783 research outputs found

    Tokyo Axion Helioscope

    Full text link
    A new search result of the Tokyo axion helioscope is presented. The axion helioscope consists of a dedicated cryogen-free 4T superconducting magnet with an effective length of 2.3 m and PIN photodiodes as x-ray detectors. Solar axions, if exist, would be converted into X-ray photons through the inverse Primakoff process in the magnetic field. Conversion is coherently enhanced even for massive axions by filling the conversion region with helium gas. The present third phase measurement sets a new limit of g_{a\gamma\gamma}<(5.6--13.4)\times10^{-10} GeV^{-1} for the axion mass of 0.84<m_a<1.0 eV at 95% confidence level.Comment: 4th Patras Workshop on Axions, WIMPs and WISP

    Optical isolator for TE polarized light realized by adhesive bonding of Ce:YIG on silicon-on-insulator waveguide circuits

    Get PDF
    An optical isolator for transverse electric (TE) polarized light is demonstrated by adhesive bonding of a ferrimagnetic garnet die on top of a 380 nm thick silicon waveguide circuit. Polarization rotators are implemented in the arms of a nonreciprocal Mach-Zehnder interferometer to rotate the polarization to transverse magnetic in the nonreciprocal phase shifter regions. Calculation of the nonreciprocal phase shift (NRPS) as a function of bonding layer thickness experienced by the TM mode in the interferometer arms is presented, together with the simulation of the robustness of the polarization rotator. Experimentally, 32 dB isolation is measured at 1540.5 nm wavelength using a magnetic field transverse to the light propagation directions. This paves the way to the cointegration of laser diodes and optical isolators on a silicon photonics platform

    Search for Hidden photons with Sumico

    Full text link
    We searched for solar hidden photons in the visible photon energy range using a hidden photon detector add-on attached to Sumico. It consists of a parabolic mirror of dia. 0.5m and f=1m installed in a vacuum chamber, and a low noise photomultiplier tube at the focal point. No evidence for the existence of hidden photons was found in the latest measurement giving a new limit on the photon-hidden photon mixing parameter in the hidden photon mass range 0.001-1eV.Comment: 6 pages. Contributed to the 9th Patras Workshop on Axions, WIMPs and WISPs, Mainz, June 24-28, 201

    EAS development curve at energy of 10(16) - 10(18) eV measured by optical Cerenkov light

    Get PDF
    The data of optical Cerenkov light from extensive air shower observed at the core distance more than 1 Km at Akeno are reexamined. Applying the new simulated results, the shower development curves for the individual events were constructed. For the showers of 10 to 17th power eV the average depth at the shower maximum is determined to be 660 + or - 40 gcm/2. The shower curve of average development is found to be well described by a Gaisser-Hillas shower development function with above shower maximum depth

    Surgical Results of Patients with Peritoneal Carcinomatosis Treated with Cytoreductive Surgery Using a New Technique Named Aqua Dissection

    Get PDF
    During 2004 to 2011, 81, 420, and 166 patients with colorectal cancer (CRC), epithelial appendiceal neoplasm (APN), and gastric cancer (GC) with PC were treated with cytoreductive surgery (CRS) plus perioperative chemotherapy. CRS was performed by peritonectomy techniques using an aqua dissection. Results. Complete cytoreduction was done in 62/81 (76.5%), 228/420 (54.3%), and 101/166 (60.8%) of patients with CRC, APN, and GC. The main reasons of incomplete resections were involvement of all peritoneal regions and diffuse involvement of small bowel. The incidence (64%, 302/470) of CC-0 resection after introduction of an aqua dissection was significantly higher than before (42%, 82/197). A total of 41 (6.1%) patients died postoperatively. Major complication (grade 3-4 complications) occurred in 126 patients (18.9%). A reoperation was necessary in 36 patients (5.4%). By the multivariate analysis, PCI scores capable of serving as thresholds for favorable versus poor prognosis in each group and CC scores demonstrated as the independent prognostic factors. Conclusions. Peritonectomy using an aqua dissection improves the incidence of complete cytoreduction, and improves the survival of patients with PC. Patients with PCI larger than the threshold values should be treated with chemotherapy to improve the incidences of complete cytoreduction
    corecore