    Non-destructively differentiating the roles of creep, wear and oxidation in long-term in vivo exposed polyethylene cups

    Get PDF
    Wear of polyethylene acetabular cups in patients of total hip arthroplasty is routinely deduced from the penetration of the femoral head into the acetabular liner as observed in the radiographs. However, the linear penetration thus measured represents the cumulative contribution of two components, one due to wear, and the other due to creep or irreversible deformation of the polyethylene structure. The erroneous attribution to wear of the entire penetration displacement of the head in the cup might lead to misinterpretation of the actual performance of acetabular cups. The aim of this study was to quantify the head displacement components due to wear and to creep, as they occur in vivo in acetabular cups, and to relate them to the oxidation state of the material by means of advanced Raman spectroscopy procedures. Throughout the investigation, we compared the behaviors on the molecular scale of acetabular cups subjected to different sterilization methods (i.e., gamma-irradiation and ethylene oxide treatment). (C) Koninklijke Brill NV, Leiden, 201

    The utility of three-dimensional dynamic contrast-enhanced

    Get PDF
    Aneurysmal bone cysts (ABCs) are classified as bone-related lesions based on the 2005 World Health Organization histological classification of odontogenic tumors. Most ABCs are diagnosed using a combination of conventional radiography, computed tomography, magnetic resonance imaging (MRI), and digital subtraction angiography. ABCs should be differentiated from true cysts or other pseudocysts because their treatment is different. Additionally, unlike other cysts, ABCs pose a hemorrhagic risk in surgery; thus, preoperative evaluation of intralesional blood flow is required. Here we report a case of a mandibular ABC in a 39-year-old woman and focus on its dynamic contrast-enhanced MRI (DCE-MRI) features. On DCE-MRI, the lesion was divided into two areas according to the enhancement pattern: the blood-pooling and blood-flow areas. The series of DCE-MR images of the blood-pooling area showed marked enhancement of the margin, but no enhancement in the inner part of the cavity. Additionally, the time-signal intensity curve (TIC) demonstrated no change in the signal intensity (SI) until approximately 15 min after gadolinium-diethylenetriamine penta-acetic acid (Gd-DTPA) administration. In contrast, the series of DCE-MR images of the blood-flow area exhibited marked enhancement in the cyst cavity in the early phase. The TIC showed a rapid increase in SI in the early phase, followed by a rapid decrease until 150 s, and finally a gradual decrease until approximately 15 min after Gd-DTPA administration. Thus, in the current patient, preoperative DCE-MRI clearly delineated the vessel-rich area within the lesion

    Application of dynamic contrast-enhanced MRI to differentiate malignant lymphoma from squamous cell carcinoma in the head and neck

    Get PDF
    Because malignant lymphoma, the second most common malignant tumor of the head and neck, and squamous cell carcinoma (SCC), the most common malignant tumor of the head and neck, require different treatments, it is important to be able to differentiate them. In the present study, we attempted to differentiate malignant lymphomas from SCCs using dynamic contrast-enhanced MRI (DCE-MRI). Seventeen lesions (in 8 cases) of malignant lymphoma and 30 cases of SCC were compared by DCE-MRI. Thirteen of 17 malignant lymphomas (76.5%) showed the maximum contrast index (CI) at 90–180 s, while 26 of 30 SCCs (86.7%) showed the maximum CI at a much faster 60–105 s. There was a statistically significant difference between SCC and malignant lymphoma in the time needed reach the maximum CI (p=0.0177). There was also significant difference between SCC and malignant lymphoma in their maximum CIs (p&#60;0.001), with the maximum CIs of 29/30 SCCs (96.7%) above 2.0, while 12/17 malignant lymphomas (70.6%) showed CIs of less than 2.0. We consider these findings to be useful for distinguishing lymphomas from SCCs.</p

    Diagnostic value of dynamic contrast-enhanced MRI for unilocular cystic-type ameloblastomas with homogeneously bright high signal intensity on T2-weighted or STIR MR images

    Get PDF
    Typical MR images of ameloblastomas on T2-weighted image (WI) or short inversion time inversion-recovery (STIR) show multiple bright high-signal-intensity loci on a high-signal-intensity background. Unilocular cystic-type ameloblastomas show homogeneously bright high signal intensity on T2WI or STIR as a water-like signal intensity. Therefore, it is difficult to distinguish unilocular cystic-type ameloblastoma from other cystic lesions such as keratocystic odontogenic tumors, radicular cysts (residual cysts) and dentigerous cysts only on the basis of MRI signal intensity. In the present study, we evaluated whether contrast-enhanced (CE)-T1WI and dynamic CE-MRI (DCE-MRI) could provide additional information for differential diagnosis in unilocular cystic-type ameloblastoma. Images from 12 cases of suspected unilocular cystic-type ameloblastoma were evaluated in the present study. Of them, 5 had areas suspected of indicating a solid component on T1WI and T2WI (or STIR). Ten had undergone additional CE-T1WI and DCE-MRI. On 5 of 10 cases of CE-T1WI, a tiny enhancement area was detected. On 6 of 10 DCE-images, a time-course enhanced area which was suspected to be a solid component was detected. CE-T1WI was helpful in the diagnosis of ameloblastoma because the tiny enhanced areas were taken to indicate possible solid components. Moreover, the rim-enhancement area on CE-T1WI could be divided into small regions of interest, and some of these showed slightly increased enhancement on DCE-MRI, which was taken to indicate a solid component and/or intramural nodule with focal invasion of ameloblastoma tissue. DCE-MRIs of the four remaining cases, which provided no clues to the diagnosis of ameloblastoma in the manner of the above descriptions, showed thicker rim enhancement than odontogenic cysts. Thus, CE-T1WI and DCE-MRI were helpful in the differential diagnosis of unilocular cystic-type ameloblastomas with homogeneously bright high signal intensity on T2WI or STIR

    In Vitro Assessment of Factors Affecting the Apparent Diffusion Coefficient of Jurkat Cells Using Bio-phantoms

    Get PDF
    It is well known that many tumor tissues show lower apparent diffusion coefficient (ADC) values, and that several factors are involved in the reduction of ADC values. The aim of this study was to clarify how much each factor contributes to decreases in ADC values. We investigate the roles of cell density, extracellular space, intracellular factors, apoptosis and necrosis in ADC values using bio-phantoms. The ADC values of bio-phantoms, in which Jurkat cells were encapsulated by gellan gum, were measured by a 1.5-Tesla magnetic resonance imaging device with constant diffusion time of 30sec. Heating at 42℃ was used to induce apoptosis while heating at 48℃ was used to induce necrosis. Cell death after heating was evaluated by flow cytometric analysis and electron microscopy. The ADC values of bio-phantoms including non-heated cells decreased linearly with increases in cell density, and showed a steep decline when the distance between cells became less than 3μm. The analysis of ADC values of cells after destruction of cellular structures by sonication suggested that approximately two-thirds of the ADC values of cells originate from their cellular structures. The ADC values of bio-phantoms including necrotic cells increased while those including apoptotic cells decreased. This study quantitatively clarified the role of the cellular factors and the extracellular space in determining the ADC values produced by tumor cells. The intermediate diffusion time of 30msec might be optimal to distinguish between apoptosis and necrosis

    Assessment of MRI and dynamic contrast-enhanced MRI in the differential diagnosis of adenomatoid odontogenic tumor

    Get PDF
    The radiographical differentiation of adenomatoid odontogenic tumor (AOT) from dentigerous cysts, calcifying odontogenic cysts, calcifying epithelial odontogenic tumors, odontogenic keratocysts, and amelobastomas is sometimes difficult. We attempted to differentiate AOT from other lesions similar to AOT in radiographic findings using MRI. The MRI features of AOT in our 3 cases included homogeneous low SI in the cystic portion and homogeneous intermediate SI in the solid portion on T1WI, homogeneous high SI in the cystic portion and intermediate to slightly high SI in the solid portion on T2WI, and enhancement of only the solid portion on CE-T1WI although non of the sequences included SI of calcifications. The contrast index curves in the 3 cases of AOT showed a gradual increase to 300 s, which signified a benign tumor. These MRI features were characteristic features of AOT and might be a basis for differentiating AOT from the above possible lesions in radiographic examinations.</p

    A Single Nucleotide Polymorphism within the Novel Sex-Linked Testis-Specific Retrotransposed PGAM4 Gene Influences Human Male Fertility

    Get PDF
    The development of novel fertilization treatments, including in vitro fertilization and intracytoplasmic injection, has made pregnancy possible regardless of the level of activity of the spermatozoa; however, the etiology of male-factor infertility is poorly understood. Multiple studies, primarily through the use of transgenic animals, have contributed to a list of candidate genes that may affect male infertility in humans. We examined single nucleotide polymorphisms (SNPs) as a cause of male infertility in an analysis of spermatogenesis-specific genes.We carried out the prevalence of SNPs in the coding region of phosphoglycerate mutase 4 (PGAM4) on the X chromosome by the direct sequencing of PCR-amplified DNA from male patients. Using RT-PCR and western blot analyses, we identified that PGAM4 is a functional retrogene that is expressed predominantly in the testes and is associated with male infertility. PGAM4 is expressed in post-meiotic stages, including spermatids and spermatozoa in the testes, and the principal piece of the flagellum and acrosome in ejaculated spermatozoa. A case-control study revealed that 4.5% of infertile patients carry the G75C polymorphism, which causes an amino acid substitution in the encoded protein. Furthermore, an assay for enzymatic activity demonstrated that this polymorphism decreases the enzyme's activity both in vitro and in vivo.These results suggest that PGAM4, an X-linked retrogene, is a fundamental gene in human male reproduction and may escape meiotic sex chromosome inactivation. These findings provide fresh insight into elucidating the mechanisms of male infertility

    Clinical Study Cement Removal from the Femur Using the ROBODOC System in Revision Total Hip Arthroplasty

    No full text
    Introduction. The perforation and fracture of the femur during the removal of bone cement in revision total hip arthroplasty (THA) are serious complications. The ROBODOC system has been designed to selectively remove bone cement from the femoral canal, but results have not been reported yet. The purpose of our study was to evaluate the clinical and radiographic results of revision THA using the ROBODOC system for cement removal. Materials and Methods. The subjects comprised 19 patients who underwent revision THA using the ROBODOC system. The minimum duration of follow-up was 76 months (median, 109 months; range, 76-150 months). The extent of remaining bone cement on postoperative radiography, timing of weight bearing, and the complications were evaluated. Results. The mean Merle d&apos; Aubigne and Postel score increased from 10 points preoperatively to 14 points by final follow-up. Bone cement was completely removed in all cases. Full weight bearing was possible within 1 week after surgery in 9 of the 19 cases and within 2 months in all remaining cases. No instances of perforation or fracture of the femur were encountered. Conclusions. Bone cement could be safely removed using the ROBODOC system, and no serious complications occurred. Full weight bearing was achieved early in the postoperative course because of circumferential preservation of the femoral cortex