm and jaw positions within 2 mm. Couch position errors were determined within 2 mm and 3 mm for lateral/longitudinal and vertical errors, respectively. Accessory-positioning errors were determined within 1 mm. Optical distance indicator errors were determined within 2 mm when comparing with distance sticks and 6 mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff.ConclusionsInexperienced users were able to follow these instructions and catch errors within the criteria suggested by AAPM TG-142 for linacs used for intensity-modulated radiation therapy. These instructions are, therefore, suitable for QA training

    Automated treatment planning of postmastectomy radiotherapy

    Get PDF
    CITATION: Kisling, K., et al. 2019. Automated treatment planning of postmastectomy radiotherapy. Medical physics, 46(9), 3767–3775. https://doi.org/10.1002/mp.13586The original publication is available at https://aapm.onlinelibrary.wiley.com/journal/24734209Purpose: Breast cancer is the most common cancer in women globally and radiation therapy is a cornerstone of its treatment. However, there is an enormous shortage of radiotherapy staff, especially in low- and middle-income countries. This shortage could be ameliorated through increased automation in the radiation treatment planning process, which may reduce the workload on radiotherapy staff and improve efficiency in preparing radiotherapy treatments for patients. To this end, we sought to create an automated treatment planning tool for postmastectomy radiotherapy (PMRT). Methods: Algorithms to automate every step of PMRT planning were developed and integrated into a commercial treatment planning system. The only required inputs for automated PMRT planning are a planning computed tomography scan, a plan directive, and selection of the inferior border of the tangential fields. With no other human input, the planning tool automatically creates a treatment plan and presents it for review. The major automated steps are (a) segmentation of relevant structures (targets, normal tissues, and other planning structures), (b) setup of the beams (tangential fields matched with a supraclavicular field), and (c) optimization of the dose distribution by using a mix of high- and low-energy photon beams and field-in-field modulation for the tangential fields. This automated PMRT planning tool was tested with ten computed tomography scans of patients with breast cancer who had received irradiation of the left chest wall. These plans were assessed quantitatively using their dose distributions and were reviewed by two physicians who rated them on a three-tiered scale: use as is, minor changes, or major changes. The accuracy of the automated segmentation of the heart and ipsilateral lung was also assessed. Finally, a plan quality verification tool was tested to alert the user to any possible deviations in the quality of the automatically created treatment plans. Results: The automatically created PMRT plans met the acceptable dose objectives, including target coverage, maximum plan dose, and dose to organs at risk, for all but one patient for whom the heart objectives were exceeded. Physicians accepted 50% of the treatment plans as is and required only minor changes for the remaining 50%, which included the one patient whose plan had a high heart dose. Furthermore, the automatically segmented contours of the heart and ipsilateral lung agreed well with manually edited contours. Finally, the automated plan quality verification tool detected 92% of the changes requested by physicians in this review. Conclusions: We developed a new tool for automatically planning PMRT for breast cancer, including irradiation of the chest wall and ipsilateral lymph nodes (supraclavicular and level III axillary). In this initial testing, we found that the plans created by this tool are clinically viable, and the tool can alert the user to possible deviations in plan quality. The next step is to subject this tool to prospective testing, in which automatically planned treatments will be compared with manually planned treatments.https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.13586Publisher’s versio

    Addressing the Global Expertise Gap in Radiation Oncology: The Radiation Planning Assistant

    No full text
    PURPOSEAutomation, including the use of artificial intelligence, has been identified as a possible opportunity to help reduce the gap in access and quality for radiotherapy and other aspects of cancer care. The Radiation Planning Assistant (RPA) project was conceived in 2015 (and funded in 2016) to use automated contouring and treatment planning algorithms to support the efforts of oncologists in low- and middle-income countries, allowing them to scale their efforts and treat more patients safely and efficiently (to increase access).DESIGNIn this review, we discuss the development of the RPA, with a particular focus on clinical acceptability and safety/risk across jurisdictions as these are important indicators for the successful future deployment of the RPA to increase radiotherapy availability and ameliorate global disparities in access to radiation oncology.RESULTSRPA tools will be offered through a webpage, where users can upload computed tomography data sets and download automatically generated contours and treatment plans. All interfaces have been designed to maximize ease of use and minimize risk. The current version of the RPA includes automated contouring and planning for head and neck cancer, cervical cancer, breast cancer, and metastases to the brain.CONCLUSIONThe RPA has been designed to bring high-quality treatment planning to more patients across the world, and it may encourage greater investment in treatment devices and other aspects of cancer treatment

    Radiation planning assistant - a streamlined, fully automated radiotherapy treatment planning system

    No full text
    CITATION: Court, L. E., et al. 2018. Radiation planning assistant - a streamlined, fully automated radiotherapy treatment planning system. Journal of Visualized Experiments, 134:e57411, doi:10.3791/57411 (2018).The original publication is available at https://www.jove.comThe Radiation Planning Assistant (RPA) is a system developed for the fully automated creation of radiotherapy treatment plans, including volume-modulated arc therapy (VMAT) plans for patients with head/neck cancer and 4-field box plans for patients with cervical cancer. It is a combination of specially developed in-house software that uses an application programming interface to communicate with a commercial radiotherapy treatment planning system. It also interfaces with a commercial secondary dose verification software. The necessary inputs to the system are a Treatment Plan Order, approved by the radiation oncologist, and a simulation computed tomography (CT) image, approved by the radiographer. The RPA then generates a complete radiotherapy treatment plan. For the cervical cancer treatment plans, no additional user intervention is necessary until the plan is complete. For head/neck treatment plans, after the normal tissue and some of the target structures are automatically delineated on the CT image, the radiation oncologist must review the contours, making edits if necessary. They also delineate the gross tumor volume. The RPA then completes the treatment planning process, creating a VMAT plan. Finally, the completed plan must be reviewed by qualified clinical staff.https://www.jove.com/video/57411/radiation-planning-assistant-streamlined-fully-automated-radiotherapyPublisher's versio