6 research outputs found

    Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i (R) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain

    Get PDF
    Urinary tract infections (UTI) are one of the most prevalent infections. A rapid and reliable screening method is useful to screen out negative samples. The objective of this study was to validate the Sysmex flow cytometer UF-1000i by evaluating its accuracy, linearity and carry-over; and define an optimal cut-off value to be used in routine practice in our hospital. For the validation of the UF-1000i cytometer, precision, linearity and carry-over were studied in samples with different counts of bacteria, leukocytes and erythrocytes. Between March and June 2016, urine samples were tested in the Clinical Microbiology Laboratory at University Miguel Servet Hospital, in Spain. Samples were analyzed with the Sysmex UF-1000i cytometer, and cultured. Growth of >= 10(5) CFUs/mL was considered positive. The validation study reveals that the precision in all the variables is acceptable; that there is a good linearity in the dilutions performed, obtaining values almost identical to those theoretically expected; and for the carry-over has practically null values. A total of 1, 220 urine specimens were included, of which 213 (17.4%) were culture positive. The optimal cut-off point of the bacteria-leukocyte combination was 138.8 bacteria or 119.8 leukocytes with an S and E of 95.3 and 70.4%, respectively. The UF-1000i cytometer is a valuable method to screen urine samples to effectively rule out UTI and, may contribute to the reduction of unnecessary urine cultures

    Comparing Two Automated Techniques for the Primary Screening-Out of Urine Culture

    Get PDF
    Urinary tract infection is the most common human infection with a high morbidity. In primary care and hospital services, conventional urine culture is a key part of infection diagnosis but results take at least 24 h. Therefore, a rapid and reliable screening method is still needed to discard negative samples as quickly as possible and to reduce the laboratory workload. In this aspect, this study aims to compare the diagnostic performance between Sysmex OF-1000i and FUS200 systems in comparison to urine culture as the gold standard. From March to June 2016, 1, 220 urine samples collected at the clinical microbiology laboratory of the "Miguel Servet" hospital were studied in parallel with both analysers, and some technical features were evaluated to select the ideal equipment. The most balanced cut-off values taking into account bacteria or leukocyte counts were 138 bacteria/mu L or 119.8 leukocyte/pl for the OF-1000i (95.3% SE and 70.4% SP), and 5.7 bacteria/mu L or 4.3 leukocyte/mu L for the FUS200 (95.8% SE and 44.4% SP). The reduction of cultured plates was 37.4% with the FUS200 and 58.3% with the UF-1000i. This study shows that both techniques improve the workflow in the laboratory, but the OF-1000i has the highest specificity at any sensitivity and the FUS200 needs a shorter processing time

    Global study of is6110 in a successful mycobacterium tuberculosis strain: Clues for deciphering its behavior and for its rapid detection

    Get PDF
    The Mycobacterium tuberculosis insertion sequence IS6110, besides being a very useful tool in molecular epidemiology, seems to have an impact on the biology of bacilli. In the present work, we mapped the 12 points of insertion of IS6110 in the genome of a successful strain named M. tuberculosis Zaragoza (which has been referred to as the MTZ strain). This strain, belonging to principal genetic group 3, caused a large unsuspected tuberculosis outbreak involving 85 patients in Zaragoza, Spain, in 2001 to 2004. The mapping of the points of insertion of IS6110 in the genome of the Zaragoza strain offers clues for a better understanding of the adaptability and virulence of M. tuberculosis. Surprisingly, the presence of one copy of IS6110 was found in Rv2286c, as was recently described for a successful Beijing sublineage. As a result of this analysis, a rapid method for detecting this particular M. tuberculosis strain has been designed

    Body mass index and complications following major gastrointestinal surgery: A prospective, international cohort study and meta-analysis

    No full text
    Aim Previous studies reported conflicting evidence on the effects of obesity on outcomes after gastrointestinal surgery. The aims of this study were to explore the relationship of obesity with major postoperative complications in an international cohort and to present a metaanalysis of all available prospective data. Methods This prospective, multicentre study included adults undergoing both elective and emergency gastrointestinal resection, reversal of stoma or formation of stoma. The primary end-point was 30-day major complications (Clavien–Dindo Grades III–V). A systematic search was undertaken for studies assessing the relationship between obesity and major complications after gastrointestinal surgery. Individual patient meta-analysis was used to analyse pooled results. Results This study included 2519 patients across 127 centres, of whom 560 (22.2%) were obese. Unadjusted major complication rates were lower in obese vs normal weight patients (13.0% vs 16.2%, respectively), but this did not reach statistical significance (P = 0.863) on multivariate analysis for patients having surgery for either malignant or benign conditions. Individual patient meta-analysis demonstrated that obese patients undergoing surgery formalignancy were at increased risk of major complications (OR 2.10, 95% CI 1.49–2.96, P < 0.001), whereas obese patients undergoing surgery for benign indications were at decreased risk (OR 0.59, 95% CI 0.46–0.75, P < 0.001) compared to normal weight patients. Conclusions In our international data, obesity was not found to be associated with major complications following gastrointestinal surgery. Meta-analysis of available prospective data made a novel finding of obesity being associated with different outcomes depending on whether patients were undergoing surgery for benign or malignant disease

    Safety of hospital discharge before return of bowel function after elective colorectal surgery

    No full text
    Background: Ileus is common after colorectal surgery and is associated with an increased risk of postoperative complications. Identifying features of normal bowel recovery and the appropriateness for hospital discharge is challenging. This study explored the safety of hospital discharge before the return of bowel function. Methods: A prospective, multicentre cohort study was undertaken across an international collaborative network. Adult patients undergoing elective colorectal resection between January and April 2018 were included. The main outcome of interest was readmission to hospital within 30 days of surgery. The impact of discharge timing according to the return of bowel function was explored using multivariable regression analysis. Other outcomes were postoperative complications within 30 days of surgery, measured using the Clavien\u2013Dindo classification system. Results: A total of 3288 patients were included in the analysis, of whom 301 (9\ub72 per cent) were discharged before the return of bowel function. The median duration of hospital stay for patients discharged before and after return of bowel function was 5 (i.q.r. 4\u20137) and 7 (6\u20138) days respectively (P &lt; 0\ub7001). There were no significant differences in rates of readmission between these groups (6\ub76 versus 8\ub70 per cent; P = 0\ub7499), and this remained the case after multivariable adjustment for baseline differences (odds ratio 0\ub790, 95 per cent c.i. 0\ub755 to 1\ub746; P = 0\ub7659). Rates of postoperative complications were also similar in those discharged before versus after return of bowel function (minor: 34\ub77 versus 39\ub75 per cent; major 3\ub73 versus 3\ub74 per cent; P = 0\ub7110). Conclusion: Discharge before return of bowel function after elective colorectal surgery appears to be safe in appropriately selected patients
    corecore