434 research outputs found

    Automotive Bankruptcy Panel Discussion - November 16, 2009

    Get PDF
    This panel discussion concerning bankruptcy and the automobile industry took place in the Joseph W. Bartunek III Moot Court Room on the campus of the Cleveland-Marshall College of Law on November 16, 2009

    Normothermic machine perfusion of ischaemically damaged porcine kidneys with autologous, allogeneic porcine and human red blood cells

    Get PDF
    In porcine kidney auto-transplant models, red blood cells (RBCs) are required for ex-vivo normothermic machine perfusion (NMP). As large quantities of RBCs are needed for NMP, utilising autologous RBCs would imply lethal exsanguination of the pig that is donor and recipient-to-be in the same experiment. The purpose of this study was to determine if an isolated porcine kidney can also be perfused with allogeneic porcine or human RBCs instead. Porcine kidneys, autologous and allogeneic blood were obtained from a local slaughterhouse. Human RBCs (O-pos), were provided by our transfusion laboratory. Warm ischaemia time was standardised at 20 minutes and subsequent hypothermic machine perfusion lasted 1.5–2.5 hours. Next, kidneys underwent NMP at 37°C during 7 hours with Williams’ Medium E and washed, leukocyte depleted RBCs of either autologous, allogeneic, or human origin (n = 5 per group). During perfusion all kidneys were functional and produced urine. No macroscopic adverse reactions were observed. Creatinine clearance during NMP was significantly higher in the human RBC group in comparison with the allogeneic group (P = 0.049) but not compared to the autologous group. The concentration of albumin in the urine was significantly higher in the human RBC group (P <0.001) compared to the autologous and allogeneic RBC group. Injury marker aspartate aminotransferase was significantly higher in the human RBC group in comparison with the allogeneic group (P = 0.040) but not in comparison with the autologous group. Renal histology revealed glomerular and tubular damage in all groups. Signs of pathological hyperfiltration and microvascular injury were only observed in the human RBC group. In conclusion, perfusion of porcine kidneys with RBCs of different origin proved technically feasible. However, laboratory analysis and histology revealed more damage in the human RBC group compared to the other two groups. These results indicate that the use of allogeneic RBCs is preferable to human RBCs in a situation where autologous RBCs cannot be used for NMP

    Introduction of the Grayscale Median for Ultrasound Tissue Characterization of the Transplanted Kidney

    Get PDF
    Ultrasound examination is advised for early post-kidney transplant assessment. Grayscale median (GSM) quantification is novel in the kidney transplant field, with no systematic assessment previously reported. In this prospective cohort study, we measured the post-operative GSM in a large cohort of adult kidney transplant recipients (KTR) who consecutively underwent Doppler ultrasound directly after transplantation (within 24 h), compared it with GSM in nontransplanted patients, and investigated its association with baseline and follow-up characteristics. B-mode images were used to calculate the GSM in KTR and compared with GSM data in nontransplanted patients, as simulated from summary statistics of the literature using a Mersenne twister algorithm. The association of GSM with baseline and 1-year follow-up characteristics were studied by means of linear regression analyses. In 282 KTR (54 ± 15 years old, 60% male), the median (IQR) GSM was 55 (45-69), ranging from 22 to 124 (coefficient of variation = 7.4%), without differences by type of donation (p = 0.28). GSM in KTR was significantly higher than in nontransplanted patients (p < 0.001), and associated with systolic blood pressure, history of cardiovascular disease, and donor age (std. β = 0.12, -0.20, and 0.13, respectively; p < 0.05 for all). Higher early post-kidney transplant GSM was not associated with 1-year post-kidney transplant function parameters (e.g., measured and estimated glomerular filtration rate). The data provided in this study could be used as first step for further research on the application of early postoperative ultrasound in KTR

    Prolonged ex-vivo normothermic kidney perfusion:The impact of perfusate composition

    Get PDF
    Normothermic machine perfusion (NMP) of donor kidneys provides the opportunity for improved graft preservation and objective pre-transplant ex-vivo organ assessment. Currently, a multitude of perfusion solutions exist for renal NMP. This study aimed to evaluate four different perfusion solutions side-by-side and determine the influence of different perfusate compositions on measured renal perfusion parameters. Porcine kidneys and blood were obtained from a slaughterhouse. Kidneys underwent NMP at 37°C for 7 hours, with 4 different perfusion solutions (n = 5 per group). Group 1 consisted of red blood cells (RBCs) and a perfusion solution based on Williams' Medium E. Group 2 consisted of RBCs, albumin and a balanced electrolyte composition. Group 3 contained RBCs and a medium based on a British clinical NMP solution. Group 4 contained RBCs and a medium used in 24-hour perfusion experiments. NMP flow patterns for solutions 1 and 2 were similar, solutions 3 and 4 showed lower but more stable flow rates. Thiobarbituric acid reactive substances were significantly higher in solution 1 and 4 compared to the other groups. Levels of injury marker N-acetyl-β-D glucosaminidase were significantly lower in solution 2 in comparison with solution 3 and 4. This study illustrates that the perfusate composition during NMP significantly impacts the measured perfusion and injury parameters and thus affects the interpretation of potential viability markers. Further research is required to investigate the individual influences of principal perfusate components to determine the most optimal conditions during NMP and eventually develop universal organ assessment criteria
    • …