11,606 research outputs found

    Investigation of Complex Impedance and Modulus Properties of Nd Doped 0.5BiFeO3-0.5PbTiO3 Multiferroic Composites

    Full text link
    0.5BiNdxFe1-xO3-0.5PbTiO3 (x=0.05, 0.10, 0.15, 0.20) composites were successfully synthesized by a solid state reaction technique. At room temperature X-ray diffraction shows tetragonal structure for all concentrations of Nd doped 0.5BiFeO3-0.5PbTiO3 composites. The nature of Nyquist plot confirms the presence of bulk effects only for all compositions of Nd-doped 0.5BiFeO3-0.5PbTiO3 composites. The bulk resistance is found to decreases with the increasing in temperature as well as Nd concentration and exhibits a typical negative temperature coefficient of resistance (NTCR) behavior. Both the complex impedance and modulus studies have suggested the presence of non-Debye type of relaxation in the materials. Conductivity spectra reveal the presence of hopping mechanism in the electrical transport process of the materials. The activation energy of the composite increases with increasing Nd concentration and were found to be 0.28, 0.27, 0.31 and 0.32eV for x=0.05, 0.10, 0.15, 0.20 respectively at 200-275 oC for conduction process.Comment: 22 pages, 12 figures, 2 tables, 34 Referenc

    Lowest Order Second Harmonic Conversion in a Two-Level Gaseous System

    Get PDF

    Effect of Relaxation Parameters on the Performance of a Gas Laser

    Get PDF

    Rotational Analysis of the A-X System of Cul Molecule

    Get PDF

    Three different interlocking intramedullary nails for unstable reverse oblique inter-trochanteric fractures: a bio-mechanical comparative study

    Get PDF
    Background: Biomechanical testing, intramedullary devices have proven advantageous over the extramedullary devices in the management of unstable intertrochanteric fractures. Reverse oblique type of intertrochanteric fractures are highly unstable and intramedullary nails are currently the method of internal fixation. The currently available nails seems to provide rotational, axial and angular stability, but biomechanical analysis of the strain pattern in the bone and implant in this fractures are lacking. The aim of this experimental study was to analyse the strain in three different long femoral nail-bone units under physiological loading when implanted in Saw bone model after creating a reverse oblique intertrochanteric fracture.Methods: A total of 12 sawbones were divided in to 4 equal groups. Group 1 was intact saw bones and were used as controls. Group 2, Group 3 and Group 4 were implanted with Depuy, Stryker and Synthes nails respectively after creating a reverse oblique intertrochanteric fracture. All the four groups were axially loaded with 100 N increments until physiological loads. The strain patterns were measured at the posteromedial cortex and the peak strains were extracted at partial weight bearing i.e. 500 N and full weight bearing physiological loads i.e. 1000 N.Results: There was no significant difference in peak strains among the groups at partial loads. However at 1000 N loads the peak strain in the DePuy nail-bone unit was significantly high compared to the other two nail-bone units and the controls. Conclusions: These results question the safety of immediate full weight bearing following surgery when treating the reverse oblique unstable fractures with DePuy intramedullary nails. A period of partial weight bearing following fixation of reverse oblique fractures would be wise when using DePuy nails
    corecore