12 research outputs found

    Effects of Khat on Surface Roughness and Color of Feldspathic and Zirconia Porcelain Materials under Simulated Oral Cavity Conditions

    No full text
    Background and Objectives: Khat chewing is considered as a daily habit that is practiced by more than five million people globally. The effect of khat chewing on the surface roughness and the color stability of natural teeth and the material used in the fabrication of dental prosthesis remains unknown. This study was conducted to explore and compare the effect of khat homogenate (KH) on the surface roughness (Ra) and the average color changes (ΔE*) amongst natural teeth and selected shades from different porcelain types, namely, feldspathic metal ceramic (MC) VM13, computer-aided design/computer assisted manufacture (CAD/CAM) feldspathic (Vitablocs Mark II), and multilayer zirconia (Ceramill Zolid PS) porcelains. Materials and Methods: Seventy samples were prepared from natural teeth, feldspathic MC, CAD/CAM Vitablocs Mark II, and zirconia porcelain. The Ra values were measured using a profilometer and expressed in micrometers, whereas the ΔE* values were measured using VITA Easyshade® V spectrophotometer for all samples before and after frequent immersion and thermocycling in KH for 30 days. The surface topography was used to assess the materials surfaces (glazed or polished) after KH immersion by using a white light interferometry machine. Results: Results revealed that the Ra and the ΔE* values of the different types of tested porcelain were influenced by KH. The order of surface roughness values was glazed or polished MC > polished Zircon > polished Vitablocs Mark II > natural teeth. The lowest ΔE* values were recorded for glazed Vitablocs Mark II and MC, and the values could be arranged as polished zircon > natural teeth > glazed zircon > polished MC > polished Vitablocs Mark II. P values were significantly varied (<0.001) among all the tested groups, except the zircon group (>0.05) for both Ra and ΔE*. Conclusions: KH significantly affected both surface parameter and color of glazed or polished porcelain materials and natural teeth

    A Multidisciplinary Approach in the Treatment of Tempromandibular Joint Pain Associated with Qat Chewing

    Get PDF
    Pain of the tempro-mandibular joint (TMJ) has a direct bearing to missing teeth and excessive physical activity. Consumption of qat requires chewing on the leaves to extract their juice for long hours. A 65-year-old male Yemeni patient, a Qat chewer, reported to the university dental hospital at King Khalid University complaining of pain in left temporomandibular joint with missing mandibular anterior teeth. A multidisciplinary approach for the overall treatment of the patient was decided. Initial treatment was the relief of patient’s pain with the help of a night guard. This was followed by a fabrication of anterior FPD. The case was under maintenance and follow-up protocol for a period of 8 months with no complaint of pain discomfort

    Tooth Colored Post System: Review of Literature

    No full text
    The basic application of a tooth colored posts (functionally graded composite, zirconia and fiber reinforced composite) in the post endodontic restorative phase of a tooth is based on the usage of the correct post in a given situation. Many advantages of the tooth colored posts such as, its favorable esthetics, ease of use, their modulus of elasticity values that are similar to that of dentin and this can reduce the risk of fractures as well as stress concentration at the apex of root. It can increase their survival compared to teeth restored with metallic posts. The most complication of the colored post system is the deboning failures, but those posts allowed the retreatment of the deboning post. All studies evaluating the tooth colored post systems up to December 2011were included. Key words: Post, Tooth Colored, Endodontic Treated Teet

    Repairing of Fractured Metal Ceramic Restorations: Techniques Review

    No full text
    Abstract Statement of the problem: The ceramic veneer in Metal-ceramic crowns and FPDs have the potential for fracture. Fractured porcelain poses a serious and clinical problem. It may be desirable to repair a broken retainer of a fixed prosthesis rather than to remove it and risk the possibility of destroying the entire restoration or damaging the abutment teeth. Techniques: Intra-oral (re-bonding the fractured chip to the fixed restoration or using a composite resin to restore the fractured porcelain), Extra-oral (pin-retained casting, over-casting veneered with porcelain (for repair abutment or pontic), modified over casting or porcelain layer with resin adhesion, and Combination of intra and extra oral techniques. Conclusion: Ceramic repair techniques for fractured ceramic bridge should be consider as an alternative solution instead of replacing a new prosthesis which is coasty, harmful to the abutment teeth and long procedures. This article presents an over view of the different techniques used to repair the fractured porcelain from metal ceramic restoration or remaking of the fractured retainer from a multi-unite FPD.   Key words: Metal ceramic restoration, techniques repair, intraoral, extr oral &nbsp

    Replacement of multiunit joined porcelain fused to metal restoration with an esthetic separated all ceramic crowns: Clinical and technical report

    No full text
    Improper treatment plan, designing of the restorations and the selection of the restorative materials resulted in patient unsatisfactory. The purpose of this case is to create a hygienic and esthetic restoration for the patient with good social acceptance. Individual all ceramic zirconia crowns were fabricated for a 54-year-old male patient who attended the clinic with a multiunit joined porcelain fused to metal restoration. The esthetic treatment with all ceramic computer-aided design and computer-aided manufacturing crowns resulted in improved facial aesthetics; psychological status and social life of the patient. In addition to that, patient can practice standard oral hygiene in the present of separated crowns

    Oral Rehabilitation of Parkinson’s Disease Patient: A Review and Case Report

    Get PDF
    Parkinson’s disease is usually seen in adults in their middle and late ages. Most people with this disease are less likely to opt for dental treatments unless it is an acute condition. Tremors caused by Parkinson’s disease can make dental appointments, especially prolonged treatments, a challenge. The case presented here was successfully treated with an immediate denture for the partially edentulous maxillary and mandibular arches. Early morning brief appointments were given for the procedure. Patient was instructed to take the prescribed parkinsonism medications 60 to 90 minutes before the appointment to utilize the advantage of its peak response. Sympathetic and caring approach towards the patient was employed to reduce his anxiety during the procedures. Some modification of technics and materials was adopted to suit the special situation

    Physical, Optical, and Mechanical Properties of Ceramic Materials after Coffee Immersion and Evaluation of Cleaning Impact with Different Oral Hygiene Tools

    No full text
    This study aimed to evaluate the effect of three oral hygiene tools, a regular toothbrush, an electronic toothbrush, and mouthwash, on the color stability of three different computer-aided design (CAD) and computer-aided manufactured (CAM) ceramic blocks. Feldspathic ceramic (Vita Triluxe Forte), hybrid resin ceramic (Vita Enamic), and lithium disilicate glass-ceramic (IPS e.max CAD) were used in this study. A CAD/CAM system and 81 (27 of each material) samples of ceramic blocks were used. All samples were immersed in black coffee for 15 days, and the coffee was changed twice per day. Using a spectrophotometer probe, samples on a grey background were scanned, and physical properties like surface hardness and depth were measured using interferometry and a 3D non-contact surface metrology. After 30 days of application of oral hygiene tools, instruments were used to measure various physical, mechanical, and optical properties. Vita Triluxe had the highest average color variation values (ΔE00) after 15 and 30 days of immersion in coffee in both regular and electronic toothbrushes. Moreover, IPS e.max CAD had the least ΔE00 values with no significant differences among the groups. The surface roughness (Ra) of the Vita Enamic ceramic increased when using a regular toothbrush, and the surface height (Rz) for the Vita Enamic ceramic increased when an electronic toothbrush was used. IPS e.max CAD had the greatest modules of elasticity forces, and Vita Triluxe Forte had the lowest when used with a regular toothbrush. The ΔE00 values of the tested materials were minimally increased or decreased after 30 days of cleaning, and all were clinically acceptable. Ra and Rz were the highest for Vita Enamic in comparison to the other groups. The highest percentage in IPS e.max CAD was associated with a type 1 fracture, whereas type 3 was predominantly observed with Vita Enamic, and type 2 in the Vita Triluxe group without significant differences

    Bibliographic analysis and evaluation of the mesh keywords in the journal of prosthodontics: Implant, esthetic, and reconstructive dentistry

    No full text
    Background: Various studies have been conducted to analyze data via bibliometric analysis in different dentistry, including prosthetic dentistry. However, these studies evaluated the most cited published articles in dentistry. Objective: To analyze and evaluate the characteristic development of several mesh keywords in the Journal of Prosthodontics - Implant, Esthetic, and Reconstructive Dentistry between 1992 and 2022. Methods: The Scopus databases was searched to retrieve the data related to 8 categories, including published articles, most cited documents, authors and organizations, and maximum articles cited during the evaluation period. The data retrieved were exported to a Microsoft Excel sheet and were analyzed using the bibliometrix package. The data were first analyzed for ten years and then for 30 years. The highest of 10 were reported for each category, and co-authorship, reoccurrence, and linked data were also reported. Results: 2603 published documents were recorded from the Scopus databases. Articles comprised 87.9% of the total published work, followed by review articles at 5.46%. The most productive decade was between 2013 and 2022. 3793 terms were used during the evaluation period, with the maximum number in 2003-2012 (2481). A total of 5392 keywords were used during 1992-2022, with the highest number (3232) from 2013 to 2022. A total of 6108 authors were acknowledged, with the maximum number (3964) from 2013 to 2022 and the fewest (767) from 1992 to 2002. Authors from different countries increased from 17 countries in 1992-2002 to 52 countries in 2013-2022 (total = 63 countries). Similarly, the number of organizations increased from 312 organizations in 1992-2002 to 1315 organizations in 2013-2022 (total = 1976 organizations). Conclusion: The current bibliometric analysis delivered a comprehensive overview about more spread research topics and its impactful role in contemporary dentistry, especially prosthetic dentistry

    Assessment of Conventionally and Digitally Fabricated Complete Dentures: A Comprehensive Review

    No full text
    CAD/CAM technology is gaining popularity and replacing archaic conventional procedures for fabricating dentures. CAD/CAM supports using a digital workflow reduce the number of visits, chair time, and laboratory time, making it attractive to patients. This study aimed to provide a comparative review of complete dentures manufactured using CAD/CAM and conventional methods. The PubMed/Medline, Science Direct, Cochrane, and Google Scholar databases were searched for studies published in English within the last 11 years (from 2011 to 2021). The keywords used were “computer-engineered complete dentures”, “CAD/CAM complete dentures”, “computer-aided engineering complete dentures”, and “digital complete dentures”. The search yielded 102 articles. Eighteen relevant articles were included in this review. Overall, computer-engineered complete dentures have several advantages over conventional dentures. Patients reported greater satisfaction with computer-engineered complete dentures (CECDs) due to better fit, reduced chair time, shorter appointments, and fewer post-insertion visits. CAD/CAM allows for precision and reproducibility with fewer procedures compared to conventional dentures. Polymethyl methacrylate is used as the denture base material for conventional dentures. For CECDs, the resin can be modified and cross-linked to improve its mechanical properties. The advantages of CECDs include a reduced number of appointments, saving chairside time, a digital workflow allowing easy reproducibility and greater patient satisfaction with a better fit
    corecore