81 research outputs found

    Development of a handy oil-skimmer

    Get PDF
    金沢大学大学院自然科学研究科環境創成金沢大学工学部Recently marine-pollution by high-viscous oil leaked from wrecked ships has been becoming a remarkable problem in the world. Japan government is renewing old oil recovery vessels with new concept. The oil recovery vessels are available on the open sea, but unworkable in a narrow space. We have developed a handy oil recovery system which is portable and used for supplementing the weak point of the oil recovery vessel. The system consists of a water jet oil-skimmer and a gravity oil/water separator. The oil skimmer has a high-pressure water jet pump inside the suction mouth and a long shaft which is used as a conduit of the recovered fluid as well as a spring-hanging device which enables an operator to easily manipulate it from the deck of the ship. After 3-year research and experiments, we have completed the system successfully. The system will be soon installed on our oil recovery vessels. © 2004 IEEE

    Dual-optical-comb spectroscopic ellipsometry

    Full text link
    Spectroscopic ellipsometry is a means to investigate optical and dielectric material responses. Conventional spectroscopic ellipsometry has trade-offs between spectral accuracy, resolution, and measurement time. Polarization modulation has afforded poor performance due to its sensitivity to mechanical vibrational noise, thermal instability, and polarization wavelength dependency. We equip a spectroscopic ellipsometer with dual-optical-comb spectroscopy, viz. dual-optical-comb spectroscopic ellipsometry (DCSE). The DCSE directly and simultaneously obtains amplitude and phase information with ultra-high spectral precision that is beyond the conventional limit. This precision is due to the automatic time-sweeping acquisition of the interferogram using Fourier transform spectroscopy and optical combs with well-defined frequency. Ellipsometric evaluation without polarization modulation also enhances the stability and robustness of the system. In this study, we evaluate the DCSE of birefringent materials and thin films, which showed improved spectral accuracy and a resolution of up to 1.2x10-5 nm across a 5-10 THz spectral bandwidth without any mechanical movement.Comment: 30 pages, 4 figure

    Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines

    Get PDF
    The prevention of nosocomial infections is an imperative task. The dental chair unit (DCU) is an indispensable device used in dental treatment. However, it is known that the dental unit water line (DUWL) can become contaminated with biofilm, consisting mainly of heterotrophic bacteria (HB). Recently, the International Organization for Standardization specified the methods for testing DUWL contamination management. On these grounds, a simulator reproducing DUWL was prepared to standardize the examination method of the DUWL contamination. Objectives To evaluate the reproducibility of the DUWL simulator, monitor the DUWL contamination states, and test the efficacy of a commercial decontaminant for DUWL. Methods The DUWL simulator was assembled by a DCU manufacturing company. The simulator's DUWL was filled with tap water (TW), and left for approximately one year. Neutral electrolyzed water (NEW) was used as a decontaminant for DUWL. Both TW and NEW were passed through DUWL in a timely manner simulating daily dental treatment. Water was sampled from the air turbine hand piece weekly for 4 weeks and used for HB culture. Contamination status was evaluated by measuring bacterial adenosine triphosphate release and by culturing on Reasoner's 2A medium. Results The DUWL released contaminated water had a bacterial count of over 6 × 104 cfu/mL. After passing NEW through DUWL for 1 week, the count drastically decreased to its basal level and remained steady for 4 weeks. However, TW showed no effect on DUWL decontamination throughout the examination periods. Conclusions The DUWL simulator could be useful to examine the efficacy of the decontaminant for DUWL and development of new methods in DUWL contamination management

    Adaptive sampling dual terahertz comb spectroscopy using dual free-running femtosecond lasers

    Get PDF
    Terahertz (THz) dual comb spectroscopy (DCS) is a promising method for high-accuracy, high-resolution, broadband THz spectroscopy because the mode-resolved THz comb spectrum includes both broadband THz radiation and narrow-line CW-THz radiation characteristics. In addition, all frequency modes of a THz comb can be phase-locked to a microwave frequency standard, providing excellent traceability. However, the need for stabilization of dual femtosecond lasers has often hindered its wide use. To overcome this limitation, here we have demonstrated adaptive-sampling THz-DCS, allowing the use of free-running femtosecond lasers. To correct the fluctuation of the time and frequency scales caused by the laser timing jitter, an adaptive sampling clock is generated by dual THz-comb-referenced spectrum analysers and is used for a timing clock signal in a data acquisition board. The results not only indicated the successful implementation of THz-DCS with free-running lasers but also showed that this configuration outperforms standard THz-DCS with stabilized lasers due to the slight jitter remained in the stabilized lasers

    General characterization of Antarctic micrometeorites collected by the 39th Japanese Antarctic Research Expedition: Consortium studies of JARE AMMs (III)

    Get PDF
    From November 1998 to January 1999,the 39th Japanese Antarctic Research Expedition (JARE-39) undertook Japanese first large-scale collection of Antarctic micrometeorites (AMMs), with sizes larger than 10μm, at the Meteorite Ice Field around the Yamato Mountains in Antarctica (at three different locations, for a total of 24 collection sites). The number of collected AMMs larger than 40μm is estimated to be about 5000. Here we present the general characterization (i.e., micro-morphology and surface chemical composition using SEM/EDS) of ∿810 AMMs chosen from 5 of the 24 sites. Additionally, the mineral composition of 61 out of 810 AMMs was determined by Synchrotron X-ray radiation. Preliminary results on mineralogical and chemical compositions show similarities with that of previous studies, even though a pronounced alteration of some AMMs is noticed. A correlation is found between the Mg/Si ratio at the sample\u27s surfaces of unmelted AMMs and the age of snow/ice in which the AMMs are embedded

    Molecular cloning of doublesex genes of four cladocera (water flea) species

    Get PDF
    BACKGROUND: The gene doublesex (dsx) is known as a key factor regulating genetic sex determination in many organisms. We previously identified two dsx genes (DapmaDsx1 and DapmaDsx2) from a freshwater branchiopod crustacean, Daphnia magna, which are expressed in males but not in females. D. magna produces males by parthenogenesis in response to environmental cues (environmental sex determination) and we showed that DapmaDsx1 expression during embryonic stages is responsible for the male trait development. The D. magna dsx genes are thought to have arisen by a cladoceran-specific duplication; therefore, to investigate evolutionary conservation of sex specific expression of dsx genes and to further assess their functions in the environmental sex determination, we searched for dsx homologs in four closely related cladoceran species. RESULTS: We identified homologs of both dsx genes from, D. pulex, D. galeata, and Ceriodaphnia dubia, yet only a single dsx gene was found from Moina macrocopa. The deduced amino acid sequences of all 9 dsx homologs contained the DM and oligomerization domains, which are characteristic for all arthropod DSX family members. Molecular phylogenetic analysis suggested that the dsx gene duplication likely occurred prior to the divergence of these cladoceran species, because that of the giant tiger prawn Penaeus monodon is rooted ancestrally to both DSX1 and DSX2 of cladocerans. Therefore, this result also suggested that M. macrocopa lost dsx2 gene secondarily. Furthermore, all dsx genes identified in this study showed male-biased expression levels, yet only half of the putative 5’ upstream regulatory elements are preserved in D. magna and D. pulex. CONCLUSIONS: The all dsx genes of five cladoceran species examined had similar amino acid structure containing highly conserved DM and oligomerization domains, and exhibited sexually dimorphic expression patterns, suggesting that these genes may have similar functions for environmental sex determination in cladocerans

    Dual-comb spectroscopic ellipsometry

    Get PDF
    Spectroscopic ellipsometry is a means of investigating optical and dielectric material responses. Conventional spectroscopic ellipsometry is subject to trade-offs between spectral accuracy, resolution, and measurement time. Polarization modulation has afforded poor performance because of its sensitivity to mechanical vibrational noise, thermal instability, and polarization-wavelength dependency. We combine spectroscopic ellipsometry with dual-comb spectroscopy, namely, dual-comb spectroscopic ellipsometry. Dual-comb spectroscopic ellipsometry (DCSE). DCSE directly and simultaneously obtains the ellipsometric parameters of the amplitude ratio and phase difference between s-polarized and p-polarized light signals with ultra-high spectral resolution and no polarization modulation, beyond the conventional limit. Ellipsometric evaluation without polarization modulation also enhances the stability and robustness of the system. In this study, we construct a polarization-modulation-free DCSE system with a spectral resolution of up to 1.2 × 10−5 nm throughout the spectral range of 1514–1595 nm and achieved an accuracy of 38.4 nm and a precision of 3.3 nm in the measurement of thin-film samples
    corecore