17 research outputs found
Pediatric intracranial dural arteriovenous fistulas: age-related differences in clinical features, angioarchitecture, and treatment outcomes.
OBJECTIVE Intracranial dural arteriovenous fistulas (DAVFs) are rare in children. This study sought to better characterize DAVF presentation, angioarchitecture, and treatment outcomes. METHODS Children with intracranial DAVFs between 1986 and 2013 were retrospectively identified from the neurointerventional database at the authors' institution. Demographics, clinical presentation, lesion angioarchitecture, treatment approaches, angiographic outcomes, and clinical outcomes were assessed. RESULTS DAVFs constituted 5.7% (22/423) of pediatric intracranial arteriovenous shunting lesions. Twelve boys and 10 girls presented between 1 day and 18 years of age; boys presented at a median of 1.3 years and girls presented at a median of 4.9 years. Four of 8 patients ≤ 1 year of age presented with congestive heart failure compared with 0/14 patients > 1 year of age (p = 0.01). Five of 8 patients ≤ 1 year old presented with respiratory distress compared with 0/14 patients > 1 year old (p = 0.0021). Ten of 14 patients > 1 year old presented with focal neurological deficits compared with 0/8 patients ≤ 1 year old (p = 0.0017). At initial angiography, 16 patients harbored a single intracranial DAVF and 6 patients had 2-6 DAVFs. Eight patients (38%) experienced DAVF obliteration by the end of treatment. Good clinical outcome (modified Rankin Scale score 0-2) was documented in 77% of patients > 1 year old at presentation compared with 57% of patients ≤ 1 year old at presentation. Six patients (27%) died. CONCLUSIONS Young children with DAVFs presented predominantly with cardiopulmonary symptoms, while older children presented with focal neurological deficits. Compared with other pediatric vascular shunts, DAVFs had lower rates of angiographic obliteration and poorer clinical outcomes
Spinal dural arteriovenous fistulas and intrathecal venous drainage: correlation between digital subtraction angiography, magnetic resonance imaging, and clinical findings
OBJECT: Spinal dural arteriovenous fistulas (SDAVFs) cause myelopathy through arterialization of the perimedullary venous plexus and venous congestion of the spinal cord. The authors hypothesized that the craniocaudal extent of engorgement of intrathecal draining veins between the fistula site and the point of drainage out of the thecal sac correlates with the degree of myelopathy. METHODS: A retrospective review of the authors\u27 institution\u27s radiology databases identified 31 patients with SDAVFs who had undergone digital subtraction angiography (DSA) and MRI examinations of the spine. The authors counted the number of vertebral body levels of spinal cord enhancement and intrathecal vessel enhancement on T1-weighted postcontrast MRI studies. They also counted the number of levels of cord hyperintensity and intrathecal flow voids on T2-weighted MRI studies. On DSA, the authors identified the number of vertebral body levels of dilated intrathecal draining veins and outflow points from intrathecal veins to epidural veins. Functional status of the patients at the time of diagnosis was assessed using the Aminoff-Logue scale (ALS). RESULTS: Enlargement of the intrathecal draining veins averaged 10 ± 7.7 spinal levels on DSA. Patients with enlarged draining veins extending 10 or more spinal levels on DSA had worse ALS scores (mean gait 3.4, mean micturition 1.5) than patients with draining veins extending fewer than 10 levels (mean gait 1.8, mean micturition 0.6; p = 0.009 and 0.02, respectively). The number of vertebral body levels of enlarged draining veins correlated with the ALS score (gait r = 0.42, p = 0.009; and micturition r = 0.55, p = 0.0006). More extensive enlarged draining veins were associated with more spinal cord T2 hyperintensity, T2 intrathecal flow voids, and T1 vessel enhancement but not cord enhancement. CONCLUSIONS: The craniocaudal extent of enlarged intrathecal veins draining SDAVF correlates with patient functional status, providing further insight into the pathophysiology of venous hypertensive myelopathy
Recommended from our members
Pediatric intracranial dural arteriovenous fistulas: age-related differences in clinical features, angioarchitecture, and treatment outcomes.
OBJECTIVE Intracranial dural arteriovenous fistulas (DAVFs) are rare in children. This study sought to better characterize DAVF presentation, angioarchitecture, and treatment outcomes. METHODS Children with intracranial DAVFs between 1986 and 2013 were retrospectively identified from the neurointerventional database at the authors' institution. Demographics, clinical presentation, lesion angioarchitecture, treatment approaches, angiographic outcomes, and clinical outcomes were assessed. RESULTS DAVFs constituted 5.7% (22/423) of pediatric intracranial arteriovenous shunting lesions. Twelve boys and 10 girls presented between 1 day and 18 years of age; boys presented at a median of 1.3 years and girls presented at a median of 4.9 years. Four of 8 patients ≤ 1 year of age presented with congestive heart failure compared with 0/14 patients > 1 year of age (p = 0.01). Five of 8 patients ≤ 1 year old presented with respiratory distress compared with 0/14 patients > 1 year old (p = 0.0021). Ten of 14 patients > 1 year old presented with focal neurological deficits compared with 0/8 patients ≤ 1 year old (p = 0.0017). At initial angiography, 16 patients harbored a single intracranial DAVF and 6 patients had 2-6 DAVFs. Eight patients (38%) experienced DAVF obliteration by the end of treatment. Good clinical outcome (modified Rankin Scale score 0-2) was documented in 77% of patients > 1 year old at presentation compared with 57% of patients ≤ 1 year old at presentation. Six patients (27%) died. CONCLUSIONS Young children with DAVFs presented predominantly with cardiopulmonary symptoms, while older children presented with focal neurological deficits. Compared with other pediatric vascular shunts, DAVFs had lower rates of angiographic obliteration and poorer clinical outcomes
Recommended from our members
New-Generation Laser-lithographed Dual-Axis Magnetically Assisted Remote-controlled Endovascular Catheter for Interventional MR Imaging: In Vitro Multiplanar Navigation at 1.5 T and 3 T versus X-ray Fluoroscopy.
PurposeTo assess the feasibility of multiplanar vascular navigation with a new magnetically assisted remote-controlled (MARC) catheter with real-time magnetic resonance (MR) imaging at 1.5 T and 3 T and to compare it with standard x-ray guidance in simulated endovascular catheterization procedures.Materials and methodsA 1.6-mm-diameter custom clinical-grade microcatheter prototype with lithographed double-saddle coils at the distal tip was deflected with real-time MR imaging. Two inexperienced operators and two experienced operators catheterized anteroposterior (celiac, superior mesenteric, and inferior mesenteric arteries) and mediolateral (renal arteries) branch vessels in a cryogel abdominal aortic phantom. This was repeated with conventional x-ray fluoroscopy by using clinical catheters and guidewires. Mean procedure times and percentage success data were analyzed with linear mixed-effects regression.ResultsThe MARC catheter tip was visible at 1.5 T and 3 T. Among inexperienced operators, MARC MR imaging guidance was not statistically different from x-ray guidance at 1.5 T (67% successful vessel selection turns with MR imaging vs 76% with x-ray guidance, P = .157) and at 3 T (75% successful turns with MR imaging vs 76% with x-ray guidance, P = .869). Experienced operators were more successful in catheterizing vessels with x-ray guidance (98% success within 60 seconds) than with 1.5-T (65%, P < .001) or 3-T (75%) MR imaging. Among inexperienced operators, mean procedure time was nearly equivalent by using MR imaging (31 seconds) and x-ray guidance (34 seconds, P = .436). Among experienced operators, catheterization was faster with x-ray guidance (20 seconds) compared with 1.5-T MR imaging (42 seconds, P < .001), but MARC guidance improved at 3 T (31 seconds). MARC MR imaging guidance at 3 T was not significantly different from x-ray guidance for the celiac (P = .755), superior mesenteric (P = .358), and inferior mesenteric (P = .065) arteries.ConclusionMultiplanar navigation with a new MARC catheter with real-time MR imaging at 1.5 T and 3 T is feasible and comparable to x-ray guidance for anteroposterior vessels at 3 T in a vascular phantom
New-Generation Laser-lithographed Dual-Axis Magnetically Assisted Remote-controlled Endovascular Catheter for Interventional MR Imaging: In Vitro Multiplanar Navigation at 1.5 T and 3 T versus X-ray Fluoroscopy
PURPOSE: To assess the feasibility of multiplanar vascular navigation with a new magnetically assisted remote-controlled (MARC) catheter with real-time magnetic resonance (MR) imaging at 1.5 T and 3 T and to compare it with standard x-ray guidance in simulated endovascular catheterization procedures. MATERIALS AND METHODS: A 1.6-mm–diameter custom clinical-grade microcatheter prototype with lithographed double-saddle coils at the distal tip was deflected with real-time MR imaging. Two inexperienced operators and two experienced operators catheterized anteroposterior (celiac, superior mesenteric, and inferior mesenteric arteries) and mediolateral (renal arteries) branch vessels in a cryogel abdominal aortic phantom. This was repeated with conventional x-ray fluoroscopy by using clinical catheters and guidewires. Mean procedure times and percentage success data were analyzed with linear mixed-effects regression. RESULTS: The MARC catheter tip was visible at 1.5 T and 3 T. Among inexperienced operators, MARC MR imaging guidance was not statistically different from x-ray guidance at 1.5 T (67% successful vessel selection turns with MR imaging vs 76% with x-ray guidance, P = .157) and at 3 T (75% successful turns with MR imaging vs 76% with x-ray guidance, P = .869). Experienced operators were more successful in catheterizing vessels with x-ray guidance (98% success within 60 seconds) than with 1.5-T (65%, P < .001) or 3-T (75%) MR imaging. Among inexperienced operators, mean procedure time was nearly equivalent by using MR imaging (31 seconds) and x-ray guidance (34 seconds, P = .436). Among experienced operators, catheterization was faster with x-ray guidance (20 seconds) compared with 1.5-T MR imaging (42 seconds, P < .001), but MARC guidance improved at 3 T (31 seconds). MARC MR imaging guidance at 3 T was not significantly different from x-ray guidance for the celiac (P = .755), superior mesenteric (P = .358), and inferior mesenteric (P = .065) arteries. CONCLUSION: Multiplanar navigation with a new MARC catheter with real-time MR imaging at 1.5 T and 3 T is feasible and comparable to x-ray guidance for anteroposterior vessels at 3 T in a vascular phantom. (©) RSNA, 2015 Online supplemental material is available for this article
Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.
To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA) and intravenous (IV) T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA) dural, internal carotid artery (ICA) dural, or pial. MR perfusion data regions of interest (ROIs) were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM), relative cerebral blood flow (rCBF), relative cerebral blood volume (rCBV), and mean transit time (MTT). Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11), ICA dural (n = 4), or pial (n = 3). FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion
Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging - Fig 1
<p>DSA in the lateral projection during injection of the right ECA (A) demonstrates vascular blush (black arrowheads) from a right frontal meningioma supplied by anterior division branches (white arrowheads) of the right middle meningeal artery (white arrow). DSA during injection of the right ICA (B) demonstrates vascular blush (black arrowheads) to the anteroinferior component of the tumor from pial branches (white arrowheads) of the frontopolar branch (white arrow) of the right anterior cerebral artery. Perfusion ROIs for dural (C) and pial (C) contributions to the tumor based on DSA findings.</p
IA vs. IV MR perfusion curve parameters by ROI.
<p>IA vs. IV MR perfusion curve parameters by ROI.</p