55 research outputs found

    Surface plasmon resonance imaging for affinity-based biosensors

    Get PDF
    SPR imaging (SPRi) is at the forefront of optical label-free and real-time detection. It offers the possibility of monitoring hundreds of biological interactions simultaneously and from the binding profiles, allows the estimation of the kinetic parameters of the interactions between the immobilised probes and the ligands in solution. We review the current state of development of SPRi technology and its application including commercially available SPRi instruments. Attention is also given to surface chemistries for biochip functionalisation and suitable approaches to improve sensitivity

    Clinical features and therapeutic management of patients admitted to Italian acute hospital psychiatric units: the PERSEO (psychiatric emergency study and epidemiology) survey

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The PERSEO study (psychiatric emergency study and epidemiology) is a naturalistic, observational clinical survey in Italian acute hospital psychiatric units, called SPDCs (Servizio Psichiatrico Diagnosi e Cura; in English, the psychiatric service for diagnosis and management). The aims of this paper are: (i) to describe the epidemiological and clinical characteristics of patients, including sociodemographic features, risk factors, life habits and psychiatric diagnoses; and (ii) to assess the clinical management, subjective wellbeing and attitudes toward medications.</p> <p>Methods</p> <p>A total of 62 SPDCs distributed throughout Italy participated in the study and 2521 patients were enrolled over the 5-month study period.</p> <p>Results</p> <p>Almost half of patients (46%) showed an aggressive behaviour at admission to ward, but they engaged more commonly in verbal aggression (38%), than in aggression toward other people (20%). A total of 78% of patients had a psychiatric diagnosis at admission, most frequently schizophrenia (36%), followed by depression (16%) and personality disorders (14%), and no relevant changes in the diagnoses pattern were observed during hospital stay. Benzodiazepines were the most commonly prescribed drugs, regardless of diagnosis, at all time points. Overall, up to 83% of patients were treated with neuroleptic drugs and up to 27% received more than one neuroleptic either during hospital stay or at discharge. Atypical and conventional antipsychotics were equally prescribed for schizophrenia (59 vs 65% during stay and 59 vs 60% at discharge), while atypical drugs were preferred in schizoaffective psychoses (72 vs 49% during stay and 70 vs 46% at discharge) and depression (41 vs 32% during stay and 44 vs 25% at discharge). Atypical neuroleptics were slightly preferred to conventional ones at hospital discharge (52 vs 44%). Polypharmacy was in general widely used. Patient attitudes toward medications were on average positive and self-reported compliance increased during hospital stay.</p> <p>Conclusion</p> <p>Results confirm the widespread use of antipsychotics and the increasing trend in atypical drugs prescription, in both psychiatric in- and outpatients.</p

    A novel optical biosensor format for the detection of clinically relevant TP53 mutations

    Get PDF
    The TP53 gene has been the subject of intense research since the realisation that inactivation of this gene is common to most cancer types. Numerous publications have linked TP53 mutations in general or at specific locations to patient prognosis and therapy response. The findings of many studies using general approaches such as immunohistochemistry or sequencing are contradictory. However, the detection of specific mutations, especially those occurring in the structurally important L2 and L3 zinc binding domains, which are the most common sites of TP53 mutations, have been linked to patient prognosis and more strongly to radiotherapy and chemotherapy resistance in several major cancers. In this study, the TI-SPR-1 surface plasmon resonance system and Texas Instruments Spreeta™ chips were used to develop a DNA biosensor based on thiolated probes complementary to these domains. The sensors were able to detect these mutations in both oligonucleotides and PCR products with normal and mutant TP53 DNA, but the difference in hybridisation signal was small. Preliminary experiments to enhance the signal using Escherichia coli mismatch repair proteins, MutS and single strand binding protein were carried out. It was found that MutS was unable to bind to mismatch oligonucleotides, but single strand binding protein was able to bind to single stranded probes, which had not hybridised to the target, resulting in a three-fold increase in the sensitivity of the biosensor. While further work needs to be carried out to optimise the system, these preliminary experiments indicate that the TI-SPR-1 can be used for the detection of clinically relevant mutations in the TP53 gene and that the sensitivity can be increased significantly using single strand binding protein. This system has a number of advantages over current mutation detection technologies, including lower cost, ease of sensor preparation and measurement procedures, technical simplicity and increased speed due to the lack of need for gel electrophoresis

    Detection of TP53 mutation using a portable Surface Plasmon Resonance DNA-based biosensor

    Get PDF
    A DNA-based Surface Plasmon Resonance (SPR) biosensor has been developed for the detection of TP53 mutation using the inexpensive and commercially available instrument, SPREETATM SPR-EVM-BT, from Texas Instruments. A direct immobilization procedure, based on the coupling of thiol-derivatised oligonucleotide probes (Probe-C6-SH) to bare gold sensor surfaces, was optimized using synthetic oligonucleotides. Hybridization reactions between the immobilized probe and a short sequence (26 mer) complementary, non-complementary and one point mutation DNA were then investigated. The main analytical parameters of the sensor system were studied in detail including selectivity, sensitivity, reproducibility and analysis time. Finally, the sensor system was successfully applied to polymerase chain reaction (PCR) amplified real samples, DNA extracted from both normal, wild type, (Jurkat) and mutated (Molt 4), carrying the mutation at codon 248 of the TP53 cell lines. The results obtained demonstrate that the DNA-based SPR biosensor was able to distinguish sequences present in the various samples that differ only by one base and hence it appears to be a strong candidate technique for the detection of gene mutation

    Approaches to allergy detection using aptasensors

    Get PDF
    1. Immunoglobulins and IgE Antibodies are glycoprotein molecules which are produced by plasma cells in response to an immunogen (1). They belong to a class of spherical proteins called globulins and are hence known as immunoglobulins (Igs). Their primary function is to mediate the host immune response by binding to antigens

    Protein-templated copper nanoclusters for fluorimetric determination of human serum albumin

    Get PDF
    Copper nanoclusters (CuNCs) are attractive for their unique optical properties, providing sensitive fluorescent detection of several kinds of targets even in complex matrices. Their ability in growing on suitable protein and nucleic acid templates make CuNCs efficient optical reporters to be exploited in bioanalysis. In this work, we report the specific and sensitive determination of human serum albumin (HSA) in human serum (HS) and urine via CuNCs fluorescence. HSA is the most abundant protein in plasma, and plays a key role in the early diagnosis of serious pathological conditions such as albuminuria and albuminemia. Recently, HSA has become clinically central also as a biomarker to assess severity, progression, and prognosis of various cancers. We report the controlled and reproducible growth of CuNCs directly on the target analyte, HSA, which results in a fine dose-dependent fluorescent emission at 405 nm. The protocol is optimized in water, and then applied to serum and urine specimens, without matrix pretreatment. The method linearly responds within the whole concentration of clinical interest, with a sensitivity of 1.8 ± 0.1 × 10-3 g L-1 and 0.62 ± 0.03 × 10-3 g L-1 in serum and urine, respectively, and excellent reproducibility (CVav% ca. 3% for both). The assay is designed to have a single protocol working for both matrices, with recovery of 95% (HS) and 96% (urine). The stability of the fluorescence after CuNCs formation was tested over 3 days, displaying good results (yet higher in urine than in serum)
    • …
    corecore