6,116 research outputs found

    Global water cycle

    Get PDF
    The primary objective is to determine the scope and interactions of the global water cycle with all components of the Earth system and to understand how it stimulates and regulates changes on both global and regional scales. The following subject areas are covered: (1) water vapor variability; (2) multi-phase water analysis; (3) diabatic heating; (4) MSU (Microwave Sounding Unit) temperature analysis; (5) Optimal precipitation and streamflow analysis; (6) CCM (Community Climate Model) hydrological cycle; (7) CCM1 climate sensitivity to lower boundary forcing; and (8) mesoscale modeling of atmosphere/surface interaction

    Old Wheat in a Tassel

    Get PDF

    The Impact of the Evolving Satellite Data Record on Reanalysis Water and Energy Fluxes During the Past 30 Years

    Get PDF
    Retrospective analyses (reanalyses) use a fixed assimilation model to take diverse observations and synthesize consistent, time-dependent fields of state variables and fluxes (e.g. temperature, moisture, momentum, turbulent and radiative fluxes). Because they offer data sets of these quantities at regular space / time intervals, atmospheric reanalyses have become a mainstay of the climate community for diagnostic purposes and for driving offline ocean and land models. Of course, one weakness of these data sets is the susceptibility of the flux products to uncertainties because of shortcomings in parameterized model physics. Another issue, perhaps less appreciated, is the fact that the discreet changes in the evolving observational system, particularly from satellite sensors, may also introduce artifacts in the time series of quantities. In this paper we examine the ability of the NASA MERRA (Modern Era Retrospective Analysis for Research and Applications) and other recent reanalyses to determine variability in the climate system over the satellite record (~ the last 30 years). In particular we highlight the effect on reanalyses of discontinuities at the junctures of the onset of passive microwave imaging (Special Sensor Microwave Imager) in late 1987 as well as improved sounding and imaging with the Advanced Microwave Sounding Unit, AMSU-A, in 1998. We examine these data sets from two perspectives. The first is the ability to capture modes of variability that have coherent spatial structure (e.g. ENSO events and near-decadal coupling to SST changes) and how these modes are contained within trends in near global averages of key quantities. Secondly, we consider diagnostics that measure the consistency in energetic scaling in the hydrologic cycle, particularly the fractional changes in column-integrated water vapor versus precipitation as they are coupled to radiative flux constraints. These results will be discussed in the context of implications for science objectives and priorities of the NASA Energy and Water Cycle Study, NEWS

    The Effect of Satellite Observing System Changes on MERRA Water and Energy Fluxes

    Get PDF
    Because reanalysis data sets offer state variables and fluxes at regular space / time intervals, atmospheric reanalyses have become a mainstay of the climate community for diagnostic purposes and for driving offline ocean and land models. Although one weakness of these data sets is the susceptibility of the flux products to uncertainties because of shortcomings in parameterized model physics, another issue, perhaps less appreciated, is the fact that continual but discreet changes in the evolving observational system, particularly from satellite sensors, may also introduce artifacts in the time series of quantities. In this paper we examine the ability of the NASA MERRA (Modern Era Retrospective Analysis for Research and Applications) and other recent reanalyses to determine variability in the climate system over the satellite record (approximately the last 30 years). In particular we highlight the effect on the reanalysis of discontinuities at the junctures of the onset of passive microwave imaging (Special Sensor Microwave Imager) in late 1987 as well as improved sounding and imaging with the Advanced Microwave Sounding Unit, AMSU-A, in 1998. We first examine MERRA fluxes from the perspective of how physical modes of variability (e.g. ENSO events, Pacific Decadal Variability) are contaminated by artificial step-like trends induced by the onset of new moisture data these two satellite observing systems. Secondly, we show how Redundancy Analysis, a statistical regression methodology, is effective in relating these artifact signals in the moisture and temperature analysis increments to their presence in the physical flux terms (e.g. precipitation, radiation). This procedure is shown to be effective greatly reducing the artificial trends in the flux quantities

    Nurses\u27 Alumnae Association Bulletin - Volume 17 Number 1

    Get PDF
    Alumnae Notes Committee Reports Digest of Alumnae Association Meetings Greetings from Miss Childs Greetings from the Educational Director Greetings from the President Graduation Awards - 1951 Jefferson\u27s New Hospital Addition Marriages Necrology Neurosurgery Department New Arrivals New Drugs Notes on the Cause of Leukemia Nursing Staff Saul Among the Prophets Staff Activities, 1951-1952 Students\u27 Corner The Hospital Pharmacy The Student Nurse Association of Pennsylvania White Haven and Barton Memorial Division

    Vitamin A Deficiency after Gastric Bypass Surgery: An Underreported Postoperative Complication

    Get PDF
    Introduction. Few data are available on vitamin A deficiency in the gastric bypass population. Methods. We performed a retrospective chart review of gastric bypass patients (n = 69, 74% female). The relationship between serum vitamin A concentration and markers of protein metabolism at 6-weeks and 1-year post-operative were assessed. Results. The average weight loss at 6-weeks and 1-year following surgery was 20.1 ± 9.1 kg and 44.1 ± 17.1 kg, respectively. At 6 weeks and 1 year after surgery, 35% and 18% of patients were vitamin A deficient, (<325 mcg/L). Similarly, 34% and 19% had low pre-albumin levels (<18 mg/dL), at these time intervals. Vitamin A directly correlated with pre-albumin levels at 6 weeks (r = 0.67, P < 0.001) and 1-year (r = 0.67,  P < 0.0001). There was no correlation between the roux limb length measurement and pre-albumin or vitamin A serum concentrations at these post-operative follow-ups. Vitamin A levels and markers of liver function testing were also unrelated. Conclusion. Vitamin A deficiency is common after bariatric surgery and is associated with a low serum concentration of pre-albumin. This fat-soluble vitamin should be measured in patients who have undergone gastric bypass surgery and deficiency should be suspected in those with evidence of protein-calorie malnutrition
    corecore