18 research outputs found

    Comparison of surgical outcomes between iStent inject W implantation and microhook ab interno trabeculotomy in combination with phacoemulsification in primary open-angle glaucoma patients

    Get PDF
    PurposeTo examine primary open-angle glaucoma patients after undergoing combined cataract surgery with microhook ab interno trabeculotomy (μLOT-Phaco) or iStent inject W implantation (iStent-Phaco), and then evaluate the surgical outcomes after a minimum of 6 months of follow-up.MethodsBetween October 2020 and July 2022, 39 μLOT-Phaco eyes and 55 iStent-Phaco eyes that underwent surgery were evaluated in this retrospective, multicenter comparative case series. Data that included preoperative and postoperative intraocular pressure (IOP), number of glaucoma medications, and occurrence of complications were collected from medical records and then examined. Surgical failure was defined as patients exhibiting a < 20% reduction in the preoperative IOP or an IOP > 18 mmHg on two consecutive follow-up visits, or when patients were required to undergo reoperation. Success rates were determined based on a Kaplan–Meier survival analysis.ResultsAt 3, 6 and 12 months postoperatively, there was a significant postoperative reduction in the IOP (p < 0.001) and in the medications scores (p < 0.001) for both of the groups. In the μLOT-Phaco and iStent-Phaco groups, the probabilities of success at 6 and 12 months were 55.3 and 45.5%, and 48.4 and 45.5% (p = 0.38; log-rank test), respectively. In the iStent-Phaco group, there was a significant decrease in the hyphema.ConclusionComparable surgical outcomes occurred for both the μLOT and iStent inject W procedures

    Validating Variational Bayes Linear Regression Method With Multi-Central Datasets.

    Get PDF
    PurposeTo validate the prediction accuracy of variational Bayes linear regression (VBLR) with two datasets external to the training dataset.MethodThe training dataset consisted of 7268 eyes of 4278 subjects from the University of Tokyo Hospital. The Japanese Archive of Multicentral Databases in Glaucoma (JAMDIG) dataset consisted of 271 eyes of 177 patients, and the Diagnostic Innovations in Glaucoma Study (DIGS) dataset includes 248 eyes of 173 patients, which were used for validation. Prediction accuracy was compared between the VBLR and ordinary least squared linear regression (OLSLR). First, OLSLR and VBLR were carried out using total deviation (TD) values at each of the 52 test points from the second to fourth visual fields (VFs) (VF2-4) to 2nd to 10th VF (VF2-10) of each patient in JAMDIG and DIGS datasets, and the TD values of the 11th VF test were predicted every time. The predictive accuracy of each method was compared through the root mean squared error (RMSE) statistic.ResultsOLSLR RMSEs with the JAMDIG and DIGS datasets were between 31 and 4.3 dB, and between 19.5 and 3.9 dB. On the other hand, VBLR RMSEs with JAMDIG and DIGS datasets were between 5.0 and 3.7, and between 4.6 and 3.6 dB. There was statistically significant difference between VBLR and OLSLR for both datasets at every series (VF2-4 to VF2-10) (P < 0.01 for all tests). However, there was no statistically significant difference in VBLR RMSEs between JAMDIG and DIGS datasets at any series of VFs (VF2-2 to VF2-10) (P > 0.05).ConclusionsVBLR outperformed OLSLR to predict future VF progression, and the VBLR has a potential to be a helpful tool at clinical settings

    Changes in Anterior Segment Morphology of Iris Bombe before and after Laser Peripheral Iridotomy in Patients with Uveitic Secondary Glaucoma

    Get PDF
    Purpose. To quantify changes in anterior segment (AS) parameters after laser peripheral iridotomy (LPI) using AS-optical coherence tomography (OCT) of iris bombe. Method. AS images of eight eyes were captured before and after iris bombe and more than 2 weeks after LPI (post-LPI) using AS-OCT. We compared the following AS parameters: anterior chamber depth (ACD), anterior chamber volume (ACV), iris curvature (IC), iris thickness at 500 μm from the scleral spur (IT-1) in the middle between the iris root and pupillary margin (IT-2) and 500 μm from the pupillary margin (IT-3) to the anterior chamber angle (ACA) (angle opening distance [AOD750]), and trabecular iris space area. Results. Mean IT-1 and IT-3, but not IT-2, were lower after iris bombe (IT-1, P=0.001; IT-2, P=0.081; and IT-3, P=0.001). There were no significant differences between ACD at pre-LPI and before iris bombe (P=0.096). The mean ACV and AOD750 of iris bombe increased at post-LPI (ACV, P<0.01, and AOD750, P<0.05). The mean IT-1, IT-2, and IT-3 increased at post-LPI (all, P≤0.01). IC decreased at post-LPI (P<0.001), and ACD at post-LPI did not change. Conclusions. The iris extends and becomes thinner during iris bombe. LPI during bombe decreases the IC and increases the ACV and ACA

    Intraobserver and interobserver agreement among anterior chamber angle evaluations using automated 360-degree gonio-photos.

    No full text
    PurposeTo investigate the reproducibility for the iridocorneal angle evaluations using the pictures obtained by a gonioscopic camera, Gonioscope GS-1 (Nidek Co., Gamagori, Japan).MethodsThe pragmatic within-patient comparative diagnostic evaluations for 140 GS-1 gonio-images obtained from 35 eyes of 35 patients at four ocular sectors (superior, temporal, inferior, and nasal angles) were conducted by five independent ophthalmologists including three glaucoma specialists in a masked fashion twice, 1 week apart. We undertook the observer agreement and correlation analyses of Scheie's angle width and pigmentation gradings and detection of peripheral anterior synechia and Sampaolesi line.ResultsThe respective Fleiss' kappa values for the four elements between manual gonioscopy and automated gonioscope by the glaucoma specialist were 0.22, 0.40, 0.32 and 0.58. Additionally, the respective intraobserver agreements for the four elements by the glaucoma specialist each were 0.32 to 0.65, 0.24 to 0.71, 0.35 to 0.70, and 0.20 to 0.76; the Fleiss' kappa coefficients for the four elements among the three glaucoma specialists were, respectively, 0.31, 0.38, 0.31, and 0.17; the Fleiss' kappa coefficients for the angle width and pigmentation gradings between the two glaucoma specialists each were 0.30 to 0.35, and 0.29 to 0.43, respectively. Overall, the Kendall's tau coefficients for the angle gradings reflected the positive correlations in the evaluations.ConclusionOur findings suggested slight-to-substantial intraobserver agreement and slight-to-fair (among the three) or fair-to-moderate (between the two each) interobserver agreement for the angle assessments using GS-1 gonio-photos even by glaucoma specialists. Sufficient training and a solid consensus should allow us to perform more reliable angle assessments using gonio-photos with high reproducibility

    Factors affecting eye drop instillation in glaucoma patients with visual field defect.

    No full text
    To investigate the success rate of eye drop instillation in glaucoma patients with visual field defect as well as non-glaucoma volunteers. Factors that may affect the success rate of eye drop instillation were also evaluated.A prospective, observational study.Seventy-eight glaucoma patients and 85 non-glaucoma volunteers were recruited in this study.Open angle glaucoma patients with visual field defect as well as non-glaucoma volunteers were asked to video record their procedures of eye drop instillation using a 5-mL plastic bottle of artificial tear solution. Success of eye drop instillation was judged on video based on the first one drop of solution successfully applied on the cornea, by two investigators.Success rate of eye drop instillation in glaucoma patients and non-glaucoma volunteers. Factors related to success rate of eye drop instillation, such as visual field defect and clinical characteristics, were also analyzed using multivariable logistic regression.No significant deference in mean age was observed between two groups (glaucoma: 64.5 ± 14.4 years, non-glaucoma: 60.9 ± 14.1 years, P = 0.1156). Success rate of eye drop instillation was significantly lower (P = 0.0215) in glaucoma patients (30/78; 38.5%) than in non-glaucoma volunteers (48/85; 56.5%). The most frequent reason of instillation failure in glaucoma patients was touching the bulbar conjunctiva, cornea, eyelid or eyelashes with the tip of the bottle (29.5%). Multivariable logistic regression analysis identified lower corrected visual acuity (VA) (≤ 1.0; odds ratio [OR] = 0.20, 95% confidence interval [CI] 0.04-0.93, P = 0.0411), lower mean deviation (MD) (< -12 dB; OR = 0.20, 95% CI 0.05-0.86, P = 0.0307) and visual field defect (VFD) in the inferior hemifield (OR = 0.11, 95% CI 0.02-0.34, P < 0.001) to be significantly related to instillation failure in glaucoma patients.Success rate of eye drop instillation was significantly lower in glaucoma patients than in non-glaucoma volunteers. Corrected VA ≤ 1.0, MD < -12 dB and/or VFD in the inferior hemifield may be related to failure of eye drop instillation
    corecore