2 research outputs found

    Deposition of fine iron oxide particles in tap water using direct current electrophoretic deposition (EPD) technique / Syahira Mohd Sharif

    Get PDF
    An investigation of using electrophoretic deposition (EPD) technique to deposit negatively charge fine iron oxide particles in tap water samples on a counter charge electrode (anode) was conducted. Characterizations of fine iron oxide particles in tap water from two different locations i.e. commercial and residential areas, were identified. After centrifuging the tap water samples, particle analyzer was used to analyze particles sizes and zeta potential values. The average particle sizes for supernatant region from the commercial and residential areas were 230 ± 22.30 and 260 ± 3.68 nm respectively. The zeta potential value from residential area was higher than commercial area, i.e. -42.27 ± 0.12 and -34.83 ± 0.23 mV, respectively. X-Ray Diffraction (XRD) analysis indicated that the tap water samples consisted of iron oxide polymorphs, namely goethite (α-FeOOH), hematite (α-Fe₂O₃), magnetite (Fe₃O₄у), and maghemite (y- Fe₂O₃),). During the removal of fine iron oxide particles using EPD technique, direct current (DC) voltage was varied from 5 to 25 V at a constant electrode distance of 30 mm. Higher deposition of fine iron oxide particles was achieved using the carbon fibre electrode with a percentage removal of (96% ± 1.42) than using the carbon plate electrode (58% ± 2.17) at 5 V due to the greater surface area of the carbon fibre electrode. The percentage of fine iron oxide particle deposition decreased as the applied voltage increased from 5 to 25 V. High amount of bubbles were formed on electrodes during EPD technique due to electrolysis of water as the applied voltage increased. The percentage removal of Fe from tap water samples from both areas was higher than the removal of Fe from the synthesized iron oxide suspension due to high zeta potential values in the water samples after centrifugation (supernatant). EPD techniques also manage to remove other element (arsenic) in tap water samples which had adsorbed onto fine iron oxide particles with percentage removal 26% ± 1.05. EDX analysis confirmed that fine iron oxide particles were deposited on anode electrode. The results proved that EPD was effective to remove fine iron oxide particles and other element such as arsenic in tap water

    Electrophoretic deposition of adsorbed arsenic on fine iron oxide particles in tap water

    Get PDF
    Electrophoretic deposition (EPD) technique has been demonstrated to remove arsenic with natural adsorbent (fine iron oxide particles) in tap water samples. Characterizations of metal element particularly arsenic and fine iron oxide particles in tap water from two different locations, i.e. commercial and residential areas, were conducted. Results showed that the concentration of arsenic in tap water from residential area was higher than commercial area samples i.e. 0.022 ± 0.004 and 0.016 ± 0.008 ppm, respectively. The same finding was observed in zeta potential value where it was higher in the residential area than commercial area, i.e. −42.27 ± 0.12 and −34.83 ± 0.23 mV, respectively. During the removal of arsenic using the EPD technique, direct current (DC) voltage was varied from 5 to 25V at a constant electrode distance of 30 mm. Effect of zeta potential, voltage and electrode type were intensively investigated. High percentage removal of arsenic was obtained from carbon plate than carbon fibre electrode. The percentage removal of arsenic from all samples slightly decreased with increasing of the applied voltage. EDX analysis confirmed that arsenic has adsorbed onto deposited iron oxide particles on the anode electrode. Overall, EPD technique was found to be successful in removing arsenic onto fine iron oxide particles in tap water with 26% ± 1.05 of removal
    corecore