14 research outputs found
Recommended from our members
SINGLE MOLECULE STUDIES OF A SHORT RNA
The material related with orientation of Cyanine dyes and their behavior at the ends of duplex RNA is also documented in [110]. Cyanine dyes are widely used to study the folding and structural transformations of nucleic acids using fluorescence resonance energy transfer (FRET). The extent to which FRET can be used to extract inter- and intra-molecular distances has been the subject of considerable debate in the literature; the contribution of dye and linker dynamics to the observed FRET signal is particularly troublesome. We used molecular dynamics (MD) simulations to study the dynamics of the indocarbocyanine dyes Cy3 and Cy5 attached variously to the 3 or 5 terminal bases of a 16 base-pair RNA duplex. We then used Monte Carlo modeling of dye photophysics to predict the results of single-molecule sensitive FRET measurements of these same molecules. Our results show that the average value of FRET depends on both the terminal base and on the linker position. In particular, 3 attached dyes typically explore a wide region of configuration space and the relative orientation factor, κ2, has a distribution that approaches that of free- rotators. This is in contrast to 5 attached dyes, which spend a significant fraction of their time in one or more configurations that are effectively stacked on the ends of the RNA duplex. The presence of distinct dye configurations for 5 attached dyes is consistent with observations made by others of multiple fluorescence lifetimes of Cy3 on nucleic acids. While FRET is frequently used as a molecular “ruler” to measure intramolecular distances, the unambiguous measurement of distances typically relies on the assumption that the rotational degrees of freedom of the dyes can be averaged out, and that the donor lifetime in the absence of the acceptor is a constant. We demonstrate that even for the relatively free 3 attached dyes, the correlation time of κ2 is still too long to justify the use of a free-rotation approximation. We further explore the consequences of multiple donor lifetimes on the predicted value of FRET.
While providing detailed information about the individual members of a molecular ensemble, FRET technique is always limited by fluorophore brightness and stability. In the case of diffusing molecules, the experiment is further limited by the number of photons that can be collected during the time it takes for a molecule to diffuse across the detection volume. To maximize the number of photons it is common to either increase the detection volume at the expense of increased background, or increase the diffusion time by adding glycerol or sucrose to increase viscosity. As an alternative to current methods, here we demonstrated that water in oil nano-emulsions in perfluorinated compounds FC40 and FC77 can be used to confine biomolecules which results a dramatic increase in signal to noise ratios. To efficiently use these attoliter volume (130 nm radius) aqueous containers, their characterization in terms of physical and chemical properties is necessary for both understanding the droplet environment and making better statements for single molecule experiment results within them. Characterization in terms of size is not an easy task because droplet system is a macroemulsion, so that droplets are kinetically stable.
Therefore in addition to conventional dynamic light scattering (DLS) measurements, we proposed a new method to measure droplet sizes using Mie scattering . The method was originally used in atmospheric physics and medical imaging and in our knowledge it was the first time of its use on an emulsion system. We also measured the average pH within droplets by this new method using an absorptive dye (bromothymol blue). These measurements in combination with the emission measurements using another pH sensitive dye (fluorescein) showed that the droplet environment is acidic. Our initial attempts for changing the pH by adding a strong base to bulk aqueous samples prior to emulsification were succesful but the interpretation of result were not accurate because of working pH range of pH indicators.
Single molecule experiments within attoliter aqueous droplets provided supporting results for the low pH argument. We have seen that Cy3 only labelled duplex RNA ,in bulk experiments, was sensitive to ambient pH in the solution. This sensitivity appeared as a shift in the mean value of proximity histograms. The mean value of proximity ratio histograms at low pH (less than pH 7) was similar to the mean value of proximity ratio histograms we observed in droplet data. In addition, using photon counting histograms we identified a third brighter species in low pH solution data and in droplet data. All these materials related with single molecule works within droplets is also documented in [111]. In our knowledge, there is no analytical function given in the literature for the autocorrelation function of fluorescence correlation spectroscopy (FCS) data within droplets. Thus, we put effort for simulating the FCS of droplets. Although, this ap- proach didn’t provide us an analytical form, it was helpful for further understanding the internal environment of droplets. As a result of simulations, we observed that diffusion time within droplets long (on the order of a millisecond). In addition, we were able identify the source of different correlation times observed in FCS experimental data
Single-Molecule-Sensitive FRET in Freely-Diffusing Attoliter Droplets
Fluorescence resonance energy transfer (FRET) from individual, dye-labeled
RNA molecules confined in freely-diffusing attoliter-volume aqueous droplets is
carefully compared to FRET from unconfined RNA in solution. The use of
freely-diffusing droplets is a remarkably simple and high-throughput technique
that facilitates a substantial increase in signal-to-noise for
single-molecular-pair FRET measurements. We show that there can be dramatic
differences between FRET in solution and in droplets, which we attribute
primarily to an altered pH in the confining environment. We also demonstrate
that a sufficient concentration of a non-ionic surfactant mitigates this effect
and restores FRET to its neutral-pH solution value. At low surfactant levels,
even accounting for pH, we observe differences between the distribution of FRET
values in solution and in droplets which remain unexplained. Our results will
facilitate the use of nanoemulsion droplets as attoliter volume reactors for
use in biophysical and biochemical assays, and also in applications such as
protein crystallization or nanoparticle synthesis, where careful attention to
the pH of the confined phase is required.Comment: Twenty-three pages, 3 figures, one table, plus supporting information
with additional figures and table
Perbedaan Asupan Lemak, Lingkar Pinggang dan Persentase Lemak Tubuh pada Wanita Dislipidemia dan Non Dislipidemia
Differences of fat intake, waist circumference and percentage of bodt fat in dyslipidemia and non dyslipidemia adult women: Heart disease is the leading cause of death in several countries in the world . One of the major risk factors for heart disease is dyslipidemia . Dyslipidemia is a disorder of lipid metabolism characterized by an increase or decrease in plasma lipid fractions . Dyslipidemia has a strong relationship with the occurrence of central obesity . The purpose of this study was to analyze differences in the intake of fat , waist circumference and body fat percentage in dyslipidemia and non dyslipidemia adult women. This research is analytic study with cross sectional approach . The population in this study were adult women who examined their lipid profile in December 2013 in the Clinical Laboratory Cito Indraprasta Semarang . The total sample was 32 people . Independent test analysis of the differences using t-test for variables waist circumference and Mann Whitney test for variable fat intake and body fat percentage to 95 % and a significance level of 5% error. The results showed 17 adult women ( 53.1 % ) and 15 female adult dyslipidemia ( 46.9 % ) non- dyslipidemia. Average intake of fat, waist circumference and percentage body fat in adult women dyslipidemia higher than non dyslipidemia in adult women. Analysis of statistical tests showed difference in fat intake , waist circumference and body fat percentage in women adult dyslipidemia and non dyslipidemia (p value, respectively p = 0.002, p = 0.0001 and p = 0.0001