8 research outputs found

    Development of an optical sandwich ELONA using a pair of DNA aptamers for yellow fever virus NS1

    No full text
    © 2022Here, we proposed an enzyme-linked oligonucleotide assay (ELONA) for yellow fever (YF) diagnosis that uses a pair of aptamers, YFns1-4 and YFns1-31. The aptamers were selected to specifically bind to nonstructural protein 1 (NS1), which is secreted at a high concentration after YF infection. We applied the aptamers which did not interfere with each other on binding to the NS1 in a sandwich ELONA. In the assay, the best detection sensitivity was obtained when the combination of YFns1-31 as a capture aptamer and YFns1-4 as a detect aptamer was used. The sensitivity could be attributed to the results of the direct ELONA with each YFns1-4 and YFns1-31; a great absorbance intensity and a broad detectable range of NS1, respectively. The sandwich ELONA achieved a low detection limit of 0.85 nM in buffer and was highly specific to the YFV-NS1 as its detection signals were significantly distinct from those of other flavivirus-derived NS1. In addition, the assay showed a desirable sensitivity in serum-spiked condition. Our developed sandwich ELONA can be a new practical and applicable serological diagnostics in YF endemic regions where other flaviviruses coexist and facilities for complex diagnostic tests are lacking.11Nsciescopu

    A Non-Electrolysis Bioelectric Effect for Gingivitis and Hygiene Contamination Biofilm Removal

    No full text
    A combinatorial biofilm treatment involving a low dose of antibiotics along with a small amount of electricity is known as the bioelectric effect (BE). When an external electric field or current is applied, biofilms can be affected by the resulting electrostatic force. Our group is researching the maximization of electrostatic force through the integration of both alternating and direct currents, with a voltage below the electrolysis threshold (0.82 V). To validate the efficacy of this technology, in the present work we investigated two major biofilm applications: (1) dentistry for oral biofilm infection and (2) hygiene for aerobic biofilm contamination. For each application, testing devices were developed in the form of a toothbrush and an evaporator cleaner, respectively. The dental clinical results demonstrated a 75% reduction in gingivitis compared to the non-BE applied group (n = 40, ANOVA, paired t-test, p n = 6, ANOVA, paired t-test, p < 0.05). In conclusion, this new BE technology showed efficacy in both dental- and hygiene-associated biofilms without causing electrolysis. Further investigation and development of the BE system should continue in both the medical and hygiene fields

    High-Performance Hybrid Supercapacitor Based on Graphene-Wrapped Li4Ti5O12 and Activated Carbon

    No full text
    Hybridizing battery and supercapacitor technologies have the potential to overcome the limitations of the currently prevailing energy-storage systems. Combining high-power capacitive electrodes from supercapacitors with the high-energy intercalation electrodes in lithium-ion batteries provides the opportunity to create a single device that can deliver both high energy and high power. Although energy densities in such hybrid systems easily exceed those found in supercapacitors, the kinetic imbalance between capacitive and intercalation electrodes remains a bottleneck to achieving the desired performance. This imbalance is eliminated through the use of graphene-wrapped Li4Ti5O12 from a simple, one-step process as a high-power anode in a new hybrid supercapacitor. The new hybrid supercapacitors are capable of delivering a high specific energy of up to 50 Whkg(-1) and can even maintain an energy of approximately 15 Whkg(-1) at a 20 s charge/discharge rate

    A highly sensitive and selective impedimetric aptasensor for interleukin-17 receptor A

    No full text
    Interleukin-17 receptor A (IL-17RA) has been recognized as a valuable biomarker for diverse diseases, including autoimmune diseases. In this work, an electrochemical biosensor with great sensitivity and selectivity toward IL-17RA was fabricated using an IL-17RA aptamer (K-d = 14.00 nM) for the first time. The aptasensor was manufactured using electrodeposition of gold nanoparticles, and then quantitative detection of IL-17RA was performed based on impedimetry. The developed sensor exhibited a superior analytical performance for IL-17RA with a wide dynamic range of 10-10,000 pg/mL in buffer and a detection limit of 2.13 pg/mL, which is lower than that of commercially available ELISA kits. In addition, we validated the high specificity of the designed aptasensor to only IL-17RA, which showed good sensitivity even in human serum solution. Furthermore, the detection of the differentiated HL-60 cells expressing 1L-17RA was successfully performed. Clinical applicability of the sensor was also demonstrated utilizing neutrophils separated from asthma patients. It is expected that the fabricated aptasensor will become an excellent diagnostic platform for IL-17RA-mediated diseases. (C) 2016 Elsevier B.V. All rights reserved.1166sciescopu

    Sparsentan in patients with IgA nephropathy: a prespecified interim analysis from a randomised, double-blind, active-controlled clinical trial

    No full text
    Background: Sparsentan is a novel, non-immunosuppressive, single-molecule, dual endothelin and angiotensin receptor antagonist being examined in an ongoing phase 3 trial in adults with IgA nephropathy. We report the prespecified interim analysis of the primary proteinuria efficacy endpoint, and safety. Methods: PROTECT is an international, randomised, double-blind, active-controlled study, being conducted in 134 clinical practice sites in 18 countries. The study examines sparsentan versus irbesartan in adults (aged ≥18 years) with biopsy-proven IgA nephropathy and proteinuria of 1·0 g/day or higher despite maximised renin-angiotensin system inhibitor treatment for at least 12 weeks. Participants were randomly assigned in a 1:1 ratio to receive sparsentan 400 mg once daily or irbesartan 300 mg once daily, stratified by estimated glomerular filtration rate at screening (30 to 1·75 g/day). The primary efficacy endpoint was change from baseline to week 36 in urine protein-creatinine ratio based on a 24-h urine sample, assessed using mixed model repeated measures. Treatment-emergent adverse events (TEAEs) were safety endpoints. All endpoints were examined in all participants who received at least one dose of randomised treatment. The study is ongoing and is registered with ClinicalTrials.gov, NCT03762850. Findings: Between Dec 20, 2018, and May 26, 2021, 404 participants were randomly assigned to sparsentan (n=202) or irbesartan (n=202) and received treatment. At week 36, the geometric least squares mean percent change from baseline in urine protein-creatinine ratio was statistically significantly greater in the sparsentan group (-49·8%) than the irbesartan group (-15·1%), resulting in a between-group relative reduction of 41% (least squares mean ratio=0·59; 95% CI 0·51-0·69; p<0·0001). TEAEs with sparsentan were similar to irbesartan. There were no cases of severe oedema, heart failure, hepatotoxicity, or oedema-related discontinuations. Bodyweight changes from baseline were not different between the sparsentan and irbesartan groups. Interpretation: Once-daily treatment with sparsentan produced meaningful reduction in proteinuria compared with irbesartan in adults with IgA nephropathy. Safety of sparsentan was similar to irbesartan. Future analyses after completion of the 2-year double-blind period will show whether these beneficial effects translate into a long-term nephroprotective potential of sparsentan. Funding: Travere Therapeutics

    Efficacy and safety of sparsentan versus irbesartan in patients with IgA nephropathy (PROTECT): 2-year results from a randomised, active-controlled, phase 3 trial

    No full text
    Background Sparsentan, a novel, non-immunosuppressive, single-molecule, dual endothelin angiotensin receptor antagonist, significantly reduced proteinuria versus irbesartan, an angiotensin II receptor blocker, at 36 weeks (primary endpoint) in patients with immunoglobulin A nephropathy in the phase 3 PROTECT trial's previously reported interim analysis. Here, we report kidney function and outcomes over 110 weeks from the double-blind final analysis. Methods PROTECT, a double-blind, randomised, active-controlled, phase 3 study, was done across 134 clinical practice sites in 18 countries throughout the Americas, Asia, and Europe. Patients aged 18 years or older with biopsy-proven primary IgA nephropathy and proteinuria of at least 1·0 g per day despite maximised renin–angiotensin system inhibition for at least 12 weeks were randomly assigned (1:1) to receive sparsentan (target dose 400 mg oral sparsentan once daily) or irbesartan (target dose 300 mg oral irbesartan once daily) based on a permuted-block randomisation method. The primary endpoint was proteinuria change between treatment groups at 36 weeks. Secondary endpoints included rate of change (slope) of the estimated glomerular filtration rate (eGFR), changes in proteinuria, a composite of kidney failure (confirmed 40% eGFR reduction, end-stage kidney disease, or all-cause mortality), and safety and tolerability up to 110 weeks from randomisation. Secondary efficacy outcomes were assessed in the full analysis set and safety was assessed in the safety set, both of which were defined as all patients who were randomly assigned and received at least one dose of randomly assigned study drug. This trial is registered with ClinicalTrials.gov, NCT03762850. Findings Between Dec 20, 2018, and May 26, 2021, 203 patients were randomly assigned to the sparsentan group and 203 to the irbesartan group. One patient from each group did not receive the study drug and was excluded from the efficacy and safety analyses (282 [70%] of 404 included patients were male and 272 [67%] were White) . Patients in the sparsentan group had a slower rate of eGFR decline than those in the irbesartan group. eGFR chronic 2-year slope (weeks 6–110) was −2·7 mL/min per 1·73 m2 per year versus −3·8 mL/min per 1·73 m2 per year (difference 1·1 mL/min per 1·73 m2 per year, 95% CI 0·1 to 2·1; p=0·037); total 2-year slope (day 1–week 110) was −2·9 mL/min per 1·73 m2 per year versus −3·9 mL/min per 1·73 m2 per year (difference 1·0 mL/min per 1·73 m2 per year, 95% CI −0·03 to 1·94; p=0·058). The significant reduction in proteinuria at 36 weeks with sparsentan was maintained throughout the study period; at 110 weeks, proteinuria, as determined by the change from baseline in urine protein-to-creatinine ratio, was 40% lower in the sparsentan group than in the irbesartan group (−42·8%, 95% CI −49·8 to −35·0, with sparsentan versus −4·4%, −15·8 to 8·7, with irbesartan; geometric least-squares mean ratio 0·60, 95% CI 0·50 to 0·72). The composite kidney failure endpoint was reached by 18 (9%) of 202 patients in the sparsentan group versus 26 (13%) of 202 patients in the irbesartan group (relative risk 0·7, 95% CI 0·4 to 1·2). Treatment-emergent adverse events were well balanced between sparsentan and irbesartan, with no new safety signals. Interpretation Over 110 weeks, treatment with sparsentan versus maximally titrated irbesartan in patients with IgA nephropathy resulted in significant reductions in proteinuria and preservation of kidney function.</p
    corecore