11 research outputs found

    Prevalence of ragweed allergy in rural Geneva - a pilot study.

    Get PDF
    OBJECTIVE: The prevalence of ragweed allergy is increasing worldwide. Ragweed distribution and abundance is spreading in Europe in a wide area ranging from the Rhone valley in France to Hungary and Ukraine, where the rate of the prevalence can peak at as high as 12%. Low-grade ragweed colonisation was seen in Geneva and Ticino, less than two decades ago. There were fears that allergies to ragweed would increase Switzerland. The intent of this study was to assess the rate of prevalence of sensitisation and allergy to ragweed in the population living in the first rural Swiss setting where ragweed had been identified in 1996, and to evaluate indirectly the efficacy of elimination and containment strategies. MATERIAL AND METHODS: In 2009, 35 adults in a rural village in the Canton of Geneva were recruited. Data were collected by means of questionnaires and skin-prick tests were done on each participant. The study was approved by the local Ethics Committee. RESULTS: Based on questionnaires, 48.6% had rhinitis (95% confidence interval [CI] 32.9-64.4; n = 17/35) and 17.1% asthma (95% CI 8.1-32.6; n = 6/35). Atopy was diagnosed in 26.4% (95% CI 12.9-44.4) of the sample (n = 9/34). Ragweed sensitisation was found in 2.9% (95% CI 0.7-19.7; n = 1/34), mugwort sensitisation in 2.9% (95% CI 0.1-14.9; n = 1/35), alder sensitisation in 17.1% (95% CI 6.6-33.6; n = 6/35), ash sensitisation in 12.5% (95% CI 3.5-29.0; n = 4/32) and grass sensitisation in 22.9% (95% CI 10.4-40.1; n = 8/35). Ragweed (95% CI 0.1-14.9; n = 1/34) and mugwort allergies (95% CI 0.1-14.9; n = 1/35) were both found in 2.9% of the population. CONCLUSION: This study showed a surprisingly low incidence of ragweed sensitisation and allergy, of 2.9% and 2.9%, respectively, 20 years after the first ragweed detection in Geneva. The feared rise in ragweed allergy seems not to have happened in Switzerland, compared with other ragweed colonised countries. These results strongly support early field strategies against ragweed

    Comparison of fundus autofluorescence images acquired by the confocal scanning laser ophthalmoscope (488nm excitation) and the modified Topcon fundus camera (580nm excitation)

    Get PDF
    To compare autofluorescence (AF) images obtained with the confocal scanning laser ophthalmoscope (using the Heidelberg retina angiograph; HRA) and the modified Topcon fundus camera, in a routine clinical setting. A prospective comparative study conducted at the Jules-Gonin Eye Hospital. Fifty-six patients from the medical retina clinic. All patients had complete ophthalmic slit-lamp and fundus examinations, colour and red-free fundus photography, AF imaging with both instruments, and fluorescein angiography. Cataract and fixation were graded clinically. AF patterns were analyzed for healthy and pathological features. Differences of image noise were analyzed by cataract grading and fixation. A total of 105 eyes were included. AF patterns discovered by the retina angiograph and the fundus camera images, respectively, were a dark optic disc in 72% versus 15%, a dark fovea in 92% versus 4%, sub- and intraretinal fluid visible as hyperautofluorescence on HRA images only, lipid exudates visible as hypoautofluorescence on HRA images only. The same autofluorescent pattern was found on both images for geographic atrophy, retinal pigment changes, drusen and haemorrhage. Image noise was significantly associated with the degree of cataract and/or poor fixation, favouring the fundus camera. Images acquired by the fundus camera before and after fluorescein angiography were identical. Fundus AF images differ according to the technical differences of the instruments used. Knowledge of these differences is important not only for correctly interpreting images, but also for selecting the most appropriate instrument for the clinical situatio

    New-Generation Multifocal Intraocular Lens for Pediatric Cataract.

    No full text
    Background/Aims: To evaluate multifocal intraocular lens (MIOL) implantation in children. Methods: This is a retrospective study evaluating refractive, visual and safety results of MIOL in pediatric cataract surgery. Average follow-up was 25.73 ± 10.5 months. Surgery included 12 o'clock clear corneal incision, anterior capsulorhexis, lens material aspiration and MIOL implantation (SN6AD3; Alcon). Results: We included 34 cataract eyes of 26 pediatric patients aged 2-15 years, of which 14 (54%) were unilateral. Best near visual acuity (BNVA) and best distance visual acuity (BDVA) improved significantly in 100% of eyes (p = 0.0001). BDVA was above 0.8 in 31.25% (5/16) of bilateral cases. Significant stereopsis improvement was observed postoperatively in bilateral cases only (p = 0.01). Conclusion: MIOL implantation is a safe alternative to monofocal pseudophakia for pediatric cataract with a very low complication rate. Significant BNVA, BDVA and stereopsis improvement can be achieved, particularly in bilateral cases. Message: This study shows significant BDVA, BNVA and stereopsis improvement, especially in bilateral cases, after MIOL implantation for pediatric cataracts. © 2013 S. Karger AG, Basel

    Prevalence of ragweed allergy in rural Geneva – a pilot study

    No full text

    Wechsel von einem mechanischen Mikrokeratom auf einen Femtosekunden-Laser zur Korrektur von Astigmatismus mittels LASIK: klinische Ergebnisse einer retrospektiven, konsekutiven Vergleichsstudie Moving from a Mechanical Microkeratome to a Femtosecond Laser for LASIK to Correct Astigmatic Patients: Clinical Outcomes of a Retrospective, Consecutive, Comparative Study.

    No full text
    Background: To evaluate outcomes after optimized laser in situ keratomileusis (LASIK) for astigmatism correction with flap created by a mechanical microkeratome or a femtosecond laser. Patients and Methods: In this retrospective study, a total of 102 eyes of 71 consecutive patients were enrolled undergoing optimized LASIK treatments using the Allegretto laser system (WaveLight Laser Technologie AG, Erlangen, Germany). A mechanical microkeratome for flap creation was used (One Use, Moria®) in 46 eyes (31 patients, spherical equivalent [SE] -4.44 D ± 2.4) and a femtosecond laser was used (LDV, Ziemer®) in 56 eyes (40 patients, spherical equivalent [SE] -3.07 D ± 3.3). The two groups were matched for inclusion criteria and were operated under similar conditions by the same surgeon. Results: Overall, the preoperative spherical equivalent was -9.5 diopters (D) to +3.37 D; the preoperative manifest astigmatism was between -1.5 D and -3.5 D. At 6 months postoperatively, the mean postoperative uncorrected distance visual acuity (UDVA) was 0.93 ± 0.17 (range 0.4 to 1.2) in the Moria group and 1.0 ± 0.21 (range 0.6 to 1.6) in the Femto group, which was statistically significant (p = 0.003). Comparing the cylinder power there was a statistical difference between the two groups (p = 0.0015). Conclusions: This study shows that the method of flap creation has a significant impact on postoperative astigmatism with a significantly better postoperative UDVA in the Femto group. These findings suggest that the femtosecond laser provides a better platform for LASIK treatment of astigmatism than the commonly used microkeratome

    Comparison of fundus autofluorescence images acquired by the confocal scanning laser ophthalmoscope (488 nm excitation) and the modified Topcon fundus camera (580 nm excitation).

    Get PDF
    To compare autofluorescence (AF) images obtained with the confocal scanning laser ophthalmoscope (using the Heidelberg retina angiograph; HRA) and the modified Topcon fundus camera, in a routine clinical setting. A prospective comparative study conducted at the Jules-Gonin Eye Hospital. Fifty-six patients from the medical retina clinic. All patients had complete ophthalmic slit-lamp and fundus examinations, colour and red-free fundus photography, AF imaging with both instruments, and fluorescein angiography. Cataract and fixation were graded clinically. AF patterns were analyzed for healthy and pathological features. Differences of image noise were analyzed by cataract grading and fixation. A total of 105 eyes were included. AF patterns discovered by the retina angiograph and the fundus camera images, respectively, were a dark optic disc in 72 % versus 15 %, a dark fovea in 92 % versus 4 %, sub- and intraretinal fluid visible as hyperautofluorescence on HRA images only, lipid exudates visible as hypoautofluorescence on HRA images only. The same autofluorescent pattern was found on both images for geographic atrophy, retinal pigment changes, drusen and haemorrhage. Image noise was significantly associated with the degree of cataract and/or poor fixation, favouring the fundus camera. Images acquired by the fundus camera before and after fluorescein angiography were identical. Fundus AF images differ according to the technical differences of the instruments used. Knowledge of these differences is important not only for correctly interpreting images, but also for selecting the most appropriate instrument for the clinical situation
    corecore